View larger
5SM2636-8 SIEMENS RC unit for 5SL4, 3-pole, type A, selective, In: 63 A, 300 mA, Un AC: 400 V
5SM2636-8
26368
SIEMENS
1 Pcs.
Automation > Residual current circuit breaker (RCCB)
Industrial differential switches from 80 A and 5SM2 blocks
Product condition, packaging, certifications and applicable manufacturer warranty terms are confirmed with the quotation.
Request a Quote
Pricing and availability are confirmed for each enquiry. Send this part and we will reply with price and lead time.
Request QuoteProduct Overview
An RC unit for 5SL4 is a modular protective accessory designed to safeguard electrical installations against earth leakage faults and indirect contact hazards. This Siemens 5SM2636-8 component integrates with compatible circuit breakers to interrupt power supply whenever residual currents exceed safe operational thresholds, helping prevent equipment damage and electrical fires.
Pricing, availability and lead time are confirmed per enquiry through an RFQ.
- Product Article Number (Market Facing Number): 5SM2636-8
- Product Description: RC unit for 5SL4, 3-pole, type A, selective, In: 63 A, 300 mA, Un AC: 400 V
- Product family: RC Units
- Product Lifecycle (PLM): PM300:Active Product
- Metal Factor: L-A-----
- Delivery information Export Control Regulations: AL : N / ECCN : EAR99
- Standard lead time ex-works: 2 Day/Days
- Net Weight (kg): 0,289 Kg
- Packaging Dimension: 105,00 x 130,00 x 81,00
- Package size unit of measure: MM
- Quantity Unit: 1 Piece
- Packaging Quantity: 1
- Additional Product Information EAN: 4001869461120
- UPC: Not available
- Commodity Code: 85362010
- LKZ_FDB/ CatalogID: LV10.1
More info
▲Technical data
Additional data
| Product | |||||||||||||||||||||||||||||||||||||
| Article Number (Market Facing Number) | 5SM2636-8 | ||||||||||||||||||||||||||||||||||||
| Product Description | RC unit for 5SL4, 3-pole, type A, selective, In: 63 A, 300 mA, Un AC: 400 V | ||||||||||||||||||||||||||||||||||||
| Product family | RC Units | ||||||||||||||||||||||||||||||||||||
| Product Lifecycle (PLM) | PM300:Active Product | ||||||||||||||||||||||||||||||||||||
| Price data | |||||||||||||||||||||||||||||||||||||
| Region Specific PriceGroup / Headquarter Price Group | 11C / 1AH | ||||||||||||||||||||||||||||||||||||
| Surcharge for Raw Materials | None | ||||||||||||||||||||||||||||||||||||
| Metal Factor | L-A----- | ||||||||||||||||||||||||||||||||||||
| Delivery information | |||||||||||||||||||||||||||||||||||||
| Export Control Regulations | AL : N / ECCN : EAR99 | ||||||||||||||||||||||||||||||||||||
| Standard lead time ex-works | 2 Day/Days | ||||||||||||||||||||||||||||||||||||
| Net Weight (kg) | 0,289 Kg | ||||||||||||||||||||||||||||||||||||
| Packaging Dimension | 105,00 x 130,00 x 81,00 | ||||||||||||||||||||||||||||||||||||
| Package size unit of measure | MM | ||||||||||||||||||||||||||||||||||||
| Quantity Unit | 1 Piece | ||||||||||||||||||||||||||||||||||||
| Packaging Quantity | 1 | ||||||||||||||||||||||||||||||||||||
| Additional Product Information | |||||||||||||||||||||||||||||||||||||
| EAN | 4001869461120 | ||||||||||||||||||||||||||||||||||||
| UPC | Not available | ||||||||||||||||||||||||||||||||||||
| Commodity Code | 85362010 | ||||||||||||||||||||||||||||||||||||
| LKZ_FDB/ CatalogID | LV10.1 | ||||||||||||||||||||||||||||||||||||
| Product Group | 5511 | ||||||||||||||||||||||||||||||||||||
| Group Code | P310 | ||||||||||||||||||||||||||||||||||||
| Country of origin | Czech Republic | ||||||||||||||||||||||||||||||||||||
| Compliance with the substance restrictions according to RoHS directive | Since: 01.06.2006 | ||||||||||||||||||||||||||||||||||||
| Product class | B: return restricted, please contact your Siemens partner/contact | ||||||||||||||||||||||||||||||||||||
| WEEE (2012/19/EU) Take-Back Obligation | Yes | ||||||||||||||||||||||||||||||||||||
| REACH Art. 33 Duty to inform according to the current list of candidates |
| ||||||||||||||||||||||||||||||||||||
| Classifications | |||||||||||||||||||||||||||||||||||||
| |||||||||||||||||||||||||||||||||||||
ETIM data
ETIM: EC000003 - Residual current circuit breaker (RCCB)
| Value | Unit | |
|---|---|---|
| Number of poles (EF001391) | 3 | |
| Rated voltage (EF000228) | 400 | V |
| Rated current (EF000227) | 63 | A |
| Rated fault current (EF002358) | 0.3 | mA |
| Rated insulation voltage Ui (EF001366) | 460 | V |
| Rated impulse withstand voltage Uimp (EF011980) | 4.0 | kV |
| Mounting method (EF000003) | DIN rail | |
| Leakage current type (EF002560) | A | |
| Selective protection (EF002561) | true | |
| Short-time delayed tripping (EF003604) | false | |
| Surge current capacity (EF002564) | 5.0 | kA |
| Frequency (EF005455) | 50 Hz | |
| Additional equipment possible (EF008148) | true | |
| With interlocking device (EF007385) | false | |
| Degree of protection (IP) (EF005474) | IP20 | |
| Width in number of modular spacings (EF002950) | 3 | |
| Built-in depth (EF000218) | 70.0 | mm |
| Ambient temperature during operating (EF007515) | ['-25', '45'] | °C |
| Pollution degree (EF002570) | 2 | |
| Connectable conductor cross section multi-wired (EF007343) | ['1.5', '25.0'] | mm² |
| Connectable conductor cross section solid-core (EF007337) | ['1.5', '25.0'] | mm² |
| Short-circuit breaking capacity (Icw) (EF002562) | - | kA |