View larger
5SV3612-6 SIEMENS Residual current operated circuit breaker, 2-pole, type A, In: 25 A, 300 mA, Un AC: 230 V
5SV3612-6
36126
SIEMENS
1 Pcs.
Automation > Residual current circuit breaker (RCCB)
Tertiary differential switches up to 80 A
Product condition, packaging, certifications and applicable manufacturer warranty terms are confirmed with the quotation.
Request a Quote
Pricing and availability are confirmed for each enquiry. Send this part and we will reply with price and lead time.
Request QuoteProduct Overview
The Siemens 5SV3612-6 residual current operated circuit breaker functions as a critical safety element within electrical distribution networks, shielding users from indirect contact and minimizing fire risks caused by insulation failure. This modular protective device senses low-magnitude fault currents and rapidly disconnects the power supply. Pricing, availability, and lead time are confirmed per enquiry through an RFQ.
- product designation: RCCB
- design of the product: Instantaneous
- General technical data number of poles: 2
- size of installation devices / according to DIN 43880: 1
- mechanical service life (switching cycles) / typical: 10 000
- short-circuit current / of series fuse / maximum permissible: 63 A
- short-circuit current rating: 10 kA
- switching function / short-term delayed: No
- overvoltage category: III
- value range / of the supply voltage frequency: 50 Hz
- value range / of the operating frequency: 50 Hz
- value range / of the supply voltage / at AC: 230/400 V
- Protection class protection class IP: IP20, if the distribution board is installed, with connected conductors
- ● according to IEC 61008-1 / rated value: 0.5 kA
- ● maximum: 1.2 W
- Current tripping fault current / rated value: 300 mA
More info
▲Technical data
Additional data
| Product | |||||||||||||||||||||||||||||||||||||
| Article Number (Market Facing Number) | 5SV3612-6 | ||||||||||||||||||||||||||||||||||||
| Product Description | Residual current operated circuit breaker, 2-pole, type A, In: 25 A, 300 mA, Un AC: 230 V | ||||||||||||||||||||||||||||||||||||
| Product family | RCCBs | ||||||||||||||||||||||||||||||||||||
| Product Lifecycle (PLM) | PM300:Active Product | ||||||||||||||||||||||||||||||||||||
| Price data | |||||||||||||||||||||||||||||||||||||
| Region Specific PriceGroup / Headquarter Price Group | 11C / 1AH | ||||||||||||||||||||||||||||||||||||
| Surcharge for Raw Materials | None | ||||||||||||||||||||||||||||||||||||
| Metal Factor | L-A----- | ||||||||||||||||||||||||||||||||||||
| Delivery information | |||||||||||||||||||||||||||||||||||||
| Export Control Regulations | AL : N / ECCN : N | ||||||||||||||||||||||||||||||||||||
| Standard lead time ex-works | 70 Day/Days | ||||||||||||||||||||||||||||||||||||
| Net Weight (kg) | 0,187 Kg | ||||||||||||||||||||||||||||||||||||
| Packaging Dimension | 97,00 x 42,00 x 85,00 | ||||||||||||||||||||||||||||||||||||
| Package size unit of measure | MM | ||||||||||||||||||||||||||||||||||||
| Quantity Unit | 1 Piece | ||||||||||||||||||||||||||||||||||||
| Packaging Quantity | 1 | ||||||||||||||||||||||||||||||||||||
| Additional Product Information | |||||||||||||||||||||||||||||||||||||
| EAN | 4001869429717 | ||||||||||||||||||||||||||||||||||||
| UPC | Not available | ||||||||||||||||||||||||||||||||||||
| Commodity Code | 85362010 | ||||||||||||||||||||||||||||||||||||
| LKZ_FDB/ CatalogID | LV10.1 | ||||||||||||||||||||||||||||||||||||
| Product Group | 5511 | ||||||||||||||||||||||||||||||||||||
| Group Code | P310 | ||||||||||||||||||||||||||||||||||||
| Country of origin | Germany | ||||||||||||||||||||||||||||||||||||
| Compliance with the substance restrictions according to RoHS directive | Since: 01.06.2006 | ||||||||||||||||||||||||||||||||||||
| Product class | A: Standard product which is a stock item could be returned within the returns guidelines/period. | ||||||||||||||||||||||||||||||||||||
| WEEE (2012/19/EU) Take-Back Obligation | Yes | ||||||||||||||||||||||||||||||||||||
| REACH Art. 33 Duty to inform according to the current list of candidates |
| ||||||||||||||||||||||||||||||||||||
| Classifications | |||||||||||||||||||||||||||||||||||||
| |||||||||||||||||||||||||||||||||||||
ETIM data
ETIM: EC000003 - Residual current circuit breaker (RCCB)
| Value | Unit | |
|---|---|---|
| Number of poles (EF001391) | 2 | |
| Rated voltage (EF000228) | 230 | V |
| Rated current (EF000227) | 25 | A |
| Rated fault current (EF002358) | 0.3 | mA |
| Rated insulation voltage Ui (EF001366) | - | V |
| Mounting method (EF000003) | DIN rail | |
| Leakage current type (EF002560) | A | |
| Selective protection (EF002561) | false | |
| Short-time delayed tripping (EF003604) | false | |
| Short-circuit breaking capacity (Icw) (EF002562) | 10.0 | kA |
| Surge current capacity (EF002564) | 1.0 | kA |
| Frequency (EF005455) | 50 Hz | |
| Additional equipment possible (EF008148) | true | |
| With interlocking device (EF007385) | true | |
| Degree of protection (IP) (EF005474) | IP20 | |
| Width in number of modular spacings (EF002950) | 2 | |
| Built-in depth (EF000218) | 70.0 | mm |
| Ambient temperature during operating (EF007515) | ['-25', '45'] | °C |
| Pollution degree (EF002570) | - | |
| Connectable conductor cross section multi-wired (EF007343) | ['0.75', '35.0'] | mm² |
| Connectable conductor cross section solid-core (EF007337) | ['0.75', '35.0'] | mm² |
| Rated impulse withstand voltage Uimp (EF011980) | - | kV |