View larger
5SV3342-6KL SIEMENS Residual current operated circuit breaker, 4-pole, type A, In: 25 A, 30 mA, Un AC: 400 V..
5SV3342-6KL
33426
SIEMENS
1 Pcs.
Automation > Residual current circuit breaker (RCCB)
Tertiary differential switches up to 80 A
Product condition, packaging, certifications and applicable manufacturer warranty terms are confirmed with the quotation.
Request a Quote
Pricing and availability are confirmed for each enquiry. Send this part and we will reply with price and lead time.
Request QuoteProduct Overview
Residual current operated circuit breaker, 4-pole, type A, In: 25 A, 30 mA, Un AC: 400 V.. offered by Siemens under part number 5SV3342-6KL acts as a protective switching device designed to safeguard installations against dangerous residual currents. These circuit breakers are widely applied in commercial and industrial electrical distribution boards to ensure compliance with safety regulations. Pricing, availability and lead time are confirmed per enquiry through an RFQ.
- product designation: RCCB
- design of the product: Instantaneous
- product variations: N left
- General technical data number of poles: 4
- size of installation devices / according to DIN 43880: 1
- mechanical service life (switching cycles) / typical: 10 000
- short-circuit current / of series fuse / maximum permissible: 80 A
- short-circuit current rating: 10 kA
- switching function / short-term delayed: No
- overvoltage category: III
- ● at AC / rated value: 400 V
- ● for testing equipment / minimum: 195 V
- value range / of the supply voltage frequency: 50 Hz
- operating frequency: 50 Hz
- supply voltage frequency / rated value: 50 Hz
- value range / of the operating frequency: 50 Hz
More info
▲Technical data
Additional data
| Product | |||||||||||||||||||||||||||||||||||||
| Article Number (Market Facing Number) | 5SV3342-6KL | ||||||||||||||||||||||||||||||||||||
| Product Description | Residual current operated circuit breaker, 4-pole, type A, In: 25 A, 30 mA, Un AC: 400 V, N left | ||||||||||||||||||||||||||||||||||||
| Product family | RCCBs | ||||||||||||||||||||||||||||||||||||
| Product Lifecycle (PLM) | PM300:Active Product | ||||||||||||||||||||||||||||||||||||
| Price data | |||||||||||||||||||||||||||||||||||||
| Region Specific PriceGroup / Headquarter Price Group | 11C / 1AH | ||||||||||||||||||||||||||||||||||||
| Surcharge for Raw Materials | None | ||||||||||||||||||||||||||||||||||||
| Metal Factor | L-A----- | ||||||||||||||||||||||||||||||||||||
| Delivery information | |||||||||||||||||||||||||||||||||||||
| Export Control Regulations | AL : N / ECCN : N | ||||||||||||||||||||||||||||||||||||
| Standard lead time ex-works | 70 Day/Days | ||||||||||||||||||||||||||||||||||||
| Net Weight (kg) | 0,316 Kg | ||||||||||||||||||||||||||||||||||||
| Packaging Dimension | 97,00 x 78,00 x 85,00 | ||||||||||||||||||||||||||||||||||||
| Package size unit of measure | MM | ||||||||||||||||||||||||||||||||||||
| Quantity Unit | 1 Piece | ||||||||||||||||||||||||||||||||||||
| Packaging Quantity | 1 | ||||||||||||||||||||||||||||||||||||
| Additional Product Information | |||||||||||||||||||||||||||||||||||||
| EAN | 4001869430119 | ||||||||||||||||||||||||||||||||||||
| UPC | Not available | ||||||||||||||||||||||||||||||||||||
| Commodity Code | 85362010 | ||||||||||||||||||||||||||||||||||||
| LKZ_FDB/ CatalogID | LV10.1 | ||||||||||||||||||||||||||||||||||||
| Product Group | 5511 | ||||||||||||||||||||||||||||||||||||
| Group Code | P310 | ||||||||||||||||||||||||||||||||||||
| Country of origin | Germany | ||||||||||||||||||||||||||||||||||||
| Compliance with the substance restrictions according to RoHS directive | Since: 01.06.2006 | ||||||||||||||||||||||||||||||||||||
| Product class | A: Standard product which is a stock item could be returned within the returns guidelines/period. | ||||||||||||||||||||||||||||||||||||
| WEEE (2012/19/EU) Take-Back Obligation | Yes | ||||||||||||||||||||||||||||||||||||
| REACH Art. 33 Duty to inform according to the current list of candidates |
| ||||||||||||||||||||||||||||||||||||
| Classifications | |||||||||||||||||||||||||||||||||||||
| |||||||||||||||||||||||||||||||||||||
ETIM data
ETIM: EC000003 - Residual current circuit breaker (RCCB)
| Value | Unit | |
|---|---|---|
| Number of poles (EF001391) | 4 | |
| Rated voltage (EF000228) | 400 | V |
| Rated current (EF000227) | 25 | A |
| Rated fault current (EF002358) | 0.03 | mA |
| Rated insulation voltage Ui (EF001366) | - | V |
| Mounting method (EF000003) | DIN rail | |
| Leakage current type (EF002560) | A | |
| Selective protection (EF002561) | false | |
| Short-time delayed tripping (EF003604) | false | |
| Short-circuit breaking capacity (Icw) (EF002562) | 10.0 | kA |
| Surge current capacity (EF002564) | 1.0 | kA |
| Frequency (EF005455) | 50 Hz | |
| Additional equipment possible (EF008148) | true | |
| With interlocking device (EF007385) | true | |
| Degree of protection (IP) (EF005474) | IP20 | |
| Width in number of modular spacings (EF002950) | 4 | |
| Built-in depth (EF000218) | 70.0 | mm |
| Ambient temperature during operating (EF007515) | ['-25', '45'] | °C |
| Pollution degree (EF002570) | - | |
| Connectable conductor cross section multi-wired (EF007343) | ['0.75', '35.0'] | mm² |
| Connectable conductor cross section solid-core (EF007337) | ['0.75', '35.0'] | mm² |
| Rated impulse withstand voltage Uimp (EF011980) | - | kV |