View larger
6EP1961-3BA01 SIEMENS SITOP PSE201U buffer module Buffer time 100 ms to 10 s Depending on load current
6EP1961-3BA01
19613
SIEMENS
1 Pcs.
Automation > UPS
Power supplies
Product condition, packaging, certifications and applicable manufacturer warranty terms are confirmed with the quotation.
Request a Quote
Pricing and availability are confirmed for each enquiry. Send this part and we will reply with price and lead time.
Request QuoteProduct Overview
This Siemens buffer module bridges short-term power dips to protect automation electronics and maintain control stability during grid fluctuations. It extends system uptime by supplying temporary electrical energy from internal storage. Pricing, availability and lead time are confirmed per enquiry through an RFQ.
- Product Article Number (Market Facing Number): 6EP1961-3BA01
- Product family: Buffer module
- Product Lifecycle (PLM): PM300:Active Product
- Delivery information Export Control Regulations: AL : N / ECCN : N
- Standard lead time ex-works: 20 Day/Days
- Net Weight (kg): 1,200 Kg
- Packaging Dimension: 13,50 x 13,50 x 8,00
- Package size unit of measure: CM
- Quantity Unit: 1 Piece
- Packaging Quantity: 1
- Additional Product Information EAN: 4025515152576
- UPC: Not available
- Commodity Code: 85049090
- LKZ_FDB/ CatalogID: KT10-PE
- Product Group: 4216
- Group Code: R315
More info
▲Additional data
| Product | ||||||||||||||||||||||||||||||||||||||||
| Article Number (Market Facing Number) | 6EP1961-3BA01 | |||||||||||||||||||||||||||||||||||||||
| Product Description | SITOP PSE201U buffer module Buffer time 100 ms to 10 s depending on load current *Ex approval no longer available* | |||||||||||||||||||||||||||||||||||||||
| Product family | Buffer module | |||||||||||||||||||||||||||||||||||||||
| Product Lifecycle (PLM) | PM300:Active Product | |||||||||||||||||||||||||||||||||||||||
| Price data | ||||||||||||||||||||||||||||||||||||||||
| Region Specific PriceGroup / Headquarter Price Group | 588 / 588 | |||||||||||||||||||||||||||||||||||||||
| Surcharge for Raw Materials | None | |||||||||||||||||||||||||||||||||||||||
| Metal Factor | None | |||||||||||||||||||||||||||||||||||||||
| Delivery information | ||||||||||||||||||||||||||||||||||||||||
| Export Control Regulations | AL : N / ECCN : N | |||||||||||||||||||||||||||||||||||||||
| Standard lead time ex-works | 20 Day/Days | |||||||||||||||||||||||||||||||||||||||
| Net Weight (kg) | 1,200 Kg | |||||||||||||||||||||||||||||||||||||||
| Packaging Dimension | 13,50 x 13,50 x 8,00 | |||||||||||||||||||||||||||||||||||||||
| Package size unit of measure | CM | |||||||||||||||||||||||||||||||||||||||
| Quantity Unit | 1 Piece | |||||||||||||||||||||||||||||||||||||||
| Packaging Quantity | 1 | |||||||||||||||||||||||||||||||||||||||
| Additional Product Information | ||||||||||||||||||||||||||||||||||||||||
| EAN | 4025515152576 | |||||||||||||||||||||||||||||||||||||||
| UPC | Not available | |||||||||||||||||||||||||||||||||||||||
| Commodity Code | 85049090 | |||||||||||||||||||||||||||||||||||||||
| LKZ_FDB/ CatalogID | KT10-PE | |||||||||||||||||||||||||||||||||||||||
| Product Group | 4216 | |||||||||||||||||||||||||||||||||||||||
| Group Code | R315 | |||||||||||||||||||||||||||||||||||||||
| Country of origin | Austria | |||||||||||||||||||||||||||||||||||||||
| Compliance with the substance restrictions according to RoHS directive | Since: 16.06.2009 | |||||||||||||||||||||||||||||||||||||||
| Product class | A: Standard product which is a stock item could be returned within the returns guidelines/period. | |||||||||||||||||||||||||||||||||||||||
| WEEE (2012/19/EU) Take-Back Obligation | Yes | |||||||||||||||||||||||||||||||||||||||
| REACH Art. 33 Duty to inform according to the current list of candidates |
| |||||||||||||||||||||||||||||||||||||||
| Classifications | ||||||||||||||||||||||||||||||||||||||||
| ||||||||||||||||||||||||||||||||||||||||
ETIM data
ETIM: EC000382 - UPS
| Value | Unit | |
|---|---|---|
| Output voltage (EF003933) | - | V |
| Output effective power (EF009897) | - | W |
| Input voltage (EF003840) | ['24', '24'] | V |
| Primary frequency (EF009272) | ['-', '-'] | Hz |
| Number of phases primary (EF009275) | - | |
| Secondary frequency (EF009273) | ['-', '-'] | Hz |
| Output apparent power (EF009898) | - | VA |
| Type of interface (EF006977) | None | |
| Number of phases secondary (EF009274) | - | |
| SNMP (EF005284) | FALSE | |
| Voltage type (EF000187) | DC | |
| Height (EF000040) | 125.0 | mm |
| Width (EF000008) | 70.0 | mm |
| Depth (EF000049) | 125.0 | mm |
| Bridging time full load (EF000428) | 0.166666667 | min |
| Weight (EF000167) | 1200.0 | kg |
| Suitable for network-management (EF000432) | false | |
| USV- technology (EF005380) | Offline | |
| Construction type (EF000767) | - | |
| Max. voltage distortion output (linear load) (EF009404) | - | % |
| Output power factor (EF009405) | - | |
| Overall efficiency (EF009406) | - | % |
| Efficiency in eco-mode (EF009407) | - | % |
| Potential free switch contact (EF003626) | - | |
| Auto shut down function (EF009276) | - | |
| Input connection (EF009726) | - | |
| Number of output connections C13 (EF009727) | - | |
| Number of output connections C19 (EF009728) | - | |
| Number of output connections with protective contact (SCHUKO) (EF009729) | - | |
| Number of output connections fixed connection (EF009730) | - |