6ES7151-8FB01-0AB0
10000
SIEMENS
1 Pcs.
Product condition, packaging, certifications and applicable manufacturer warranty terms are confirmed with the quotation.
| Value | Unit | |
|---|---|---|
| With integrated power supply (EF003338) | false | |
| Input voltage at AC 50 Hz (EF007118) | ['-', '-'] | V |
| Input voltage at AC 60 Hz (EF007119) | ['-', '-'] | V |
| Input voltage at DC (EF007120) | ['20.4', '28.8'] | V |
| Type of voltage (input voltage) (EF003033) | DC | |
| Max. input current AC 50 Hz (EF007360) | - | A |
| Max. input current AC 60 Hz (EF007361) | - | A |
| Max. input current DC (EF007362) | 0.352 | A |
| Output voltage at AC 50 Hz (EF006999) | ['-', '-'] | V |
| Output voltage at AC 60 Hz (EF007000) | ['-', '-'] | V |
| Output voltage at DC (EF007001) | ['-', '-'] | V |
| Type of output voltage (EF008222) | - | |
| Max. output current AC 50 Hz (EF007351) | - | A |
| Max. output current AC 60 Hz (EF007352) | - | A |
| Max. output current DC (EF007353) | - | A |
| Number of HW-interfaces industrial Ethernet (EF003020) | 1 | |
| Number of interfaces PROFINET (EF006932) | 3 | |
| Number of HW-interfaces RS-232 (EF003021) | 0 | |
| Number of HW-interfaces RS-422 (EF003022) | 0 | |
| Number of HW-interfaces RS-485 (EF003023) | 0 | |
| Number of HW-interfaces serial TTY (EF003024) | 0 | |
| Number of HW-interfaces USB (EF003025) | 0 | |
| Number of HW-interfaces parallel (EF003026) | 0 | |
| Number of HW-interfaces Wireless (EF006933) | 0 | |
| Number of HW-interfaces other (EF003027) | 0 | |
| With optical interface (EF003028) | false | |
| Supporting protocol for TCP/IP (EF003050) | true | |
| Supporting protocol for PROFIBUS (EF003052) | false | |
| Supporting protocol for CAN (EF003053) | false | |
| Supporting protocol for INTERBUS (EF003054) | false | |
| Supporting protocol for ASI (EF003051) | false | |
| Supporting protocol for KNX (EF003055) | false | |
| Supporting protocol for Modbus (EF003057) | true | |
| Supporting protocol for Data-Highway (EF003058) | false | |
| Supporting protocol for DeviceNet (EF003059) | false | |
| Supporting protocol for SUCONET (EF003060) | false | |
| Supporting protocol for LON (EF003017) | false | |
| Supporting protocol for SERCOS (EF006657) | false | |
| Supporting protocol for PROFINET IO (EF007525) | true | |
| Supporting protocol for PROFINET CBA (EF007524) | true | |
| Supporting protocol for Foundation Fieldbus (EF007522) | false | |
| Supporting protocol for EtherNet/IP (EF007521) | false | |
| Supporting protocol for AS-Interface Safety at Work (EF007519) | false | |
| Supporting protocol for DeviceNet Safety (EF007520) | false | |
| Supporting protocol for INTERBUS-Safety (EF006662) | false | |
| Supporting protocol for PROFIsafe (EF007526) | true | |
| Supporting protocol for SafetyBUS p (EF007527) | false | |
| Supporting protocol for other bus systems (EF003062) | true | |
| Radio standard Bluetooth (EF007178) | false | |
| Radio standard WLAN 802.11 (EF007179) | false | |
| Radio standard GPRS (EF008523) | false | |
| Radio standard GSM (EF008524) | false | |
| Radio standard UMTS (EF008525) | false | |
| IO link master (EF007298) | false | |
| System accessory (EF004118) | true | |
| Degree of protection (IP) (EF005474) | IP20 | |
| Number of slots (EF003077) | 63 | |
| With pluggable modules, digital I/O (EF003078) | true | |
| With pluggable modules, analogue I/O (EF003079) | true | |
| With pluggable modules, communication modules (EF003080) | true | |
| With pluggable modules, function and technology modules (EF003081) | true | |
| With pluggable modules, central modules (EF003082) | true | |
| With pluggable modules, others (EF003083) | true | |
| Type of electric connection (EF003961) | Screw-/spring clamp connection | |
| With potential separation (EF003272) | true | |
| Fieldbus connection over separate bus coupler possible (EF004002) | true | |
| With bus coupler for modular station connection (EF003990) | true | |
| Rail mounting possible (EF003972) | true | |
| Wall mounting/direct mounting (EF007020) | true | |
| Front build in possible (EF007016) | - | |
| Rack-assembly possible (EF007018) | - | |
| Suitable for safety functions (EF001597) | true | |
| Category according to EN 954-1 (EF006782) | 4 | |
| SIL according to IEC 61508 (EF009889) | 3 | |
| Performance level according to EN ISO 13849-1 (EF007399) | Level e | |
| Appendant operation agent (Ex ia) (EF004141) | false | |
| Appendant operation agent (Ex ib) (EF004142) | false | |
| Explosion safety category for gas (EF003997) | ATEX gas-ex-protection, Cat. 3G | |
| Explosion safety category for dust (EF003998) | None | |
| Width (EF000008) | 120.0 | mm |
| Height (EF000040) | 119.5 | mm |
| Depth (EF000049) | 75.0 | mm |
| SIMATIC DP, IM151-8F PN/DP CPU f. ET200S, 256 KB work memory, int. PROFINET interface (with three RJ45 ports) as IO controller/I-device without battery, MMC required | ||
| General information | ||
| HW functional status | 01 | |
| Firmware version | V3.2 | |
| Product function | ||
| ● Isochronous mode | No | |
| Engineering with | ||
| ● Programming package | STEP 7 V5.5 or higher, Distributed Safety V5.4 SP4 | |
| Supply voltage | ||
| Rated value (DC) | 24 V | |
| permissible range, lower limit (DC) | 20.4 V | |
| permissible range, upper limit (DC) | 28.8 V | |
| Reverse polarity protection | Yes; against destruction | |
| external protection for power supply lines (recommendation) | 2 A min. | |
| Mains buffering | ||
| ● Mains/voltage failure stored energy time | 5 ms | |
| Input current | ||
| Inrush current, max. | 1.8 A; Typical | |
| I²t | 0.13 A²·s | |
| from supply voltage 1L+, max. | 352 mA; 426 mA with DP master module | |
| Output current | ||
| for backplane bus (5 V DC), max. | 700 mA | |
| Power loss | ||
| Power loss, typ. | 5.5 W | |
| Memory | ||
| Work memory | ||
| ● integrated | 256 kbyte; For program and data | |
| ● expandable | No | |
| ● Size of retentive memory for retentive data blocks | 64 kbyte | |
| Load memory | ||
| ● Plug-in (MMC) | Yes | |
| ● Plug-in (MMC), max. | 8 Mbyte | |
| ● Data management on MMC (after last programming), min. | 10 y | |
| Backup | ||
| ● present | Yes; Ensured by SIMATIC Micro Memory Card (maintenance-free) | |
| CPU processing times | ||
| for bit operations, typ. | 0.06 µs | |
| for word operations, typ. | 0.12 µs | |
| for fixed point arithmetic, typ. | 0.16 µs | |
| for floating point arithmetic, typ. | 0.59 µs | |
| CPU-blocks | ||
| Number of blocks (total) | 1 024; (DBs, FCs, FBs); the maximum number of loadable blocks can be reduced by the MMC used. | |
| DB | ||
| ● Number, max. | 1 024; Number range: 1 to 16000 | |
| ● Size, max. | 64 kbyte | |
| FB | ||
| ● Number, max. | 1 024; Number range: 0 to 7999 | |
| ● Size, max. | 64 kbyte | |
| FC | ||
| ● Number, max. | 1 024; Number range: 0 to 7999 | |
| ● Size, max. | 64 kbyte | |
| OB | ||
| ● Description | See S7-300 operation list | |
| ● Size, max. | 64 kbyte | |
| ● Number of free cycle OBs | 1; OB 1 | |
| ● Number of time alarm OBs | 1; OB 10 | |
| ● Number of delay alarm OBs | 2; OB 20, 21 | |
| ● Number of cyclic interrupt OBs | 4; OB 32, 33, 34, 35 | |
| ● Number of process alarm OBs | 1; OB 40 | |
| ● Number of DPV1 alarm OBs | 3; OB 55, 56, 57 | |
| ● Number of isochronous mode OBs | 1; OB 61; only for PROFINET | |
| ● Number of startup OBs | 1; OB 100 | |
| ● Number of asynchronous error OBs | 6; OB 80, 82, 83, 85, 86, 87 (OB83 only for centralized I/O and PROFINET IO) | |
| ● Number of synchronous error OBs | 2; OB 121, 122 | |
| Nesting depth | ||
| ● per priority class | 16 | |
| ● additional within an error OB | 4 | |
| Counters, timers and their retentivity | ||
| S7 counter | ||
| ● Number | 256 | |
| Retentivity | ||
| — adjustable | Yes | |
| — lower limit | 0 | |
| — upper limit | 255 | |
| — preset | Z 0 to Z 7 | |
| Counting range | ||
| — adjustable | Yes | |
| — lower limit | 0 | |
| — upper limit | 999 | |
| IEC counter | ||
| ● present | Yes | |
| ● Type | SFB | |
| ● Number | Unlimited (limited only by RAM capacity) | |
| S7 times | ||
| ● Number | 256 | |
| Retentivity | ||
| — adjustable | Yes | |
| — lower limit | 0 | |
| — upper limit | 255 | |
| — preset | No retentivity | |
| Time range | ||
| — lower limit | 10 ms | |
| — upper limit | 9 990 s | |
| IEC timer | ||
| ● present | Yes | |
| ● Type | SFB | |
| ● Number | Unlimited (limited only by RAM capacity) | |
| Data areas and their retentivity | ||
| Flag | ||
| ● Number, max. | 256 byte | |
| ● Retentivity available | Yes | |
| ● Retentivity preset | MB 0 to MB 15 | |
| ● Number of clock memories | 8; 1 memory byte | |
| Data blocks | ||
| ● Retentivity adjustable | Yes; via non-retain property on DB | |
| ● Retentivity preset | Yes | |
| Local data | ||
| ● per priority class, max. | 32 768 byte; Max. 2048 bytes per block | |
| Address area | ||
| I/O address area | ||
| ● Inputs | 2 048 byte | |
| ● Outputs | 2 048 byte | |
| of which distributed | ||
| — Inputs | 2 048 byte | |
| — Outputs | 2 048 byte | |
| Process image | ||
| ● Inputs, adjustable | 2 048 byte | |
| ● Outputs, adjustable | 2 048 byte | |
| ● Inputs, default | 128 byte | |
| ● Outputs, default | 128 byte | |
| Subprocess images | ||
| ● Number of subprocess images, max. | 1; With PROFINET IO, the length of the user data is limited to 1600 bytes | |
| Digital channels | ||
| ● Inputs | 16 336 | |
| — of which central | 496 | |
| ● Outputs | 16 336 | |
| — of which central | 496 | |
| Analog channels | ||
| ● Inputs | 1 021 | |
| — of which central | 124 | |
| ● Outputs | 1 021 | |
| — of which central | 124 | |
| Hardware configuration | ||
| Number of modules per system, max. | 63; Centralized | |
| Mounting rail | ||
| ● Number of mounting rails that can be used | 1 | |
| ● Length of mounting rail, max. | Station width: ≤ 1 m or < 2 m | |
| Time of day | ||
| Clock | ||
| ● Hardware clock (real-time) | Yes | |
| ● retentive and synchronizable | Yes | |
| ● Backup time | 6 wk; At 40 °C ambient temperature, typically | |
| ● Deviation per day, max. | 10 s; Typ.: 2 s | |
| ● Behavior of the clock following POWER-ON | Clock continues running after POWER OFF | |
| ● Behavior of the clock following expiry of backup period | Clock continues to run with the time at which the power failure occurred | |
| Operating hours counter | ||
| ● Number | 1 | |
| ● Number/Number range | 0 | |
| ● Range of values | 0 to 2^31 hours (when using SFC 101) | |
| ● Granularity | 1 h | |
| ● retentive | Yes; Must be restarted at each restart | |
| Clock synchronization | ||
| ● supported | Yes | |
| ● to MPI, master | No | |
| ● to MPI, slave | No | |
| ● to DP, master | Yes; With DP master module | |
| ● to DP, slave | Yes; With DP master module | |
| ● in AS, master | No | |
| ● in AS, slave | No | |
| ● on Ethernet via NTP | Yes; As client | |
| 1. Interface | ||
| Interface type | PROFINET | |
| Physics | Ethernet | |
| Isolated | Yes | |
| automatic detection of transmission rate | Yes | |
| Autonegotiation | Yes | |
| Autocrossing | Yes | |
| Change of IP address at runtime, supported | Yes | |
| Interface types | ||
| ● Number of ports | 3; RJ45 | |
| ● integrated switch | Yes | |
| Protocols | ||
| ● MPI | No | |
| ● PROFINET IO Controller | Yes; Also simultaneously with IO-Device functionality | |
| ● PROFINET IO Device | Yes; Also simultaneously with IO Controller functionality | |
| ● PROFINET CBA | Yes | |
| ● PROFIBUS DP master | No | |
| ● PROFIBUS DP slave | No | |
| ● Open IE communication | Yes; Via TCP/IP, ISO on TCP, and UDP | |
| ● Web server | Yes | |
| ● Point-to-point connection | No | |
| PROFINET IO Controller | ||
| ● Transmission rate, max. | 100 Mbit/s; full duplex | |
| Services | ||
| — PG/OP communication | Yes | |
| — Routing | Yes; With DP master module | |
| — S7 communication | Yes; with loadable FBs | |
| — Isochronous mode | Yes; OB 61; only for PROFINET IO | |
| — IRT | Yes | |
| — MRP | Yes | |
| — Shared device | Yes | |
| — Prioritized startup | Yes | |
| — Number of IO devices with prioritized startup, max. | 32 | |
| — Number of connectable IO Devices, max. | 128 | |
| — Of which IO devices with IRT, max. | 64 | |
| — of which in line, max. | 64 | |
| — Number of IO Devices with IRT and the option "high flexibility" | 128 | |
| — of which in line, max. | 61 | |
| — Number of connectable IO Devices for RT, max. | 128 | |
| — of which in line, max. | 128 | |
| — Activation/deactivation of IO Devices | Yes | |
| — Number of IO Devices that can be simultaneously activated/deactivated, max. | 8 | |
| — IO Devices changing during operation (partner ports), supported | Yes | |
| — Number of IO Devices per tool, max. | 8 | |
| — Device replacement without swap medium | Yes | |
| — Send cycles | 250 μs, 500 μs,1 ms; 2 ms, 4 ms (not in the case of IRT with "high flexibility" option) | |
| — Updating time | Minimum value depends on communication share set for PROFINET I/O, on the number of I/O devices, and on the number of configured user data items. | |
| — Updating times | 250 µs to 512 ms (depends on operating mode; for more details, refer to Operating Instructions, "Interface Module IM151-8 PN/DP CPU") | |
| Address area | ||
| — Inputs, max. | 2 kbyte | |
| — Outputs, max. | 2 kbyte | |
| — User data consistency, max. | 1 024 byte; with PROFINET I/O | |
| PROFINET IO Device | ||
| Services | ||
| — PG/OP communication | Yes | |
| — Routing | Yes | |
| — S7 communication | Yes; with loadable FBs | |
| — Isochronous mode | No | |
| — IRT | Yes | |
| — MRP | Yes | |
| — PROFIenergy | Yes; With SFB 73 / 74 prepared for loadable PROFIenergy standard FB for I-Device | |
| — Shared device | Yes | |
| — Number of IO Controllers with shared device, max. | 2 | |
| Transfer memory | ||
| — Inputs, max. | 1 440 byte; Per IO Controller with shared device | |
| — Outputs, max. | 1 440 byte; Per IO Controller with shared device | |
| Submodules | ||
| — Number, max. | 64 | |
| — User data per submodule, max. | 1 024 byte | |
| PROFINET CBA | ||
| ● acyclic transmission | Yes | |
| ● cyclic transmission | Yes | |
| Open IE communication | ||
| ● Number of connections, max. | 8 | |
| ● Local port numbers used at the system end | 0, 20, 21, 23, 25, 80, 102, 135, 161, 443, 8080, 34962, 34963, 34964, 65532, 65533, 65534, 65535 | |
| 2. Interface | ||
| Interface type | External interface via master module 6ES7138-4HA00-0AB0 | |
| Physics | RS 485 | |
| Isolated | Yes | |
| Power supply to interface (15 to 30 V DC), max. | No | |
| Protocols | ||
| ● MPI | No | |
| ● PROFINET IO Controller | No | |
| ● PROFINET IO Device | No | |
| ● PROFINET CBA | No | |
| ● PROFIBUS DP master | Yes | |
| ● PROFIBUS DP slave | No | |
| ● Open IE communication | No | |
| ● Web server | No | |
| PROFIBUS DP master | ||
| ● Transmission rate, max. | 12 Mbit/s | |
| ● Number of DP slaves, max. | 32; Per station | |
| Services | ||
| — PG/OP communication | Yes | |
| — Routing | Yes | |
| — Global data communication | No | |
| — S7 basic communication | Yes; I blocks only | |
| — S7 communication | Yes | |
| — S7 communication, as client | No | |
| — S7 communication, as server | Yes | |
| — Equidistance | Yes | |
| — Isochronous mode | No | |
| — SYNC/FREEZE | Yes | |
| — Activation/deactivation of DP slaves | Yes | |
| — Number of DP slaves that can be simultaneously activated/deactivated, max. | 8 | |
| — Direct data exchange (slave-to-slave communication) | Yes | |
| — DPV1 | Yes | |
| Address area | ||
| — Inputs, max. | 2 048 byte | |
| — Outputs, max. | 2 048 byte | |
| User data per DP slave | ||
| — Inputs, max. | 244 byte | |
| — Outputs, max. | 244 byte | |
| Protocols | ||
| Redundancy mode | ||
| Media redundancy | ||
| — Switchover time on line break, typ. | 200 ms; PROFINET MRP | |
| — Number of stations in the ring, max. | 50 | |
| Open IE communication | ||
| ● TCP/IP | Yes; via integrated PROFINET interface and loadable FBs | |
| — Number of connections, max. | 8 | |
| — Data length for connection type 01H, max. | 1 460 byte | |
| — Data length for connection type 11H, max. | 32 768 byte | |
| — several passive connections per port, supported | Yes | |
| ● ISO-on-TCP (RFC1006) | Yes; via integrated PROFINET interface and loadable FBs | |
| — Number of connections, max. | 8 | |
| — Data length, max. | 32 768 byte | |
| ● UDP | Yes; via integrated PROFINET interface and loadable FBs | |
| — Number of connections, max. | 8 | |
| — Data length, max. | 1 472 byte | |
| Web server | ||
| ● supported | Yes | |
| ● User-defined websites | Yes | |
| ● Number of HTTP clients | 5 | |
| Communication functions | ||
| PG/OP communication | Yes | |
| Data record routing | Yes; With DP master module | |
| Global data communication | ||
| ● supported | No | |
| S7 basic communication | ||
| ● supported | Yes; I blocks | |
| ● User data per job, max. | 76 byte | |
| ● User data per job (of which consistent), max. | 76 byte | |
| S7 communication | ||
| ● supported | Yes | |
| ● as server | Yes | |
| ● as client | Yes; via integrated PROFINET interface and loadable FBs | |
| ● User data per job, max. | See online help of STEP 7 (shared parameters of the SFBs/FBs and of the SFCs/FCs of S7 Communication) | |
| PROFINET CBA (at set setpoint communication load) | ||
| ● Setpoint for the CPU communication load | 50 % | |
| ● Number of remote interconnection partners | 32 | |
| ● Number of functions, master/slave | 30 | |
| ● Total of all master/slave connections | 1 000 | |
| ● Data length of all incoming connections master/slave, max. | 4 000 byte | |
| ● Data length of all outgoing connections master/slave, max. | 4 000 byte | |
| ● Number of device-internal and PROFIBUS interconnections | 500 | |
| ● Data length of device-internal und PROFIBUS interconnections, max. | 4 000 byte | |
| ● Data length per connection, max. | 1 400 byte | |
| Remote interconnections with acyclic transmission | ||
| — Sampling interval, min. | 500 ms | |
| — Number of incoming interconnections | 100 | |
| — Number of outgoing interconnections | 100 | |
| — Data length of all incoming interconnections, max. | 2 000 byte | |
| — Data length of all outgoing interconnections, max. | 2 000 byte | |
| — Data length per connection, max. | 1 400 byte | |
| Remote interconnections with cyclic transmission | ||
| — Transmission frequency: Transmission interval, min. | 1 ms | |
| — Number of incoming interconnections | 200 | |
| — Number of outgoing interconnections | 200 | |
| — Data length of all incoming interconnections, max. | 2 000 byte | |
| — Data length of all outgoing interconnections, max. | 2 000 byte | |
| — Data length per connection, max. | 450 byte | |
| HMI variables via PROFINET (acyclic) | ||
| — Number of stations that can log on for HMI variables (PN OPC/iMap) | 3; 2x PN OPC/1x iMap | |
| — HMI variable updating | 500 ms | |
| — Number of HMI variables | 200 | |
| — Data length of all HMI variables, max. | 2 000 byte | |
| PROFIBUS proxy functionality | ||
| — supported | Yes | |
| — Number of linked PROFIBUS devices | 16 | |
| — Data length per connection, max. | 240 byte; Slave-dependent | |
| iPAR server | ||
| ● supported | Yes | |
| Number of connections | ||
| ● overall | 12 | |
| ● usable for PG communication | 11 | |
| — reserved for PG communication | 1 | |
| — adjustable for PG communication, min. | 1 | |
| — adjustable for PG communication, max. | 11 | |
| ● usable for OP communication | 11 | |
| — reserved for OP communication | 1 | |
| — adjustable for OP communication, min. | 1 | |
| — adjustable for OP communication, max. | 11 | |
| ● usable for S7 basic communication | 10 | |
| — reserved for S7 basic communication | 0 | |
| — adjustable for S7 basic communication, min. | 0 | |
| — adjustable for S7 basic communication, max. | 10 | |
| ● usable for S7 communication | 10; with loadable FBs | |
| — adjustable for S7 communication, max. | 10 | |
| ● total number of instances, max. | 32 | |
| ● usable for routing | 4; max. | |
| S7 message functions | ||
| Number of login stations for message functions, max. | 12; Depending on the configured connections for PG/OP and S7 basic communication | |
| Process diagnostic messages | Yes; ALARM_S, ALARM_SC, ALARM_SQ, ALARM_D, ALARM_DQ | |
| simultaneously active Alarm-S blocks, max. | 300 | |
| Test commissioning functions | ||
| Status block | Yes; Up to 2 simultaneously | |
| Single step | Yes | |
| Number of breakpoints | 4 | |
| Status/control | ||
| ● Status/control variable | Yes | |
| ● Variables | Inputs, outputs, memory bits, DB, times, counters | |
| ● Number of variables, max. | 30 | |
| — of which status variables, max. | 30 | |
| — of which control variables, max. | 14 | |
| Forcing | ||
| ● Forcing | Yes | |
| ● Forcing, variables | I/O | |
| ● Number of variables, max. | 10 | |
| Diagnostic buffer | ||
| ● present | Yes | |
| ● Number of entries, max. | 500 | |
| — adjustable | No | |
| — of which powerfail-proof | 100; Only the last 100 entries are retained | |
| Interrupts/diagnostics/status information | ||
| Alarms | Yes | |
| Diagnostics function | Yes | |
| Diagnostics indication LED | ||
| ● for maintenance | Yes; MT | |
| ● Bus fault BF (red) | Yes; BF-PN | |
| ● Group error SF (red) | Yes | |
| ● Monitoring 24 V voltage supply ON (green) | Yes | |
| ● Bus activity PROFINET (green) | Yes; P1-/P2-/P3-Link | |
| Potential separation | ||
| between PROFIBUS DP and all other circuit components | Yes | |
| Isolation | ||
| Isolation tested with | 500 V DC | |
| Degree and class of protection | ||
| IP degree of protection | IP20 | |
| Configuration | ||
| Configuration software | ||
| ● STEP 7 | Yes; V5.5 or higher | |
| Programming | ||
| ● Command set | see instruction list | |
| ● Nesting levels | 8 | |
| ● System functions (SFC) | see instruction list | |
| ● System function blocks (SFB) | see instruction list | |
| Programming language | ||
| — LAD | Yes | |
| — FBD | Yes | |
| — STL | Yes | |
| — SCL | Yes; Optional | |
| — CFC | Yes; Optional | |
| — GRAPH | Yes; Optional | |
| — HiGraph® | Yes; Optional | |
| Know-how protection | ||
| ● User program protection/password protection | Yes | |
| ● Block encryption | Yes; With S7 block Privacy | |
| Cycle time monitoring | ||
| ● lower limit | 1 ms | |
| ● upper limit | 6 000 ms | |
| ● adjustable | Yes | |
| ● preset | 150 ms | |
| Dimensions | ||
| Width | 120 mm; DP master module: 35 mm | |
| Height | 119.5 mm | |
| Depth | 75 mm | |
| Weights | ||
| Weight, approx. | 320 g; DP master module: Approx. 100 g | |
| last modified: | 08/28/2020 | |
| Product | ||||||||||||||||||||||||||||||||||||||||
| Article Number (Market Facing Number) | 6ES7151-8FB01-0AB0 | |||||||||||||||||||||||||||||||||||||||
| Product Description | SIMATIC DP, IM151-8F PN/DP CPU f. ET200S, 256 KB work memory, int. PROFINET interface (with three RJ45 ports) as IO controller/I-device without battery, MMC required | |||||||||||||||||||||||||||||||||||||||
| Product family | IM 151-8 F PN/DP CPU | |||||||||||||||||||||||||||||||||||||||
| Product Lifecycle (PLM) | PM300:Active Product | |||||||||||||||||||||||||||||||||||||||
| Price data | ||||||||||||||||||||||||||||||||||||||||
| Price Group | 241 | |||||||||||||||||||||||||||||||||||||||
| Surcharge for Raw Materials | None | |||||||||||||||||||||||||||||||||||||||
| Metal Factor | None | |||||||||||||||||||||||||||||||||||||||
| Delivery information | ||||||||||||||||||||||||||||||||||||||||
| Export Control Regulations | AL : N / ECCN : EAR99H | |||||||||||||||||||||||||||||||||||||||
| Standard lead time ex-works | 10 Day/Days | |||||||||||||||||||||||||||||||||||||||
| Net Weight (kg) | 0,396 Kg | |||||||||||||||||||||||||||||||||||||||
| Product Dimensions (W x L x H) | Not available | |||||||||||||||||||||||||||||||||||||||
| Packaging Dimension | 13,20 x 15,30 x 9,10 | |||||||||||||||||||||||||||||||||||||||
| Package size unit of measure | CM | |||||||||||||||||||||||||||||||||||||||
| Quantity Unit | 1 Piece | |||||||||||||||||||||||||||||||||||||||
| Packaging Quantity | 1 | |||||||||||||||||||||||||||||||||||||||
| Additional Product Information | ||||||||||||||||||||||||||||||||||||||||
| EAN | 4025515078753 | |||||||||||||||||||||||||||||||||||||||
| UPC | 040892692839 | |||||||||||||||||||||||||||||||||||||||
| Commodity Code | 85389091 | |||||||||||||||||||||||||||||||||||||||
| LKZ_FDB/ CatalogID | ST76 | |||||||||||||||||||||||||||||||||||||||
| Product Group | 4A9E | |||||||||||||||||||||||||||||||||||||||
| Group Code | R111 | |||||||||||||||||||||||||||||||||||||||
| Country of origin | Germany | |||||||||||||||||||||||||||||||||||||||
| Compliance with the substance restrictions according to RoHS directive | Since: 21.05.2010 | |||||||||||||||||||||||||||||||||||||||
| Product class | A: Standard product which is a stock item could be returned within the returns guidelines/period. | |||||||||||||||||||||||||||||||||||||||
| WEEE (2012/19/EU) Take-Back Obligation | Yes | |||||||||||||||||||||||||||||||||||||||
| REACH Art. 33 Duty to inform according to the current list of candidates |
| |||||||||||||||||||||||||||||||||||||||