View larger
6SL3246-0BA22-1PA0 SIEMENS SINAMICS G120 CONTROL UNIT CU250S-2 DP INTEGRIERT PROFIBUS SUPPORT OF VECTOR CONT..
6SL3246-0BA22-1PA0
32460
SIEMENS
1 Pcs.
Automation > Frequency converter less than 1 kV
SINAMICS G120 Control Units
Product condition, packaging, certifications and applicable manufacturer warranty terms are confirmed with the quotation.
Request a Quote
Pricing and availability are confirmed for each enquiry. Send this part and we will reply with price and lead time.
Request QuoteProduct Overview
6SL3246-0BA22-1PA0 Siemens control unit manages modular drive systems, processing parameters and communication protocols for industrial motion control. Control units coordinate feedback loops and operational commands within complex automation architectures.
Pricing, availability and lead time are confirmed per enquiry through an RFQ.
- Date 5/14/2022: Subject to change without notice © Copyright Siemens 2022
- Product Article Number (Market Facing Number): 6SL3246-0BA22-1PA0
- Product family: Control Units
- Product Lifecycle (PLM): PM300:Active Product
- Delivery information Export Control Regulations: AL : N / ECCN : 3A999A
- Standard lead time ex-works: 150 Day/Days
- Net Weight (kg): 0,610 Kg
- Packaging Dimension: 93,00 x 240,00 x 68,00
- Package size unit of measure: MM
- Quantity Unit: 1 Piece
- Packaging Quantity: 1
- Additional Product Information EAN: 4042948664124
- UPC: 887621263539
- Commodity Code: 85049090
- LKZ_FDB/ CatalogID: D11.1SD
- Product Group: 9779
More info
▲Technical data
| SINAMICS G120 CONTROL UNIT CU250S-2 DP INTEGRIERT PROFIBUS SUPPORT OF VECTOR CONTROL, EASY POSITIONING EPOS VIA EXTENDED FUNCTION LICENSE 4 CONFIGURABLE DI/DO, 6 DI (3 F-DI), 5 DI, 3 DO (1 F-DO), 2 AI, 2 AO SAFETY INTEGRATED STO, SBC, SS1 FURTHER SAFETY FUNCTIONS VIA EXTENDED SAFETY LICENSE ENCODER: D-CLIQ + HTL/TTL/SSI, RESOLVER/HTL VIA TERMINAL PROTECTION IP20 USB- AND SD/MMC-INTERFACE | |||
Downloads and manuals | |||
| Further information | |||
Industry Online Support (Manuals, Catalogs, Certificates, FAQ, ...) | |||
Industry Mall (Online ordering system) | |||
| Date 5/14/2022 | Subject to change without notice © Copyright Siemens 2022 | ||
Additional data
| Product | ||||||||||||||||||||||||||||||||||||||||
| Article Number (Market Facing Number) | 6SL3246-0BA22-1PA0 | |||||||||||||||||||||||||||||||||||||||
| Product Description | SINAMICS G120 CONTROL UNIT CU250S-2 DP INTEGRIERT PROFIBUS SUPPORT OF VECTOR CONTROL, EASY POSITIONING EPOS VIA EXTENDED FUNCTION LICENSE 4 CONFIGURABLE DI/DO, 6 DI (3 F-DI), 5 DI, 3 DO (1 F-DO), 2 AI, 2 AO SAFETY INTEGRATED STO, SBC, SS1 FURTHER SAFETY FUNCTIONS VIA EXTENDED SAFETY LICENSE ENCODER: D-CLIQ + HTL/TTL/SSI, RESOLVER/HTL VIA TERMINAL PROTECTION IP20 USB- AND SD/MMC-INTERFACE | |||||||||||||||||||||||||||||||||||||||
| Product family | Control Units | |||||||||||||||||||||||||||||||||||||||
| Product Lifecycle (PLM) | PM300:Active Product | |||||||||||||||||||||||||||||||||||||||
| Price data | ||||||||||||||||||||||||||||||||||||||||
| Region Specific PriceGroup / Headquarter Price Group | 342 / 342 | |||||||||||||||||||||||||||||||||||||||
| Surcharge for Raw Materials | None | |||||||||||||||||||||||||||||||||||||||
| Metal Factor | None | |||||||||||||||||||||||||||||||||||||||
| Delivery information | ||||||||||||||||||||||||||||||||||||||||
| Export Control Regulations | AL : N / ECCN : 3A999A | |||||||||||||||||||||||||||||||||||||||
| Standard lead time ex-works | 150 Day/Days | |||||||||||||||||||||||||||||||||||||||
| Net Weight (kg) | 0,610 Kg | |||||||||||||||||||||||||||||||||||||||
| Packaging Dimension | 93,00 x 240,00 x 68,00 | |||||||||||||||||||||||||||||||||||||||
| Package size unit of measure | MM | |||||||||||||||||||||||||||||||||||||||
| Quantity Unit | 1 Piece | |||||||||||||||||||||||||||||||||||||||
| Packaging Quantity | 1 | |||||||||||||||||||||||||||||||||||||||
| Additional Product Information | ||||||||||||||||||||||||||||||||||||||||
| EAN | 4042948664124 | |||||||||||||||||||||||||||||||||||||||
| UPC | 887621263539 | |||||||||||||||||||||||||||||||||||||||
| Commodity Code | 85049090 | |||||||||||||||||||||||||||||||||||||||
| LKZ_FDB/ CatalogID | D11.1SD | |||||||||||||||||||||||||||||||||||||||
| Product Group | 9779 | |||||||||||||||||||||||||||||||||||||||
| Group Code | R220 | |||||||||||||||||||||||||||||||||||||||
| Country of origin | Great Britain | |||||||||||||||||||||||||||||||||||||||
| Compliance with the substance restrictions according to RoHS directive | Since: 01.07.2006 | |||||||||||||||||||||||||||||||||||||||
| Product class | A: Standard product which is a stock item could be returned within the returns guidelines/period. | |||||||||||||||||||||||||||||||||||||||
| WEEE (2012/19/EU) Take-Back Obligation | Yes | |||||||||||||||||||||||||||||||||||||||
| REACH Art. 33 Duty to inform according to the current list of candidates |
| |||||||||||||||||||||||||||||||||||||||
| Classifications | ||||||||||||||||||||||||||||||||||||||||
| ||||||||||||||||||||||||||||||||||||||||
ETIM data
ETIM: EC001857 - Frequency converter =< 1 kV
| Value | Unit | |
|---|---|---|
| Number of interfaces PROFINET (EF006932) | - | |
| Application in domestic- and commercial area permitted (EF007295) | - | |
| Relative symmetric net frequency tolerance (EF007454) | - | % |
| Depth (EF000049) | - | mm |
| Number of HW-interfaces industrial Ethernet (EF003020) | - | |
| Supporting protocol for INTERBUS (EF003054) | - | |
| Supporting protocol for AS-Interface Safety at Work (EF007519) | - | |
| Supporting protocol for PROFIsafe (EF007526) | - | |
| Number of analogue inputs (EF001994) | - | |
| With optical interface (EF003028) | - | |
| Degree of protection (IP) (EF005474) | - | |
| With PC connection (EF006107) | - | |
| Supporting protocol for INTERBUS-Safety (EF006662) | - | |
| Mains voltage (EF006780) | - | V |
| Type of converter (EF006978) | - | |
| Supporting protocol for Foundation Fieldbus (EF007522) | - | |
| Mains frequency (EF006783) | - | |
| Nominal output current I2N (EF009561) | - | A |
| Number of digital outputs (EF001993) | - | |
| Number of HW-interfaces USB (EF003025) | - | |
| Supporting protocol for ASI (EF003051) | - | |
| Supporting protocol for other bus systems (EF003062) | - | |
| Supporting protocol for SERCOS (EF006657) | - | |
| Number of phases output (EF006998) | - | |
| Max. output voltage (EF009560) | - | V |
| Supporting protocol for EtherNet/IP (EF007521) | - | |
| Number of analogue outputs (EF001995) | - | |
| Number of HW-interfaces serial TTY (EF003024) | - | |
| Application in industrial area permitted (EF007294) | - | |
| Relative symmetric net voltage tolerance (EF007453) | - | % |
| Supporting protocol for DeviceNet Safety (EF007520) | - | |
| Supporting protocol for PROFINET IO (EF007525) | - | |
| With control unit (EF001538) | - | |
| Supporting protocol for KNX (EF003055) | - | |
| Supporting protocol for SUCONET (EF003060) | - | |
| 4-quadrant operation possible (EF006803) | - | |
| Max. output at quadratic load at rated output voltage (EF007366) | - | kW |
| Supporting protocol for PROFINET CBA (EF007524) | - | |
| Supporting protocol for DeviceNet (EF003059) | - | |
| Width (EF000008) | - | mm |
| Height (EF000040) | - | mm |
| Number of digital inputs (EF001992) | - | |
| Number of HW-interfaces RS-422 (EF003022) | - | |
| Number of HW-interfaces RS-485 (EF003023) | - | |
| Number of HW-interfaces parallel (EF003026) | - | |
| Number of HW-interfaces other (EF003027) | - | |
| Integrated breaking resistance (EF007293) | - | |
| Max. output at linear load at rated output voltage (EF007364) | - | kW |
| Supporting protocol for SafetyBUS p (EF007527) | - | |
| Number of HW-interfaces RS-232 (EF003021) | - | |
| Supporting protocol for TCP/IP (EF003050) | - | |
| Supporting protocol for LON (EF003017) | - | |
| Supporting protocol for PROFIBUS (EF003052) | - | |
| Supporting protocol for CAN (EF003053) | - | |
| Supporting protocol for Modbus (EF003057) | - | |
| Supporting protocol for Data-Highway (EF003058) | - | |
| Max. output frequency (EF007350) | - | Hz |
| Supporting protocol for BACnet (EF011944) | - | |
| Degree of protection (NEMA) (EF011959) | - | |
| Number of phases input (EF007117) | - |