View larger
3WL1008-2AC42-0AA0 SIEMENS withdrawable circuit breakers with guide frame and PSS 4-pole, frame size 0, IEC ..
3WL1008-2AC42-0AA0
10000
SIEMENS
1 Pcs.
Automation > Power circuit-breaker for trafo/generator/installation protection
3WL Air Circuit Breakers
Product condition, packaging, certifications and applicable manufacturer warranty terms are confirmed with the quotation.
Request a Quote
Pricing and availability are confirmed for each enquiry. Send this part and we will reply with price and lead time.
Request QuoteProduct Overview
A Siemens 3WL1008-2AC42-0AA0 withdrawable circuit breaker with guide frame and PSS 4-pole is engineered to protect heavy-duty electrical distribution networks from overload and short-circuit faults. Air circuit breakers like this are commonly deployed in commercial and industrial switchgear assemblies to safely interrupt high fault currents and provide reliable system isolation.
Pricing, availability and lead time are confirmed per enquiry through an RFQ.
- Product Article Number (Market Facing Number): 3WL1008-2AC42-0AA0
- Product family: Not available
- Product Lifecycle (PLM): PM300:Active Product
- Price data Price Group: 12M
- Metal Factor: LAO-----
- Delivery information Export Control Regulations: ECCN : EAR99 / AL : N
- Standard lead time ex-works: 5 Day/Days
- Net Weight (kg): 46,840 Kg
- Product Dimensions (W x L x H): Not available
- Packaging Dimension: Not available
- Package size unit of measure: Not available
- Quantity Unit: 1 Piece
- Packaging Quantity: 1
- Additional Product Information EAN: Not available
- UPC: Not available
- Commodity Code: 85362090
More info
▲ETIM: EC000228 - Power circuit-breaker for trafo/generator/installation protection
| Value | Unit | |
|---|---|---|
| Motor drive optional (EF007386) | - | |
| Suitable for DIN rail (top hat rail) mounting (EF007250) | - | |
| Rated voltage (EF003977) | - | V |
| Type of electrical connection of main circuit (EF006819) | - | |
| Number of auxiliary contacts as normally open contact (EF001376) | - | |
| Motor drive integrated (EF006697) | - | |
| Rated short-circuit breaking capacity lcu at 400 V, 50 Hz (EF007048) | - | kA |
| Adjustment range short-term delayed short-circuit release (EF007129) | - | A |
| Adjustment range undelayed short-circuit release (EF007131) | - | A |
| Complete device with protection unit (EF008906) | - | |
| Rated permanent current Iu (EF001389) | - | A |
| Number of auxiliary contacts as change-over contact (EF003531) | - | |
| Type of control element (EF006976) | - | |
| With switched-off indicator (EF007006) | - | |
| Integrated earth fault protection (EF007296) | - | |
| With under voltage release (EF007518) | - | |
| Device construction (EF008240) | - | |
| Number of auxiliary contacts as normally closed contact (EF001377) | - | |
| Overload release current setting (EF002336) | - | A |
| DIN rail (top hat rail) mounting optional (EF008904) | - | |
| Position of connection for main current circuit (EF006671) | - | |
| Degree of protection (IP) (EF005474) | - | |
| Number of poles (EF001391) | - |
| Product | |||||||||||||||||||||||||||||||
| Article Number (Market Facing Number) | 3WL1008-2AC42-0AA0 | ||||||||||||||||||||||||||||||
| Product Description | withdrawable circuit breakers with guide frame and PSS 4-pole, frame size 0, IEC N conductor on the left In=800A to 690V, 50/60Hz AC Icu=55kA at 415V Icu=50kA at 500V Icu=42kA at 690V ETU350 electronic trip units LSI rotary coding switch with tripped signaling switch, RTC and 4Aux auxiliary switches protection adjustable l: Ir 0.4-1 In s: isd 1-10 In; I:ii 1-15 In w. var. n conductor protection rear horizontal connection no communication link, no metering funct. Manual operating mechanism of the spring energy store With mechanical closing Without 2nd auxiliary release Without 1st auxiliary release | ||||||||||||||||||||||||||||||
| Product family | Not available | ||||||||||||||||||||||||||||||
| Product Lifecycle (PLM) | PM300:Active Product | ||||||||||||||||||||||||||||||
| Price data | |||||||||||||||||||||||||||||||
| Price Group | 12M | ||||||||||||||||||||||||||||||
| Surcharge for Raw Materials | None | ||||||||||||||||||||||||||||||
| Metal Factor | LAO----- | ||||||||||||||||||||||||||||||
| Delivery information | |||||||||||||||||||||||||||||||
| Export Control Regulations | ECCN : EAR99 / AL : N | ||||||||||||||||||||||||||||||
| Standard lead time ex-works | 5 Day/Days | ||||||||||||||||||||||||||||||
| Net Weight (kg) | 46,840 Kg | ||||||||||||||||||||||||||||||
| Product Dimensions (W x L x H) | Not available | ||||||||||||||||||||||||||||||
| Packaging Dimension | Not available | ||||||||||||||||||||||||||||||
| Package size unit of measure | Not available | ||||||||||||||||||||||||||||||
| Quantity Unit | 1 Piece | ||||||||||||||||||||||||||||||
| Packaging Quantity | 1 | ||||||||||||||||||||||||||||||
| Additional Product Information | |||||||||||||||||||||||||||||||
| EAN | Not available | ||||||||||||||||||||||||||||||
| UPC | Not available | ||||||||||||||||||||||||||||||
| Commodity Code | 85362090 | ||||||||||||||||||||||||||||||
| LKZ_FDB/ CatalogID | LV10 | ||||||||||||||||||||||||||||||
| Product Group | 3737 | ||||||||||||||||||||||||||||||
| Group Code | P360 | ||||||||||||||||||||||||||||||
| Country of origin | Czech Republic | ||||||||||||||||||||||||||||||
| Compliance with the substance restrictions according to RoHS directive | Given | ||||||||||||||||||||||||||||||
| Product class | C: products manufactured / produced to order, which cannot be reused or re-utilised or be returned against credit. | ||||||||||||||||||||||||||||||
| WEEE (2012/19/EU) Take-Back Obligation | No | ||||||||||||||||||||||||||||||
| REACH Art. 33 Duty to inform according to the current list of candidates |
| ||||||||||||||||||||||||||||||
| Classifications | |||||||||||||||||||||||||||||||
| |||||||||||||||||||||||||||||||