View larger
6SL3211-1NE23-8AG1 SIEMENS SINAMICS G120 Power Module PM230 with integrated Class A filter Degree of protect..
6SL3211-1NE23-8AG1
32111
SIEMENS
1 Pcs.
Automation > Frequency converter less than 1 kV
DRIVES
Product condition, packaging, certifications and applicable manufacturer warranty terms are confirmed with the quotation.
Request a Quote
Pricing and availability are confirmed for each enquiry. Send this part and we will reply with price and lead time.
Request QuoteProduct Overview
Siemens engineers designed the 6SL3211-1NE23-8AG1 Sinamics G120 Power Module PM230 to convert electrical power efficiently for industrial drive systems. Power modules form the core of modular inverter setups, supplying controlled voltage and frequency to heavy-duty motors in manufacturing plants.
Pricing, availability, and lead time are confirmed per enquiry through an RFQ.
- Mains voltage (EF006780): ['380', '480']
- Number of phases input (EF007117): 3
- Number of phases output (EF006998): 3
- Max. output frequency (EF007350): 550
- Nominal output current I2N (EF009561): 38
- Relative symmetric net frequency tolerance (EF007454): 5
- Relative symmetric net voltage tolerance (EF007453): -10
- With control unit (EF001538): false
- Application in industrial area permitted (EF007294): true
- Integrated breaking resistance (EF007293): false
- 4-quadrant operation possible (EF006803): false
- Type of converter (EF006978): U converter
- Degree of protection (IP) (EF005474): IP20
- Height (EF000040): 411.0
- Width (EF000008): 200.0
- Depth (EF000049): 171.0
More info
▲ETIM: EC001857 - Frequency converter =< 1 kV
| Value | Unit | |
|---|---|---|
| Number of analogue inputs (EF001994) | - | |
| Supporting protocol for BACnet (EF011944) | - | |
| Degree of protection (NEMA) (EF011959) | - | |
| Number of analogue outputs (EF001995) | - | |
| Max. output voltage (EF009560) | - | V |
| Number of digital outputs (EF001993) | - | |
| Number of digital inputs (EF001992) | - | |
| Mains voltage (EF006780) | ['380', '480'] | V |
| Number of phases input (EF007117) | 3 | |
| Number of phases output (EF006998) | 3 | |
| Max. output frequency (EF007350) | 550 | Hz |
| Nominal output current I2N (EF009561) | 38 | A |
| Max. output at quadratic load at rated output voltage (EF007366) | 18.5 | kW |
| Max. output at linear load at rated output voltage (EF007364) | 15.0 | kW |
| Relative symmetric net frequency tolerance (EF007454) | 5 | % |
| Relative symmetric net voltage tolerance (EF007453) | -10 | % |
| With control unit (EF001538) | false | |
| Application in industrial area permitted (EF007294) | true | |
| Application in domestic- and commercial area permitted (EF007295) | false | |
| Supporting protocol for TCP/IP (EF003050) | - | |
| Supporting protocol for PROFIBUS (EF003052) | - | |
| Supporting protocol for CAN (EF003053) | - | |
| Supporting protocol for INTERBUS (EF003054) | - | |
| Supporting protocol for ASI (EF003051) | - | |
| Supporting protocol for KNX (EF003055) | - | |
| Supporting protocol for Modbus (EF003057) | - | |
| Supporting protocol for Data-Highway (EF003058) | - | |
| Supporting protocol for DeviceNet (EF003059) | - | |
| Supporting protocol for SUCONET (EF003060) | - | |
| Supporting protocol for LON (EF003017) | - | |
| Supporting protocol for PROFINET IO (EF007525) | - | |
| Supporting protocol for PROFINET CBA (EF007524) | - | |
| Supporting protocol for SERCOS (EF006657) | - | |
| Supporting protocol for Foundation Fieldbus (EF007522) | - | |
| Supporting protocol for EtherNet/IP (EF007521) | - | |
| Supporting protocol for AS-Interface Safety at Work (EF007519) | - | |
| Supporting protocol for DeviceNet Safety (EF007520) | - | |
| Supporting protocol for INTERBUS-Safety (EF006662) | - | |
| Supporting protocol for PROFIsafe (EF007526) | - | |
| Supporting protocol for SafetyBUS p (EF007527) | - | |
| Supporting protocol for other bus systems (EF003062) | - | |
| Number of HW-interfaces industrial Ethernet (EF003020) | - | |
| Number of interfaces PROFINET (EF006932) | - | |
| Number of HW-interfaces RS-232 (EF003021) | - | |
| Number of HW-interfaces RS-422 (EF003022) | - | |
| Number of HW-interfaces RS-485 (EF003023) | - | |
| Number of HW-interfaces serial TTY (EF003024) | - | |
| Number of HW-interfaces USB (EF003025) | - | |
| Number of HW-interfaces parallel (EF003026) | - | |
| Number of HW-interfaces other (EF003027) | - | |
| With optical interface (EF003028) | - | |
| With PC connection (EF006107) | - | |
| Integrated breaking resistance (EF007293) | false | |
| 4-quadrant operation possible (EF006803) | false | |
| Type of converter (EF006978) | U converter | |
| Degree of protection (IP) (EF005474) | IP20 | |
| Height (EF000040) | 411.0 | mm |
| Width (EF000008) | 200.0 | mm |
| Depth (EF000049) | 171.0 | mm |
| Mains frequency (EF006783) | - |
| SINAMICS G120 Power Module PM230 with integrated Class A filter Degree of protection IP20/PT 380-480 V 3 AC +10/-10% 47-63 Hz Power low overload: 18.5kW at 150% 3s, 110% 57s, 100% 240 s; Ambient temperature 0 to +40 °C (LO) 411x 200x 171 (HxWxD), FSC without Control Unit and operating unit released for CU240B/E-2 and CU230P-2 Firmware version V4.4 or higher | |||
| Further information | |||
Industry Online Support (Manuals, Catalogs, Certificates, FAQ, ...) | |||
Industry Mall (Online ordering system) | |||
| Product | ||||||||||||||||||||||||||||||||||
| Article Number (Market Facing Number) | 6SL3211-1NE23-8AG1 | |||||||||||||||||||||||||||||||||
| Product Description | SINAMICS G120 Power Module PM230 with integrated Class A filter Degree of protection IP20/PT 380-480 V 3 AC +10/-10% 47-63 Hz Power low overload: 18.5kW at 150% 3s, 110% 57s, 100% 240 s; Ambient temperature 0 to +40 °C (LO) 411x 200x 171 (HxWxD), FSC without Control Unit and operating unit released for CU240B/E-2 and CU230P-2 Firmware version V4.4 or higher | |||||||||||||||||||||||||||||||||
| Product family | PM230 Power Modules | |||||||||||||||||||||||||||||||||
| Product Lifecycle (PLM) | PM300:Active Product | |||||||||||||||||||||||||||||||||
| PLM Effective Date | Product phase-out since: 12.12.2022 | |||||||||||||||||||||||||||||||||
| Price data | ||||||||||||||||||||||||||||||||||
| Price Group | 347 | |||||||||||||||||||||||||||||||||
| Surcharge for Raw Materials | None | |||||||||||||||||||||||||||||||||
| Metal Factor | None | |||||||||||||||||||||||||||||||||
| Delivery information | ||||||||||||||||||||||||||||||||||
| Export Control Regulations | AL : 9I999IR / ECCN : 3A999A | |||||||||||||||||||||||||||||||||
| Standard lead time ex-works | 3 Day/Days | |||||||||||||||||||||||||||||||||
| Net Weight (kg) | 5,500 Kg | |||||||||||||||||||||||||||||||||
| Product Dimensions (W x L x H) | Not available | |||||||||||||||||||||||||||||||||
| Packaging Dimension | 205,00 x 245,00 x 442,00 | |||||||||||||||||||||||||||||||||
| Package size unit of measure | MM | |||||||||||||||||||||||||||||||||
| Quantity Unit | 1 Piece | |||||||||||||||||||||||||||||||||
| Packaging Quantity | 1 | |||||||||||||||||||||||||||||||||
| Additional Product Information | ||||||||||||||||||||||||||||||||||
| EAN | 4042948671436 | |||||||||||||||||||||||||||||||||
| UPC | 804766790850 | |||||||||||||||||||||||||||||||||
| Commodity Code | 85044088 | |||||||||||||||||||||||||||||||||
| LKZ_FDB/ CatalogID | D11.1SD | |||||||||||||||||||||||||||||||||
| Product Group | 9777 | |||||||||||||||||||||||||||||||||
| Group Code | R220 | |||||||||||||||||||||||||||||||||
| Country of origin | Great Britain | |||||||||||||||||||||||||||||||||
| Compliance with the substance restrictions according to RoHS directive | Since: 01.07.2006 | |||||||||||||||||||||||||||||||||
| Product class | A: Standard product which is a stock item could be returned within the returns guidelines/period. | |||||||||||||||||||||||||||||||||
| WEEE (2012/19/EU) Take-Back Obligation | Yes | |||||||||||||||||||||||||||||||||
| REACH Art. 33 Duty to inform according to the current list of candidates |
| |||||||||||||||||||||||||||||||||
| Classifications | ||||||||||||||||||||||||||||||||||
| ||||||||||||||||||||||||||||||||||