View larger
3VA6110-7JP31-0AA0 SIEMENS circuit breaker 3VA6 UL frame 150 breaking capacity class C 100kA @ 480V 3-pole, ..
3VA6110-7JP31-0AA0
10000
SIEMENS
1 Pcs.
Automation > Power circuit-breaker for trafo/generator/installation protection
Moulded Case Circuit Breakers 3VA SENTRON
Product condition, packaging, certifications and applicable manufacturer warranty terms are confirmed with the quotation.
Request a Quote
Pricing and availability are confirmed for each enquiry. Send this part and we will reply with price and lead time.
Request QuoteProduct Overview
Engineered for reliable distribution duties, this Siemens 3VA6110-7JP31-0AA0 circuit breaker safeguards industrial electrical networks against overloads and short circuits. Molded-case circuit breakers like this unit interrupt fault currents to prevent catastrophic damage to downstream machinery and personnel.
Pricing, availability and lead time are confirmed per enquiry through an RFQ.
- product designation: Molded-case circuit breaker
- product designation / according to UL file: CDAE
- Product version: System protection
- design of the overcurrent release: ETU550
- protection function of the overcurrent release: LSI
- number of poles: 3
- General technical data rated insulation voltage Ui: 800 V
- power loss [W] / maximum: 13 W
- mechanical service life (switching cycles) / typical: 25 000
- electrical endurance (switching cycles) / at 480 V: 14 000
- electrical endurance (switching cycles) / at 600 V: 9 800
- Neutral conductors / upgradeable/retrofittable: Yes
- ground-fault monitoring version: Without
- ● communication function: Yes
- ● other measurement function: No
- Net Weight: 2.5 kg
More info
▲Technical data
Additional data
| Product | |||||||||||||||||||||||||||||||||||||
| Article Number (Market Facing Number) | 3VA6110-7JP31-0AA0 | ||||||||||||||||||||||||||||||||||||
| Product Description | circuit breaker 3VA6 UL frame 150 breaking capacity class C 100kA @ 480V 3-pole, line protection ETU550, LSI, In=100A overload protection Ir=40A...100A short-circuit protection Isd=0.6..10x In, Ii=1.5..12x In N conductor protection optionally with external current transformer, up to 160% without connection | ||||||||||||||||||||||||||||||||||||
| Product family | 3VA Molded Case Circuit Breakers up to 1000 A, UL / IEC | ||||||||||||||||||||||||||||||||||||
| Product Lifecycle (PLM) | PM300:Active Product | ||||||||||||||||||||||||||||||||||||
| Price data | |||||||||||||||||||||||||||||||||||||
| Region Specific PriceGroup / Headquarter Price Group | 12P / 1CB | ||||||||||||||||||||||||||||||||||||
| Surcharge for Raw Materials | None | ||||||||||||||||||||||||||||||||||||
| Metal Factor | LOA----- | ||||||||||||||||||||||||||||||||||||
| Delivery information | |||||||||||||||||||||||||||||||||||||
| Export Control Regulations | AL : N / ECCN : EAR99 | ||||||||||||||||||||||||||||||||||||
| Standard lead time ex-works | 15 Day/Days | ||||||||||||||||||||||||||||||||||||
| Net Weight (kg) | 2,500 Kg | ||||||||||||||||||||||||||||||||||||
| Packaging Dimension | 134,00 x 200,00 x 145,00 | ||||||||||||||||||||||||||||||||||||
| Package size unit of measure | MM | ||||||||||||||||||||||||||||||||||||
| Quantity Unit | 1 Piece | ||||||||||||||||||||||||||||||||||||
| Packaging Quantity | 1 | ||||||||||||||||||||||||||||||||||||
| Additional Product Information | |||||||||||||||||||||||||||||||||||||
| EAN | 4042948850817 | ||||||||||||||||||||||||||||||||||||
| UPC | 804766306310 | ||||||||||||||||||||||||||||||||||||
| Commodity Code | 85362090 | ||||||||||||||||||||||||||||||||||||
| LKZ_FDB/ CatalogID | LV10 | ||||||||||||||||||||||||||||||||||||
| Product Group | 5383 | ||||||||||||||||||||||||||||||||||||
| Group Code | P360 | ||||||||||||||||||||||||||||||||||||
| Country of origin | Czech Republic | ||||||||||||||||||||||||||||||||||||
| Compliance with the substance restrictions according to RoHS directive | Since: 01.01.2016 | ||||||||||||||||||||||||||||||||||||
| Product class | C: products manufactured / produced to order, which cannot be reused or re-utilised or be returned against credit. | ||||||||||||||||||||||||||||||||||||
| WEEE (2012/19/EU) Take-Back Obligation | Yes | ||||||||||||||||||||||||||||||||||||
| REACH Art. 33 Duty to inform according to the current list of candidates |
| ||||||||||||||||||||||||||||||||||||
| Classifications | |||||||||||||||||||||||||||||||||||||
| |||||||||||||||||||||||||||||||||||||
ETIM data
ETIM: EC000228 - Power circuit-breaker for trafo/generator/installation protection
| Value | Unit | |
|---|---|---|
| Rated permanent current Iu (EF001389) | 100.0 | A |
| Rated voltage (EF003977) | ['600', '600'] | V |
| Rated short-circuit breaking capacity lcu at 400 V, 50 Hz (EF007048) | 110.0 | kA |
| Overload release current setting (EF002336) | ['-', '-'] | A |
| Adjustment range short-term delayed short-circuit release (EF007129) | ['-', '-'] | A |
| Adjustment range undelayed short-circuit release (EF007131) | ['-', '-'] | A |
| Integrated earth fault protection (EF007296) | false | |
| Type of electrical connection of main circuit (EF006819) | Other | |
| Device construction (EF008240) | Built-in device fixed built-in technique | |
| Suitable for DIN rail (top hat rail) mounting (EF007250) | true | |
| DIN rail (top hat rail) mounting optional (EF008904) | true | |
| Number of auxiliary contacts as normally closed contact (EF001377) | 0 | |
| Number of auxiliary contacts as normally open contact (EF001376) | 0 | |
| Number of auxiliary contacts as change-over contact (EF003531) | 0 | |
| With switched-off indicator (EF007006) | - | |
| With under voltage release (EF007518) | - | |
| Number of poles (EF001391) | 3 | |
| Position of connection for main current circuit (EF006671) | Other | |
| Type of control element (EF006976) | Rocker lever | |
| Complete device with protection unit (EF008906) | true | |
| Motor drive integrated (EF006697) | false | |
| Motor drive optional (EF007386) | true | |
| Degree of protection (IP) (EF005474) | IP40 |













