View larger
6SL3210-1RE24-5AL0 SIEMENS SINAMICS G120 POWER MODULE PM240P-2 WITH BUILT IN CL. A FILTER 3AC380-480V +10/-2..
6SL3210-1RE24-5AL0
32101
SIEMENS
1 Pcs.
Automation > Frequency converter less than 1 kV
DRIVES
Product condition, packaging, certifications and applicable manufacturer warranty terms are confirmed with the quotation.
Request a Quote
Pricing and availability are confirmed for each enquiry. Send this part and we will reply with price and lead time.
Request QuoteProduct Overview
The 6SL3210-1RE24-5AL0 Siemens Sinamics G120 Power Module PM240P-2 is a three-phase power converter designed to regulate motor speeds and optimize energy efficiency in heavy-duty automated systems. Units of this type are deployed across manufacturing plants to manage conveyor belts, pumps, and fans by translating fixed mains electricity into variable frequency output.
Pricing, availability and lead time are confirmed per enquiry through an RFQ.
- Mains voltage (EF006780): ['380', '480']
- Number of phases input (EF007117): 3
- Number of phases output (EF006998): 3
- Max. output frequency (EF007350): 550
- Nominal output current I2N (EF009561): 45
- Relative symmetric net frequency tolerance (EF007454): 5
- Relative symmetric net voltage tolerance (EF007453): -10
- With control unit (EF001538): false
- Application in industrial area permitted (EF007294): true
- Integrated breaking resistance (EF007293): false
- 4-quadrant operation possible (EF006803): false
- Type of converter (EF006978): U converter
- Degree of protection (IP) (EF005474): IP20
- Height (EF000040): 472.0
- Width (EF000008): 200.0
- Depth (EF000049): 237.0
More info
▲ETIM: EC001857 - Frequency converter =< 1 kV
| Value | Unit | |
|---|---|---|
| Supporting protocol for BACnet (EF011944) | - | |
| Number of analogue outputs (EF001995) | - | |
| Degree of protection (NEMA) (EF011959) | - | |
| Number of digital inputs (EF001992) | - | |
| Number of analogue inputs (EF001994) | - | |
| Number of digital outputs (EF001993) | - | |
| Max. output voltage (EF009560) | - | V |
| Mains voltage (EF006780) | ['380', '480'] | V |
| Number of phases input (EF007117) | 3 | |
| Number of phases output (EF006998) | 3 | |
| Max. output frequency (EF007350) | 550 | Hz |
| Nominal output current I2N (EF009561) | 45 | A |
| Max. output at quadratic load at rated output voltage (EF007366) | 22.0 | kW |
| Max. output at linear load at rated output voltage (EF007364) | 18.5 | kW |
| Relative symmetric net frequency tolerance (EF007454) | 5 | % |
| Relative symmetric net voltage tolerance (EF007453) | -10 | % |
| With control unit (EF001538) | false | |
| Application in industrial area permitted (EF007294) | true | |
| Application in domestic- and commercial area permitted (EF007295) | false | |
| Supporting protocol for TCP/IP (EF003050) | - | |
| Supporting protocol for PROFIBUS (EF003052) | - | |
| Supporting protocol for CAN (EF003053) | - | |
| Supporting protocol for INTERBUS (EF003054) | - | |
| Supporting protocol for ASI (EF003051) | - | |
| Supporting protocol for KNX (EF003055) | - | |
| Supporting protocol for Modbus (EF003057) | - | |
| Supporting protocol for Data-Highway (EF003058) | - | |
| Supporting protocol for DeviceNet (EF003059) | - | |
| Supporting protocol for SUCONET (EF003060) | - | |
| Supporting protocol for LON (EF003017) | - | |
| Supporting protocol for PROFINET IO (EF007525) | - | |
| Supporting protocol for PROFINET CBA (EF007524) | - | |
| Supporting protocol for SERCOS (EF006657) | - | |
| Supporting protocol for Foundation Fieldbus (EF007522) | - | |
| Supporting protocol for EtherNet/IP (EF007521) | - | |
| Supporting protocol for AS-Interface Safety at Work (EF007519) | - | |
| Supporting protocol for DeviceNet Safety (EF007520) | - | |
| Supporting protocol for INTERBUS-Safety (EF006662) | - | |
| Supporting protocol for PROFIsafe (EF007526) | - | |
| Supporting protocol for SafetyBUS p (EF007527) | - | |
| Supporting protocol for other bus systems (EF003062) | - | |
| Number of HW-interfaces industrial Ethernet (EF003020) | - | |
| Number of interfaces PROFINET (EF006932) | - | |
| Number of HW-interfaces RS-232 (EF003021) | - | |
| Number of HW-interfaces RS-422 (EF003022) | - | |
| Number of HW-interfaces RS-485 (EF003023) | - | |
| Number of HW-interfaces serial TTY (EF003024) | - | |
| Number of HW-interfaces USB (EF003025) | - | |
| Number of HW-interfaces parallel (EF003026) | - | |
| Number of HW-interfaces other (EF003027) | - | |
| With optical interface (EF003028) | - | |
| With PC connection (EF006107) | - | |
| Integrated breaking resistance (EF007293) | false | |
| 4-quadrant operation possible (EF006803) | false | |
| Type of converter (EF006978) | U converter | |
| Degree of protection (IP) (EF005474) | IP20 | |
| Height (EF000040) | 472.0 | mm |
| Width (EF000008) | 200.0 | mm |
| Depth (EF000049) | 237.0 | mm |
| Mains frequency (EF006783) | - |
| SINAMICS G120 POWER MODULE PM240P-2 WITH BUILT IN CL. A FILTER 3AC380-480V +10/-20% 47-63HZ OUTPUT HIGH OVERLOAD: 18.5KW FOR 150% 60S, 100% 240S; AMBIENT TEMP -20 TO +50 DEG C (HO) OUTPUT LOW OVERLOAD: 22kW FOR 135% 3S, 110% 57S, 100% 240S AMBIENT TEMP -20 TO +40 DEG C (LO) 472 X 200 X 237 (HXWXD), FSD PROTECTION IP20 WITHOUT CONTROL UNIT AND PANEL APPROVED FOR CU FIRMWARE- VERSION V4.7 SP6 HF1 | |||
| Further information | |||
Industry Online Support (Manuals, Catalogs, Certificates, FAQ, ...) | |||
Industry Mall (Online ordering system) | |||
| Product | ||||||||||||||||||||||||||||||||||
| Article Number (Market Facing Number) | 6SL3210-1RE24-5AL0 | |||||||||||||||||||||||||||||||||
| Product Description | SINAMICS G120 POWER MODULE PM240P-2 WITH BUILT IN CL. A FILTER 3AC380-480V +10/-20% 47-63HZ OUTPUT HIGH OVERLOAD: 18.5KW FOR 150% 60S, 100% 240S; AMBIENT TEMP -20 TO +50 DEG C (HO) OUTPUT LOW OVERLOAD: 22kW FOR 135% 3S, 110% 57S, 100% 240S AMBIENT TEMP -20 TO +40 DEG C (LO) 472 X 200 X 237 (HXWXD), FSD PROTECTION IP20 WITHOUT CONTROL UNIT AND PANEL APPROVED FOR CU FIRMWARE- VERSION V4.7 SP6 HF1 | |||||||||||||||||||||||||||||||||
| Product family | PM240P-2 Power Modules | |||||||||||||||||||||||||||||||||
| Product Lifecycle (PLM) | PM300:Active Product | |||||||||||||||||||||||||||||||||
| Price data | ||||||||||||||||||||||||||||||||||
| Price Group | 347 | |||||||||||||||||||||||||||||||||
| Surcharge for Raw Materials | None | |||||||||||||||||||||||||||||||||
| Metal Factor | None | |||||||||||||||||||||||||||||||||
| Delivery information | ||||||||||||||||||||||||||||||||||
| Export Control Regulations | AL : N / ECCN : EAR99H | |||||||||||||||||||||||||||||||||
| Standard lead time ex-works | 10 Day/Days | |||||||||||||||||||||||||||||||||
| Net Weight (kg) | 18,300 Kg | |||||||||||||||||||||||||||||||||
| Product Dimensions (W x L x H) | Not available | |||||||||||||||||||||||||||||||||
| Packaging Dimension | 356,00 x 495,00 x 300,00 | |||||||||||||||||||||||||||||||||
| Package size unit of measure | MM | |||||||||||||||||||||||||||||||||
| Quantity Unit | 1 Piece | |||||||||||||||||||||||||||||||||
| Packaging Quantity | 1 | |||||||||||||||||||||||||||||||||
| Additional Product Information | ||||||||||||||||||||||||||||||||||
| EAN | 4042948673362 | |||||||||||||||||||||||||||||||||
| UPC | 804766458682 | |||||||||||||||||||||||||||||||||
| Commodity Code | 85044088 | |||||||||||||||||||||||||||||||||
| LKZ_FDB/ CatalogID | D11.1SD | |||||||||||||||||||||||||||||||||
| Product Group | 5678 | |||||||||||||||||||||||||||||||||
| Group Code | R220 | |||||||||||||||||||||||||||||||||
| Country of origin | Germany | |||||||||||||||||||||||||||||||||
| Compliance with the substance restrictions according to RoHS directive | Since: 22.12.2016 | |||||||||||||||||||||||||||||||||
| Product class | C: products manufactured / produced to order, which cannot be reused or re-utilised or be returned against credit. | |||||||||||||||||||||||||||||||||
| WEEE (2012/19/EU) Take-Back Obligation | Yes | |||||||||||||||||||||||||||||||||
| REACH Art. 33 Duty to inform according to the current list of candidates |
| |||||||||||||||||||||||||||||||||
| Classifications | ||||||||||||||||||||||||||||||||||
| ||||||||||||||||||||||||||||||||||