SIEMENS 5SV5314-0FC 5SV5314-0FC SIEMENS differential switch, 2-pole, AC type, Input: 40 A, 30 mA, One AC: 230 V View larger
Images are for illustrative purposes only. Please refer to data sheet for details

5SV5314-0FC SIEMENS differential switch, 2-pole, AC type, Input: 40 A, 30 mA, One AC: 230 V

5SV5314-0FC

53140

SIEMENS

1 Pcs.

differential switch, 2-pole, AC type, Input: 40 A, 30 mA, One AC: 230 V Class AC differential switch, orange lever, 2 mod., 2 poles, 40 A, 30 mA. Manufactured to order. Non-Cancelable Non-Returnable.

Automation > Residual current circuit breaker (RCCB)
POWER DISTRIBUTION AND LOW VOLTAGE SWITCHGEAR

Product condition, packaging, certifications and applicable manufacturer warranty terms are confirmed with the quotation.

Request a Quote

Pricing and availability are confirmed for each enquiry. Send this part and we will reply with price and lead time.

Request Quote

Product Overview

Circuit protection against insulation faults and hazardous earth currents in building automation setups is provided by a differential switch, such as the Siemens 5SV5314-0FC. This unit constantly supervises current balance across lines to disconnect supplies safely whenever a fault current occurs, minimizing fire and shock risks. Pricing, availability and lead time are confirmed per enquiry through an RFQ.

  • Number of poles (EF001391): 2
  • Rated voltage (EF000228): 230
  • Rated current (EF000227): 40
  • Rated fault current (EF002358): 0.03
  • Mounting method (EF000003): DIN rail
  • Leakage current type (EF002560): AC
  • Selective protection (EF002561): false
  • Short-time delayed tripping (EF003604): false
  • Short-circuit breaking capacity (Icw) (EF002562): 10.0
  • Frequency (EF005455): 50 Hz
  • Additional equipment possible (EF008148): false
  • With interlocking device (EF007385): true
  • Degree of protection (IP) (EF005474): IP20
  • Width in number of modular spacings (EF002950): 2
  • Built-in depth (EF000218): 70.0
  • Ambient temperature during operating (EF007515): ['-25', '45']

More info

▲

ETIM data

ETIM: EC000003 - Residual current circuit breaker (RCCB)

Value Unit
Number of poles (EF001391) 2
Rated voltage (EF000228) 230V
Rated current (EF000227) 40A
Rated fault current (EF002358) 0.03mA
Rated insulation voltage Ui (EF001366) -V
Mounting method (EF000003) DIN rail
Leakage current type (EF002560) AC
Selective protection (EF002561) false
Short-time delayed tripping (EF003604) false
Short-circuit breaking capacity (Icw) (EF002562) 10.0kA
Frequency (EF005455) 50 Hz
Additional equipment possible (EF008148) false
With interlocking device (EF007385) true
Degree of protection (IP) (EF005474) IP20
Width in number of modular spacings (EF002950) 2
Built-in depth (EF000218) 70.0mm
Ambient temperature during operating (EF007515) ['-25', '45']°C
Pollution degree (EF002570) -
Connectable conductor cross section multi-wired (EF007343) ['0.75', '35.0']mm²
Connectable conductor cross section solid-core (EF007337) ['0.75', '35.0']mm²
Surge current capacity (EF002564) -kA
Rated impulse withstand voltage Uimp (EF011980) -kV



Product Datasheet

Electrica Online Product Datasheet Prepared from the current product description, catalog data and structured technical attributes.