View larger
5SY4415-5 SIEMENS Miniature circuit breaker 400 V 10kA, 4-pole, A, 1.6 A, D 70 mm
5SY4415-5
44155
SIEMENS
1 Pcs.
Automation > Miniature circuit breaker (MCB)
Industrial circuit breakers from 6 kA
Product condition, packaging, certifications and applicable manufacturer warranty terms are confirmed with the quotation.
Request a Quote
Pricing and availability are confirmed for each enquiry. Send this part and we will reply with price and lead time.
Request QuoteProduct Overview
Siemens 5SY4415-5 is a miniature circuit breaker used in building management systems and machine control panels to protect electrical circuits against overcurrent conditions and potential short circuits.
Pricing, availability, and lead time are confirmed per enquiry through an RFQ.
- Product Article Number (Market Facing Number): 5SY4415-5
- Product Description: Miniature circuit breaker 400 V 10kA, 4-pole, A, 1.6 A, D=70 mm
- Product family: Basic Devices
- Product Lifecycle (PLM): PM300:Active Product
- Metal Factor: L-O-----
- Delivery information Export Control Regulations: AL : N / ECCN : N
- Standard lead time ex-works: 95 Day/Days
- Net Weight (kg): 0,649 Kg
- Packaging Dimension: 75,00 x 95,00 x 83,00
- Package size unit of measure: MM
- Quantity Unit: 1 Piece
- Packaging Quantity: 1
- Additional Product Information EAN: 4001869201467
- UPC: Not available
- Commodity Code: 85362010
- LKZ_FDB/ CatalogID: LV10.1
More info
▲Additional data
| Product | |||||||||||||||||||||||||||||||||||||
| Article Number (Market Facing Number) | 5SY4415-5 | ||||||||||||||||||||||||||||||||||||
| Product Description | Miniature circuit breaker 400 V 10kA, 4-pole, A, 1.6 A, D=70 mm | ||||||||||||||||||||||||||||||||||||
| Product family | Basic Devices | ||||||||||||||||||||||||||||||||||||
| Product Lifecycle (PLM) | PM300:Active Product | ||||||||||||||||||||||||||||||||||||
| Price data | |||||||||||||||||||||||||||||||||||||
| Region Specific PriceGroup / Headquarter Price Group | 14A / 1AA | ||||||||||||||||||||||||||||||||||||
| Surcharge for Raw Materials | None | ||||||||||||||||||||||||||||||||||||
| Metal Factor | L-O----- | ||||||||||||||||||||||||||||||||||||
| Delivery information | |||||||||||||||||||||||||||||||||||||
| Export Control Regulations | AL : N / ECCN : N | ||||||||||||||||||||||||||||||||||||
| Standard lead time ex-works | 95 Day/Days | ||||||||||||||||||||||||||||||||||||
| Net Weight (kg) | 0,649 Kg | ||||||||||||||||||||||||||||||||||||
| Packaging Dimension | 75,00 x 95,00 x 83,00 | ||||||||||||||||||||||||||||||||||||
| Package size unit of measure | MM | ||||||||||||||||||||||||||||||||||||
| Quantity Unit | 1 Piece | ||||||||||||||||||||||||||||||||||||
| Packaging Quantity | 1 | ||||||||||||||||||||||||||||||||||||
| Additional Product Information | |||||||||||||||||||||||||||||||||||||
| EAN | 4001869201467 | ||||||||||||||||||||||||||||||||||||
| UPC | Not available | ||||||||||||||||||||||||||||||||||||
| Commodity Code | 85362010 | ||||||||||||||||||||||||||||||||||||
| LKZ_FDB/ CatalogID | LV10.1 | ||||||||||||||||||||||||||||||||||||
| Product Group | 5517 | ||||||||||||||||||||||||||||||||||||
| Group Code | P310 | ||||||||||||||||||||||||||||||||||||
| Country of origin | Germany | ||||||||||||||||||||||||||||||||||||
| Compliance with the substance restrictions according to RoHS directive | Since: 01.10.2006 | ||||||||||||||||||||||||||||||||||||
| Product class | C: products manufactured / produced to order, which cannot be reused or re-utilised or be returned against credit. | ||||||||||||||||||||||||||||||||||||
| WEEE (2012/19/EU) Take-Back Obligation | Yes | ||||||||||||||||||||||||||||||||||||
| REACH Art. 33 Duty to inform according to the current list of candidates |
| ||||||||||||||||||||||||||||||||||||
| Classifications | |||||||||||||||||||||||||||||||||||||
| |||||||||||||||||||||||||||||||||||||
ETIM data
ETIM: EC000042 - Miniature circuit breaker (MCB)
| Value | Unit | |
|---|---|---|
| Rated insulation voltage Ui (EF001366) | - | V |
| Rated impulse withstand voltage Uimp (EF011980) | - | kV |
| Release characteristic (EF000889) | A | |
| Number of poles (total) (EF008618) | 4 | |
| Number of protected poles (EF005548) | 4P | |
| Rated current (EF000227) | 1.6 | A |
| Rated voltage (EF000228) | 400 | V |
| Rated short-circuit breaking capacity Icn EN 60898 at 230 V (EF009556) | 10.0 | kA |
| Rated short-circuit breaking capacity Icn EN 60898 at 400 V (EF009555) | 10.0 | kA |
| Rated short-circuit breaking capacity Icu IEC 60947-2 at 230 V (EF009557) | 35.0 | kA |
| Rated short-circuit breaking capacity Icu IEC 60947-2 at 400 V (EF009558) | 35.0 | kA |
| Voltage type (EF000187) | AC/DC | |
| Frequency (EF000416) | ['50.0', '50.0'] | Hz |
| Current limiting class (EF002568) | 3 | |
| Suitable for flush-mounted installation (EF006573) | false | |
| Concurrently switching N-neutral (EF005997) | false | |
| Over voltage category (EF002569) | 3 | |
| Pollution degree (EF002570) | 3 | |
| Additional equipment possible (EF008148) | true | |
| Width in number of modular spacings (EF002950) | 4 | |
| Built-in depth (EF000218) | 70.0 | mm |
| Degree of protection (IP) (EF005474) | IP20 | |
| Ambient temperature during operating (EF007515) | ['-25', '55'] | °C |
| Connectable conductor cross section multi-wired (EF007343) | ['0.75', '35.0'] | mm² |
| Connectable conductor cross section solid-core (EF007337) | ['0.75', '35.0'] | mm² |