3WL1012-2AC32-0AA0 SIEMENS withdrawable circuit breakers with guide frame and PSS 3-pole, frame size 0, IEC ..
3WL1012-2AC32-0AA0
10000
SIEMENS
1 Pcs.
Automation > Power circuit-breaker for trafo/generator/installation protection
3WL Air Circuit Breakers
Product condition, packaging, certifications and applicable manufacturer warranty terms are confirmed with the quotation.
Request a Quote
Pricing and availability are confirmed for each enquiry. Send this part and we will reply with price and lead time.
Request QuoteProduct Overview
A Siemens withdrawable circuit breaker offers comprehensive protection and easy rack-out maintenance for high-voltage power distribution setups. These modular breaker units allow safe isolation and replacement within industrial switchgear assemblies without powering down the entire busbar. Pricing, availability and lead time are confirmed per enquiry through an RFQ.
- Product Article Number (Market Facing Number): 3WL1012-2AC32-0AA0
- Product family: Not available
- Product Lifecycle (PLM): PM300:Active Product
- Price data Price Group: 12M
- Metal Factor: LAO-----
- Delivery information Export Control Regulations: ECCN : EAR99 / AL : N
- Standard lead time ex-works: 5 Day/Days
- Net Weight (kg): 40,240 Kg
- Product Dimensions (W x L x H): Not available
- Packaging Dimension: Not available
- Package size unit of measure: Not available
- Quantity Unit: 1 Piece
- Packaging Quantity: 1
- Additional Product Information EAN: Not available
- UPC: Not available
- Commodity Code: 85362090
More info
▲ETIM: EC000228 - Power circuit-breaker for trafo/generator/installation protection
| Value | Unit | |
|---|---|---|
| Number of auxiliary contacts as normally closed contact (EF001377) | - | |
| Position of connection for main current circuit (EF006671) | - | |
| Motor drive integrated (EF006697) | - | |
| DIN rail (top hat rail) mounting optional (EF008904) | - | |
| Rated short-circuit breaking capacity lcu at 400 V, 50 Hz (EF007048) | - | kA |
| Adjustment range short-term delayed short-circuit release (EF007129) | - | A |
| Number of poles (EF001391) | - | |
| Number of auxiliary contacts as normally open contact (EF001376) | - | |
| Rated voltage (EF003977) | - | V |
| Degree of protection (IP) (EF005474) | - | |
| Type of electrical connection of main circuit (EF006819) | - | |
| Adjustment range undelayed short-circuit release (EF007131) | - | A |
| Integrated earth fault protection (EF007296) | - | |
| Motor drive optional (EF007386) | - | |
| With switched-off indicator (EF007006) | - | |
| With under voltage release (EF007518) | - | |
| Number of auxiliary contacts as change-over contact (EF003531) | - | |
| Device construction (EF008240) | - | |
| Suitable for DIN rail (top hat rail) mounting (EF007250) | - | |
| Type of control element (EF006976) | - | |
| Rated permanent current Iu (EF001389) | - | A |
| Complete device with protection unit (EF008906) | - | |
| Overload release current setting (EF002336) | - | A |
| Product | |||||||||||||||||||||||||||||||
| Article Number (Market Facing Number) | 3WL1012-2AC32-0AA0 | ||||||||||||||||||||||||||||||
| Product Description | withdrawable circuit breakers with guide frame and PSS 3-pole, frame size 0, IEC In=1250A to 690V, 50/60Hz AC Icu=55kA at 415V Icu=50kA at 500V Icu=42kA at 690V ETU350 electronic trip units LSI rotary coding switch with tripped signaling switch, rtc and 4Aux auxiliary switches protection adjustable l: Ir 0.4-1 In s: isd 1-10 In; I:ii 1-15 In w. var. n conductor protection rear horizontal connection no communication link, no metering funct. Manual operating mechanism of the spring energy store With mechanical closing Without 2nd auxiliary release Without 1st auxiliary release | ||||||||||||||||||||||||||||||
| Product family | Not available | ||||||||||||||||||||||||||||||
| Product Lifecycle (PLM) | PM300:Active Product | ||||||||||||||||||||||||||||||
| Price data | |||||||||||||||||||||||||||||||
| Price Group | 12M | ||||||||||||||||||||||||||||||
| Surcharge for Raw Materials | None | ||||||||||||||||||||||||||||||
| Metal Factor | LAO----- | ||||||||||||||||||||||||||||||
| Delivery information | |||||||||||||||||||||||||||||||
| Export Control Regulations | ECCN : EAR99 / AL : N | ||||||||||||||||||||||||||||||
| Standard lead time ex-works | 5 Day/Days | ||||||||||||||||||||||||||||||
| Net Weight (kg) | 40,240 Kg | ||||||||||||||||||||||||||||||
| Product Dimensions (W x L x H) | Not available | ||||||||||||||||||||||||||||||
| Packaging Dimension | Not available | ||||||||||||||||||||||||||||||
| Package size unit of measure | Not available | ||||||||||||||||||||||||||||||
| Quantity Unit | 1 Piece | ||||||||||||||||||||||||||||||
| Packaging Quantity | 1 | ||||||||||||||||||||||||||||||
| Additional Product Information | |||||||||||||||||||||||||||||||
| EAN | Not available | ||||||||||||||||||||||||||||||
| UPC | Not available | ||||||||||||||||||||||||||||||
| Commodity Code | 85362090 | ||||||||||||||||||||||||||||||
| LKZ_FDB/ CatalogID | LV10 | ||||||||||||||||||||||||||||||
| Product Group | 3737 | ||||||||||||||||||||||||||||||
| Group Code | P360 | ||||||||||||||||||||||||||||||
| Country of origin | Czech Republic | ||||||||||||||||||||||||||||||
| Compliance with the substance restrictions according to RoHS directive | Given | ||||||||||||||||||||||||||||||
| Product class | C: products manufactured / produced to order, which cannot be reused or re-utilised or be returned against credit. | ||||||||||||||||||||||||||||||
| WEEE (2012/19/EU) Take-Back Obligation | No | ||||||||||||||||||||||||||||||
| REACH Art. 33 Duty to inform according to the current list of candidates |
| ||||||||||||||||||||||||||||||
| Classifications | |||||||||||||||||||||||||||||||
| |||||||||||||||||||||||||||||||