View larger
6SL3211-1PE32-5UL0 SIEMENS SINAMICS G120 POWER MODULE PM240-2 Push Through, WITHOUT FILTER WITH BUILT IN BRA..
6SL3211-1PE32-5UL0
10000
SIEMENS
1 Pcs.
Automation > Frequency converter less than 1 kV
SINAMICS G120 Power Modules Size A
Product condition, packaging, certifications and applicable manufacturer warranty terms are confirmed with the quotation.
Request a Quote
Pricing and availability are confirmed for each enquiry. Send this part and we will reply with price and lead time.
Request QuoteProduct Overview
Siemens SINAMICS G120 POWER MODULE PM240-2 is a power module component designed to supply and protect drive systems within industrial automation configurations. Power modules process incoming electrical energy to drive connected motors efficiently while supporting safety and braking functions.
Pricing, availability and lead time are confirmed per enquiry through an RFQ.
- Date 5/14/2022: Subject to change without notice © Copyright Siemens 2022
- Product Article Number (Market Facing Number): 6SL3211-1PE32-5UL0
- Product family: Power Modules
- Product Lifecycle (PLM): PM400:Phase Out Started
- PLM Effective Date: Product phase-out since: 01.10.2021
- Delivery information Export Control Regulations: AL : N / ECCN : EAR99H
- Standard lead time ex-works: 30 Day/Days
- Net Weight (kg): 63,500 Kg
- Packaging Dimension: 400,00 x 900,00 x 607,00
- Package size unit of measure: MM
- Quantity Unit: 1 Piece
- Packaging Quantity: 1
- Additional Product Information EAN: 4042948675878
- UPC: 804766497582
- Commodity Code: 85044088
- LKZ_FDB/ CatalogID: D11.1SD
More info
▲Technical data
| SINAMICS G120 POWER MODULE PM240-2 Push Through, WITHOUT FILTER WITH BUILT IN BRAKING CHOPPER 3AC380-480V +10/-20% 47-63HZ OUTPUT HIGH OVERLOAD: 110KW FOR 200% 3S,150% 57S,100% 240S AMBIENT TEMP -20 TO +50 DEG C (HO) OUTPUT LOW OVERLOAD: 132kW FOR 150% 3S,110% 57S,100% 240S AMBIENT TEMP -20 TO +40 DEG C (LO) 754x384x358 (HXWXD), FSF PROTECTION IP20 WITHOUT CONTROL UNIT AND PANEL APPROVED FOR CU FIRMWARE- VERSION V4.7 SP6 | |||
Downloads and manuals | |||
| Further information | |||
Industry Online Support (Manuals, Catalogs, Certificates, FAQ, ...) | |||
Industry Mall (Online ordering system) | |||
| Date 5/14/2022 | Subject to change without notice © Copyright Siemens 2022 | ||
Additional data
| Product | |||||||||||||||||||||||||||||||||||||
| Article Number (Market Facing Number) | 6SL3211-1PE32-5UL0 | ||||||||||||||||||||||||||||||||||||
| Product Description | SINAMICS G120 POWER MODULE PM240-2 Push Through, WITHOUT FILTER WITH BUILT IN BRAKING CHOPPER 3AC380-480V +10/-20% 47-63HZ OUTPUT HIGH OVERLOAD: 110KW FOR 200% 3S,150% 57S,100% 240S AMBIENT TEMP -20 TO +50 DEG C (HO) OUTPUT LOW OVERLOAD: 132kW FOR 150% 3S,110% 57S,100% 240S AMBIENT TEMP -20 TO +40 DEG C (LO) 754x384x358 (HXWXD), FSF PROTECTION IP20 WITHOUT CONTROL UNIT AND PANEL APPROVED FOR CU FIRMWARE- VERSION V4.7 SP6 | ||||||||||||||||||||||||||||||||||||
| Product family | Power Modules | ||||||||||||||||||||||||||||||||||||
| Product Lifecycle (PLM) | PM400:Phase Out Started | ||||||||||||||||||||||||||||||||||||
| PLM Effective Date | Product phase-out since: 01.10.2021 | ||||||||||||||||||||||||||||||||||||
| Price data | |||||||||||||||||||||||||||||||||||||
| Region Specific PriceGroup / Headquarter Price Group | 339 / 339 | ||||||||||||||||||||||||||||||||||||
| Surcharge for Raw Materials | None | ||||||||||||||||||||||||||||||||||||
| Metal Factor | None | ||||||||||||||||||||||||||||||||||||
| Delivery information | |||||||||||||||||||||||||||||||||||||
| Export Control Regulations | AL : N / ECCN : EAR99H | ||||||||||||||||||||||||||||||||||||
| Standard lead time ex-works | 30 Day/Days | ||||||||||||||||||||||||||||||||||||
| Net Weight (kg) | 63,500 Kg | ||||||||||||||||||||||||||||||||||||
| Packaging Dimension | 400,00 x 900,00 x 607,00 | ||||||||||||||||||||||||||||||||||||
| Package size unit of measure | MM | ||||||||||||||||||||||||||||||||||||
| Quantity Unit | 1 Piece | ||||||||||||||||||||||||||||||||||||
| Packaging Quantity | 1 | ||||||||||||||||||||||||||||||||||||
| Additional Product Information | |||||||||||||||||||||||||||||||||||||
| EAN | 4042948675878 | ||||||||||||||||||||||||||||||||||||
| UPC | 804766497582 | ||||||||||||||||||||||||||||||||||||
| Commodity Code | 85044088 | ||||||||||||||||||||||||||||||||||||
| LKZ_FDB/ CatalogID | D11.1SD | ||||||||||||||||||||||||||||||||||||
| Product Group | 9775 | ||||||||||||||||||||||||||||||||||||
| Group Code | R220 | ||||||||||||||||||||||||||||||||||||
| Country of origin | Germany | ||||||||||||||||||||||||||||||||||||
| Compliance with the substance restrictions according to RoHS directive | Since: 01.08.2017 | ||||||||||||||||||||||||||||||||||||
| Product class | C: products manufactured / produced to order, which cannot be reused or re-utilised or be returned against credit. | ||||||||||||||||||||||||||||||||||||
| WEEE (2012/19/EU) Take-Back Obligation | Yes | ||||||||||||||||||||||||||||||||||||
| REACH Art. 33 Duty to inform according to the current list of candidates |
| ||||||||||||||||||||||||||||||||||||
| Classifications | |||||||||||||||||||||||||||||||||||||
| |||||||||||||||||||||||||||||||||||||
ETIM data
ETIM: EC001857 - Frequency converter =< 1 kV
| Value | Unit | |
|---|---|---|
| Number of digital outputs (EF001993) | - | |
| Number of analogue outputs (EF001995) | - | |
| Max. output voltage (EF009560) | - | V |
| Number of analogue inputs (EF001994) | - | |
| Degree of protection (NEMA) (EF011959) | - | |
| Number of digital inputs (EF001992) | - | |
| Supporting protocol for BACnet (EF011944) | - | |
| Mains voltage (EF006780) | ['380', '480'] | V |
| Number of phases input (EF007117) | 3 | |
| Number of phases output (EF006998) | 3 | |
| Max. output frequency (EF007350) | 550 | Hz |
| Nominal output current I2N (EF009561) | 250 | A |
| Max. output at quadratic load at rated output voltage (EF007366) | 132.0 | kW |
| Max. output at linear load at rated output voltage (EF007364) | 110.0 | kW |
| Relative symmetric net frequency tolerance (EF007454) | 5 | % |
| Relative symmetric net voltage tolerance (EF007453) | -10 | % |
| With control unit (EF001538) | false | |
| Application in industrial area permitted (EF007294) | false | |
| Application in domestic- and commercial area permitted (EF007295) | false | |
| Supporting protocol for TCP/IP (EF003050) | - | |
| Supporting protocol for PROFIBUS (EF003052) | - | |
| Supporting protocol for CAN (EF003053) | - | |
| Supporting protocol for INTERBUS (EF003054) | - | |
| Supporting protocol for ASI (EF003051) | - | |
| Supporting protocol for KNX (EF003055) | - | |
| Supporting protocol for Modbus (EF003057) | - | |
| Supporting protocol for Data-Highway (EF003058) | - | |
| Supporting protocol for DeviceNet (EF003059) | - | |
| Supporting protocol for SUCONET (EF003060) | - | |
| Supporting protocol for LON (EF003017) | - | |
| Supporting protocol for PROFINET IO (EF007525) | - | |
| Supporting protocol for PROFINET CBA (EF007524) | - | |
| Supporting protocol for SERCOS (EF006657) | - | |
| Supporting protocol for Foundation Fieldbus (EF007522) | - | |
| Supporting protocol for EtherNet/IP (EF007521) | - | |
| Supporting protocol for AS-Interface Safety at Work (EF007519) | - | |
| Supporting protocol for DeviceNet Safety (EF007520) | - | |
| Supporting protocol for INTERBUS-Safety (EF006662) | - | |
| Supporting protocol for PROFIsafe (EF007526) | - | |
| Supporting protocol for SafetyBUS p (EF007527) | - | |
| Supporting protocol for other bus systems (EF003062) | - | |
| Number of HW-interfaces industrial Ethernet (EF003020) | - | |
| Number of interfaces PROFINET (EF006932) | - | |
| Number of HW-interfaces RS-232 (EF003021) | - | |
| Number of HW-interfaces RS-422 (EF003022) | - | |
| Number of HW-interfaces RS-485 (EF003023) | - | |
| Number of HW-interfaces serial TTY (EF003024) | - | |
| Number of HW-interfaces USB (EF003025) | - | |
| Number of HW-interfaces parallel (EF003026) | - | |
| Number of HW-interfaces other (EF003027) | - | |
| With optical interface (EF003028) | - | |
| With PC connection (EF006107) | - | |
| Integrated breaking resistance (EF007293) | true | |
| 4-quadrant operation possible (EF006803) | false | |
| Type of converter (EF006978) | U converter | |
| Degree of protection (IP) (EF005474) | IP20 | |
| Height (EF000040) | 754.0 | mm |
| Width (EF000008) | 384.0 | mm |
| Depth (EF000049) | 358.0 | mm |
| Mains frequency (EF006783) | - |