SIEMENS 7KM2111-1BA00-3AA0 7KM2111-1BA00-3AA0 SIEMENS SENTRON, measuring device, 7KM PAC3200, LCD, L-L: 500 V, L-N: 289 V, 5 A, 3-phase.. View larger
Images are for illustrative purposes only. Please refer to data sheet for details

7KM2111-1BA00-3AA0 SIEMENS SENTRON, measuring device, 7KM PAC3200, LCD, L-L: 500 V, L-N: 289 V, 5 A, 3-phase..

7KM2111-1BA00-3AA0

21111

SIEMENS

1 Pcs.

SENTRON, measuring device, 7KM PAC3200, LCD, L-L: 500 V, L-N: 289 V, 5 A, 3-phase, Modbus TCP, optional Modbus RTU / PROFINET / PROFIBUS, apparent/ active/reactive energy, class 0.5 acc. to IEC61557-12 or class 0.5s acc. to IEC62053-22, ext-low volt. pwr sup. unit DC, DC 22 ... 65 V +/- 10%, screw terminals

Automation > Multifunction measuring instrument
SENTRON PAC network analyzers. Energy Management Software

Product condition, packaging, certifications and applicable manufacturer warranty terms are confirmed with the quotation.

Request a Quote

Pricing and availability are confirmed for each enquiry. Add your required quantity to begin.

No account, online checkout or payment is required.

More info

ETIM: EC002301 - Multifunction measuring instrument

Value Unit
Ampere meter (EF006555) false
Blind power meter (EF006556) false
With rotational speed meter (EF006557) false
Frequency meter (EF006558) false
Pulse counter (EF006559) false
Voltmeter (EF006560) false
Effective power measurement device (EF006561) false


SENTRON, measuring device, 7KM PAC3200, LCD, L-L: 500 V, L-N: 289 V, 5 A, 3-phase, Modbus TCP, optional Modbus RTU / PROFINET / PROFIBUS, apparent/ active/reactive energy, class 0.5 acc. to IEC61557-12 or class 0.5s acc. to IEC62053-22, ext-low volt. pwr sup. unit DC, DC 22 ... 65 V +/- 10%, screw terminals
Model
product brand nameSENTRON
Product designation7KM PAC3200
Design of the productbasic
Product type designationMeasuring instrument
Type of measured value detectioncomplete
design of the power supplyExtra-low voltage power supply unit
General technical data
Cutout width92 mm
Cutout height92 mm
Size of Power Monitoring Device / company-specificsize 96
Operating mode for measured value detection
● automatic line frequency detectionYes
● set at 50 HzNo
● set to 60 HzNo
Pulse duration
● initial value30 ms
● Full-scale value500 ms
Voltage curveSinusoidal or distorted
Measurable line frequency / initial value45 Hz
Measurable line frequency / Full-scale value65 Hz
Measuring procedure / for voltage measurementRMS
MTBF185.8 y
Reference code / acc. to DIN 40719 extended according to IEC 204-2 / acc. to IEC 750P
Supply voltage
Type of voltage / of the supply voltageDC
Measuring category / for supply voltageCATIII
Apparent power consumption
● with expansion module / maximum8 V·A
● without expansion module / typical6 V·A
Relative symmetrical tolerance / of the supply voltage10 %
Protection class
● protection class IP / on the frontIP65
● Protection class IP / Rear sideIP20
Operating resource protection class / when installedII
Current
Measurable current
● 1 / at AC / Rated value1 A
● 2 / at AC / Rated value5 A
Suitability
Suitability for operationInstallation in stationary control panels in closed rooms
adjustable time period / minimum10 ms
Product function
● product function / reactive power measurementYes
● product function / frequency measurementYes
● product function / pulse measurementYes
● product function / voltage measurementYes
● product function / current measurementYes
● product function / active power measurementYes
Display and operation
design of the displayLCD
number of keys4
Color / of the background of the displaywhite
National language / on the display screen / is supportedger, en, fr, spa, ita, por, tur, chi
Horizontal image resolution128
Vertical screen resolution96
Refresh time / on display
● minimum0.33 s
● maximum3 s
Communication
Refresh time / at the interface
● minimum0.33 s
● maximum1 s
Number of interfaces / acc. to Fast Ethernet1
Design of cable / connectable / Twisted pairYes
Protocol
● at the Ethernet interface / is supportedMODBUS TCP
● is supportedModbus TCP
Transfer rate
● minimum10 000 kbit/s
● maximum10 000 kbit/s
Fault limits
Reference condition / for metering accuracyAcc. to IEC62053-22 and IEC62053-23
● Formula for relative total measurement inaccuracy / for measured variable reactive energyClass 2 according to IEC61557-12 and/or IEC62053-23
● Formula for relative total measurement inaccuracy / for measured variable output+/- 0,5 %
● Formula for relative total measurement inaccuracy / for measured variable output factor+/- 0,5 %
● Formula for relative total measurement inaccuracy / for measured variable voltage+/- 0,3 %
● Formula for relative total measurement inaccuracy / for measured variable current+/- 0,2 %
● Formula for relative total measurement inaccuracy / for measured variable active energyCl. 0.5 acc. to... IEC62053-22
Inputs Outputs
Input voltage / at digital input
● initial value for signal<1>-recognition13 V
● at DC / rated value24 V
● Full-scale value for signal<0> recognition8 V
number of digital outputs1
number of digital inputs1
Digital output versionswitching or pulse output function
Input current / at digital input
● for signal <1>7 mA
Output current
● at digital output / with signal <0> / maximum0.2 mA
● at digital output / for signal <1> / minimum10 mA
● at digital output / for signal <1> / maximum27 mA
● at the digital outputs / at DC / maximum100 mA
Output delay / at digital output
● for signal <0> to <1> / maximum5 ms
● for signal <1> to <0> / maximum5 ms
Operating voltage / as output voltage / at DC / maximum permissible30 V
property of the output / short-circuit proofYes
Input delay time / at digital input
● for signal <0> to <1> / maximum5 ms
● for signal <1> to <0> / maximum5 ms
Internal resistance / at the digital outputs55 Ω
Measuring category / for digital signalsCATII
Switching frequency / at digital output / maximum17 Hz
Transfer rate
● 1 / for fast Ethernet10 Mbit/s
Measuring inputs
Outer conductors and neutral conductors internal resistance / for voltage measurement1.05 MΩ
Measurable supply voltage
● between (PE)N and L / at AC / minimum40 V
● between (PE)N and L / at AC / maximum346 V
● between (PE)N and L / at AC / maximum rated value289 V
● between the outer conductors / at AC / minimum70 V
● between the outer conductors / at AC / maximum600 V
● between the outer conductors / at AC / maximum rated value500 V
Current measuring range extension / with external current transformersYes
Measuring category / for voltage measurementCATIII
Supply voltage / between the outer conductors / at AC / maximum permissible600 V
Consumed active power / for current measurement / per phase115 mW
Continuous current / at AC / maximum permissible10 A
Measuring category / for current measurementCATIII
Zero-point suppression / for current measurement0,1 ... 10 %
Relative measurable current / at AC
● minimum1 %
● maximum120 %
Measuring procedure / for current measurementTRMS
Connections
Type of connectable conductor cross-sections / at the digital inputs
● at AWG conductors / solid2x 24 ... 18
● solid1x (0.2 ... 2.5 mm²), 2x (0.2 ... 1.0 mm²)
● finely stranded / with core end processing1x (0.25 ... 2.5 mm²), 2x (0.25 ... 1.0 mm²)
Type of connectable conductor cross-sections / at the digital outputs
● at AWG conductors / solid2x 24 ... 18
● solid1x (0.2 ... 2.5 mm²), 2x (0.2 ... 1.0 mm²)
● finely stranded / with core end processing1x (0.25 ... 2.5 mm²), 2x (0.25 ... 1.0 mm²)
Type of connectable conductor cross-sections / at the inputs for supply voltage
● at AWG conductors / solid2x 20 to 14
● solid1x (0.5 ... 4 mm²), 2x (0.5 ... 2.5 mm²)
● finely stranded / with core end processing1x (0.5 ... 2.5 mm²), 2x (0.5 ... 1.5 mm²)
Type of connectable conductor cross-sections
● at the measurement inputs for voltage / at AWG conductors / solid2x 20 to 14
● at the measurement inputs for voltage / solid1x (0.5 ... 4 mm²), 2x (0.5 ... 2.5 mm²)
● at the measurement inputs for voltage / finely stranded / with core end processing1x (0.5 ... 2.5 mm²), 2x (0.5 ... 1.5 mm²)
● at the measurement inputs for current / at AWG conductors / solid2x 20 to 14
● at the measurement inputs for current / solid1x (0.5 ... 4 mm²), 2x (0.5 ... 2.5 mm²)
● at the measurement inputs for current / finely stranded / with core end processing1x (0.5 ... 2.5 mm²), 2x (0.5 ... 1.5 mm²)
Type of electrical connection
● at the measurement inputs for voltagescrew-type terminals
Mechanical Design
Height96 mm
Height / of the display54 mm
Width96 mm
● Width / of the display72 mm
Depth56 mm
installation depth51 mm
Mounting type / panel mountingYes
mounting positionvertical
net weight459 g
Environmental conditions
Installation altitude / at height above sea level / maximum2 000 m
Standard
● for EMC for industrial sectorIEC 61000-6-2 respectively IEC 61326-1:2005, table 2
● for EMC against unloadingIEC 61000-4-2: 2001-04
● for EMC against high frequency fieldsIEC 61000-4-3: 2006-02
● for EMC against conducted LF disturbance variables (industry)IEC 61000-6-4, Group 1 Klasse A / CISPR11 Gruppe 1 Klasse A FCC Part 15 Subpart B Class A
● for EMC against conducted disturbance variables via HF fieldsIEC 61000-4-6: 2001-12
● for EMC against magnetic fields with power engineering frequenciesIEC 61000-4-8: 2001-03
● for EMC against quick, transient electrical disturbancesIEC 61000-4-4: 2005-07
● for EMC against voltage drops and interruptionsIEC 61000-4-11: 2004-03
● for EMC against surge voltagesIEC 61000-4-5: 2001-12
● for free fallIEC 60068-2-32: 1975
● for pulse emitteraccording to IEC62053-31
● for cyclic, environmental damp heat checkIEC 60068-2-30
● for environmental coldness checkIEC 60068-2-1
● for environmental dry heat checkIEC 60068-2-2
Relative humidity / at 25 °C / without condensation / during operation
● minimum5 %
● maximum95 %
Ambient temperature / during operation
● minimum-10 °C
● maximum55 °C
Ambient temperature / during storage
● minimum-25 °C
● maximum70 °C
Certificates
● Certificate of suitability / as EC declaration of conformityIEC 61010-1: 2001 (2nd Ed.) with Corr. 1, EN 61010-1: 2001 (2nd Ed.) and DIN EN 61010-1:2002 with "Berichtigung 1"
● Certificate of suitability / as approval for CanadaUL 61010-1, 2nd Ed. CAN/CSA-C22.2 NO. 61010-1-04
● Certificate of suitability / as approval for USAUL 61010-1, 2nd Ed. CAN/CSA-C22.2 NO. 61010-1-04
● reference code / acc. to DIN EN 61346-2P
General Product ApprovalDeclaration of Conformityother

UL

EC/EU-Declaration of Conformity

Confirmation

Manufacturer Declaration

Further information
Information- and Downloadcenter (Catalogs, Brochures,…)
Industry Mall (Online ordering system)
Service&Support (Manuals, Certificates, Characteristics, FAQs,...)
Image database (product images, 2D dimension drawings, 3D models, device circuit diagrams, ...)
CAx-Online-Generator
Tender specifications


Product
Article Number (Market Facing Number)7KM2111-1BA00-3AA0
Product DescriptionSENTRON, measuring device, 7KM PAC3200, LCD, L-L: 500 V, L-N: 289 V, 5 A, 3-phase, Modbus TCP, optional Modbus RTU / PROFINET / PROFIBUS, apparent/ active/reactive energy, class 0.5 acc. to IEC61557-12 or class 0.5s acc. to IEC62053-22, ext-low volt. pwr sup. unit DC, DC 22 ... 65 V +/- 10%, screw terminals
Product family7KM PAC Measuring Devices
Product Lifecycle (PLM)PM300:Active Product
Price data
Price Group15N
Surcharge for Raw MaterialsNone
Metal FactorNone
Delivery information
Export Control RegulationsAL : N / ECCN : EAR99
Standard lead time ex-works14 Day/Days
Net Weight (kg)0,419 Kg
Product Dimensions (W x L x H)Not available
Packaging Dimension110,00 x 130,00 x 80,00
Package size unit of measureMM
Quantity Unit1 Piece
Packaging Quantity1
Additional Product Information
EAN4011209774421
UPC783087924277
Commodity Code90303100
LKZ_FDB/ CatalogIDLV10.1
Product Group5308
Group CodeP360
Country of originHungary
Compliance with the substance restrictions according to RoHS directiveSince: 01.03.2008
Product classA: Standard product which is a stock item could be returned within the returns guidelines/period.
WEEE (2012/19/EU) Take-Back ObligationYes
REACH Art. 33 Duty to inform according to the current list of candidates

Information obligation imposed by Article 33, REACH Regulation: This product includes one or several articles in which the following substance of the candidate list is contained in concentrations higher than 0,1% weight by weight (w/w):

Lead monoxide (lead oxide)

Based on the information currently available, we assume that these substances do not pose any risk if the articles are used as intended (including disposal). Please also refer to product documentation.

Classifications
VersionClassification
eClass627-20-03-01
eClass7.127-20-03-01
eClass827-20-03-01
eClass927-20-03-01
eClass9.127-20-03-01
ETIM4EC002301
ETIM5EC002301
ETIM6EC002301
ETIM7EC002301
UNSPSC1441-11-37-08
UNSPSC1541-11-37-08

Product Datasheet

Electrica Online Product Datasheet Prepared from the current product description, catalog data and structured technical attributes.