Request QuoteProduct Overview
Utilized alongside evaluation devices, the Siemens 5SV8705-0KK summation current transformer measures vector sums of phase and neutral currents to detect earth faults in heavy electrical installations. This hardware sits centrally within industrial power distribution pathways to capture differential magnetic fields safely and accurately.
Pricing, availability and lead time are confirmed per enquiry through an RFQ.
- product designation: summation current transformer
- design of the product: type A
- residual current (Idn) / minimum: 300 mA
- internal diameter / of summation current transformer: 140 mm
- wire length / maximum: 10 m
- protection class IP / at connection all terminals: IP20
- type of voltage / of the operating voltage / for actuation: AC
- surge voltage resistance / rated value: 4 kV
- ● maximum: 720 V
- starting current / limited to 2 s / maximum: 3 000 A
- ● minimum: 50 Hz
- ● maximum: 60 Hz
- operational current / rated value: 500 A
- ● at AC / at 50 Hz / rated value / maximum: 720 V
- ● at AC / at 60 Hz / rated value / maximum: 720 V
- Product function product function / error memory: No
More info
▲Technical data
Additional data
| Product | |||||||||||||||||||||||||||||||||||||
| Article Number (Market Facing Number) | 5SV8705-0KK | ||||||||||||||||||||||||||||||||||||
| Product Description | Summation current transformer 140 mm | ||||||||||||||||||||||||||||||||||||
| Product family | SENTRON 5SV8 Residual Current Monitors | ||||||||||||||||||||||||||||||||||||
| Product Lifecycle (PLM) | PM300:Active Product | ||||||||||||||||||||||||||||||||||||
| Price data | |||||||||||||||||||||||||||||||||||||
| Region Specific PriceGroup / Headquarter Price Group | 13B / 1BE | ||||||||||||||||||||||||||||||||||||
| Surcharge for Raw Materials | None | ||||||||||||||||||||||||||||||||||||
| Metal Factor | L-A----- | ||||||||||||||||||||||||||||||||||||
| Delivery information | |||||||||||||||||||||||||||||||||||||
| Export Control Regulations | AL : N / ECCN : N | ||||||||||||||||||||||||||||||||||||
| Standard lead time ex-works | 2 Day/Days | ||||||||||||||||||||||||||||||||||||
| Net Weight (kg) | 1,081 Kg | ||||||||||||||||||||||||||||||||||||
| Packaging Dimension | 200,00 x 210,00 x 50,00 | ||||||||||||||||||||||||||||||||||||
| Package size unit of measure | MM | ||||||||||||||||||||||||||||||||||||
| Quantity Unit | 1 Piece | ||||||||||||||||||||||||||||||||||||
| Packaging Quantity | 1 | ||||||||||||||||||||||||||||||||||||
| Additional Product Information | |||||||||||||||||||||||||||||||||||||
| EAN | 4001869397696 | ||||||||||||||||||||||||||||||||||||
| UPC | Not available | ||||||||||||||||||||||||||||||||||||
| Commodity Code | 90309000 | ||||||||||||||||||||||||||||||||||||
| LKZ_FDB/ CatalogID | LV10.1 | ||||||||||||||||||||||||||||||||||||
| Product Group | 5509 | ||||||||||||||||||||||||||||||||||||
| Group Code | P310 | ||||||||||||||||||||||||||||||||||||
| Country of origin | Spain | ||||||||||||||||||||||||||||||||||||
| Compliance with the substance restrictions according to RoHS directive | Since: 01.10.2008 | ||||||||||||||||||||||||||||||||||||
| Product class | B: return restricted, please contact your Siemens partner/contact | ||||||||||||||||||||||||||||||||||||
| WEEE (2012/19/EU) Take-Back Obligation | Yes | ||||||||||||||||||||||||||||||||||||
| REACH Art. 33 Duty to inform according to the current list of candidates |
| ||||||||||||||||||||||||||||||||||||
| Classifications | |||||||||||||||||||||||||||||||||||||
| |||||||||||||||||||||||||||||||||||||
ETIM data
ETIM: EC001445 - Residual current monitoring relay
| Value | Unit | |
|---|---|---|
| Voltage type for actuating (EF008242) | - | |
| With detachable clamps (EF003340) | - | |
| Rated frequency (EF001663) | - | Hz |
| Function (EF000030) | - | |
| Number of contacts as normally open contact (EF008256) | - | |
| Number of contacts as change-over contact (EF008257) | - | |
| Number of contacts as normally closed contact (EF008255) | - | |
| Type of electric connection (EF003961) | Screw connection | |
| Rated control supply voltage Us at DC (EF003980) | ['-', '-'] | V |
| Rated voltage (EF003977) | ['-', '720'] | V |
| Indication of difference current (EF003424) | false | |
| Error registration possible (EF003423) | false | |
| Width (EF000008) | 230.0 | mm |
| Height (EF000040) | 33.0 | mm |
| Depth (EF000049) | 196.0 | mm |
| Response value amperage 1 (EF008204) | - | mA |
| Response value amperage 2 (EF008205) | - | mA |
| Max. permitted delay-on energization time (EF008189) | - | s |
| Min. adjustable delay-on energization time (EF008190) | - | s |
| Rated control supply voltage Us at AC 50HZ (EF003978) | - | V |
| Rated control supply voltage Us at AC 60HZ (EF003979) | - | V |