View larger
5TT4125-0 SIEMENS Remote control switch with 1 NO contact, and 1 NC with central ON/OFF function Contact for..
5TT4125-0
41250
SIEMENS
1 Pcs.
Automation > Latching relay
Other Modular Systems
Product condition, packaging, certifications and applicable manufacturer warranty terms are confirmed with the quotation.
Request a Quote
Pricing and availability are confirmed for each enquiry. Send this part and we will reply with price and lead time.
Request QuoteProduct Overview
The Siemens remote control switch, designated by part number 5TT4125-0, is an electromechanical component engineered for pulse-activated load switching in complex electrical installations. Engineers typically deploy these devices within building automation systems to handle grouped switching commands and reduce continuous coil energization.
Pricing, availability and lead time are confirmed per enquiry through an RFQ.
- product designation: Remote control switch
- latching relay design: mechanical for central control
- galvanic isolation / between magnet coil and contact: Yes
- switching voltage / of the contacts / at AC / minimum: 10 V
- switching current / at AC / per contact / minimum: 100 mA
- power loss [V∙A] / of magnet coil / with pulse / rated value: 7 VA
- Voltage type of voltage / of the operating voltage: AC
- continuous voltage fuse version: Yes
- ● initial value: 0.8
- ● full-scale value: 1.1
- surge voltage resistance / rated value: 4 kV
- supply voltage: 250 V
- Supply voltage supply voltage / minimum: 250 V
- Protection class protection class IP: IP20, with connected conductors
- ● for fluorescent lamp load with DUO circuit: 700 VA
- ● for fluorescent lamp load with parallel compensation: 300 VA
More info
▲Technical data
Additional data
| Product | |||||||||||||||||||||||||||||||
| Article Number (Market Facing Number) | 5TT4125-0 | ||||||||||||||||||||||||||||||
| Product Description | Remote control switch with 1 NO contact, and 1 NC with central ON/OFF function Contact for 230 V AC, 400V 16A Control 230 V AC | ||||||||||||||||||||||||||||||
| Product family | SENTRON 5TT4 Remote Control Switches | ||||||||||||||||||||||||||||||
| Product Lifecycle (PLM) | PM300:Active Product | ||||||||||||||||||||||||||||||
| Price data | |||||||||||||||||||||||||||||||
| Region Specific PriceGroup / Headquarter Price Group | 12F / 1BK | ||||||||||||||||||||||||||||||
| Surcharge for Raw Materials | None | ||||||||||||||||||||||||||||||
| Metal Factor | L-P----- | ||||||||||||||||||||||||||||||
| Delivery information | |||||||||||||||||||||||||||||||
| Export Control Regulations | AL : N / ECCN : EAR99 | ||||||||||||||||||||||||||||||
| Standard lead time ex-works | 1 Day/Days | ||||||||||||||||||||||||||||||
| Net Weight (kg) | 0,167 Kg | ||||||||||||||||||||||||||||||
| Packaging Dimension | 30,00 x 93,00 x 84,00 | ||||||||||||||||||||||||||||||
| Package size unit of measure | MM | ||||||||||||||||||||||||||||||
| Quantity Unit | 1 Piece | ||||||||||||||||||||||||||||||
| Packaging Quantity | 1 | ||||||||||||||||||||||||||||||
| Additional Product Information | |||||||||||||||||||||||||||||||
| EAN | 4001869312606 | ||||||||||||||||||||||||||||||
| UPC | Not available | ||||||||||||||||||||||||||||||
| Commodity Code | 85365080 | ||||||||||||||||||||||||||||||
| LKZ_FDB/ CatalogID | LV10.1 | ||||||||||||||||||||||||||||||
| Product Group | 5528 | ||||||||||||||||||||||||||||||
| Group Code | P310 | ||||||||||||||||||||||||||||||
| Country of origin | Romania | ||||||||||||||||||||||||||||||
| Compliance with the substance restrictions according to RoHS directive | Since: 01.07.2006 | ||||||||||||||||||||||||||||||
| Product class | B: return restricted, please contact your Siemens partner/contact | ||||||||||||||||||||||||||||||
| WEEE (2012/19/EU) Take-Back Obligation | Yes | ||||||||||||||||||||||||||||||
| REACH Art. 33 Duty to inform according to the current list of candidates |
| ||||||||||||||||||||||||||||||
| Classifications | |||||||||||||||||||||||||||||||
| |||||||||||||||||||||||||||||||
ETIM data
ETIM: EC000188 - Latching relay
| Value | Unit | |
|---|---|---|
| Function (EF000030) | Mechanical for centralized control | |
| Mounting method (EF000003) | DIN rail | |
| Width in number of modular spacings (EF002950) | 1.5 | |
| Built-in depth (EF000218) | 70.0 | mm |
| Number of contacts as normally open contact (EF008256) | 1 | |
| Number of contacts as normally closed contact (EF008255) | 1 | |
| Number of contacts as change-over contact (EF008257) | 0 | |
| Control voltage 1 (EF002952) | ['184', '253'] | V |
| Type of control voltage 1 (EF002954) | AC | |
| Frequency control voltage 1 (EF002956) | ['50.0', '50.0'] | Hz |
| Control voltage 2 (EF002953) | ['184', '253'] | V |
| Type of control voltage 2 (EF002955) | AC | |
| Frequency control voltage 2 (EF002957) | ['50.0', '50.0'] | Hz |
| Rated switch current (EF006706) | 16 | A |
| Supply voltage (EF004127) | ['250', '250'] | V |
| Voltage type of supply voltage (EF002991) | AC | |
| Max. incandescent lamp load (EF004952) | 2000 | W |
| Max. load fluorescent lamp (EF004971) | 400 | VA |
| Max. load fluorescent lamp (Duo circuit) (EF004972) | 700 | VA |
| Max. load fluorescent lamp (parallel compensated) (EF004973) | 300 | VA |
| Max. switching current (cos phi = 0.6) (EF004920) | 16 | A |
| Manual operation possible (EF005881) | true |