View larger
5SV5314-0FB SIEMENS Residual current operated circuit breaker, 2-pole, Type AC, In: 40 A, 30 mA, Un AC: 230 ..
5SV5314-0FB
53140
SIEMENS
1 Pcs.
Automation > Residual current circuit breaker (RCCB)
Tertiary differential switches up to 80 A
Product condition, packaging, certifications and applicable manufacturer warranty terms are confirmed with the quotation.
Request a Quote
Pricing and availability are confirmed for each enquiry. Send this part and we will reply with price and lead time.
Request QuoteProduct Overview
A residual current operated circuit breaker is deployed in distribution enclosures to disconnect circuits automatically when fault currents flow to earth, protecting personnel and property. This Siemens 5SV5314-0FB unit ensures reliable operation in standard two-pole electrical configurations.
Pricing, availability and lead time are confirmed per enquiry through an RFQ.
- Number of poles (EF001391): 2
- Rated voltage (EF000228): 230
- Rated current (EF000227): 40
- Rated fault current (EF002358): 0.03
- Mounting method (EF000003): DIN rail
- Leakage current type (EF002560): AC
- Selective protection (EF002561): false
- Short-time delayed tripping (EF003604): false
- Short-circuit breaking capacity (Icw) (EF002562): 10.0
- Frequency (EF005455): 50 Hz
- Additional equipment possible (EF008148): false
- With interlocking device (EF007385): true
- Degree of protection (IP) (EF005474): IP20
- Width in number of modular spacings (EF002950): 2
- Built-in depth (EF000218): 70.0
- Ambient temperature during operating (EF007515): ['-25', '45']
More info
▲ETIM data
ETIM: EC000003 - Residual current circuit breaker (RCCB)
| Value | Unit | |
|---|---|---|
| Number of poles (EF001391) | 2 | |
| Rated voltage (EF000228) | 230 | V |
| Rated current (EF000227) | 40 | A |
| Rated fault current (EF002358) | 0.03 | mA |
| Rated insulation voltage Ui (EF001366) | - | V |
| Mounting method (EF000003) | DIN rail | |
| Leakage current type (EF002560) | AC | |
| Selective protection (EF002561) | false | |
| Short-time delayed tripping (EF003604) | false | |
| Short-circuit breaking capacity (Icw) (EF002562) | 10.0 | kA |
| Frequency (EF005455) | 50 Hz | |
| Additional equipment possible (EF008148) | false | |
| With interlocking device (EF007385) | true | |
| Degree of protection (IP) (EF005474) | IP20 | |
| Width in number of modular spacings (EF002950) | 2 | |
| Built-in depth (EF000218) | 70.0 | mm |
| Ambient temperature during operating (EF007515) | ['-25', '45'] | °C |
| Pollution degree (EF002570) | - | |
| Connectable conductor cross section multi-wired (EF007343) | ['0.75', '35.0'] | mm² |
| Connectable conductor cross section solid-core (EF007337) | ['0.75', '35.0'] | mm² |
| Surge current capacity (EF002564) | - | kA |
| Rated impulse withstand voltage Uimp (EF011980) | - | kV |