View larger
3VA5212-6ED31-0AA0 SIEMENS circuit breaker 3VA5 UL frame 250 breaking capacity class H 65kA @ 480V 3-pole, l..
3VA5212-6ED31-0AA0
10000
SIEMENS
1 Pcs.
Automation > Power circuit-breaker for trafo/generator/installation protection
Moulded Case Circuit Breakers 3VA SENTRON
Product condition, packaging, certifications and applicable manufacturer warranty terms are confirmed with the quotation.
Request a Quote
Pricing and availability are confirmed for each enquiry. Send this part and we will reply with price and lead time.
Request QuoteProduct Overview
Siemens 3VA5212-6ED31-0AA0 circuit breaker is a molded-case protective unit designed for reliable branch circuit protection in industrial control systems. Such circuit-breakers automatically disconnect power during overload and short-circuit conditions to maintain operational safety.
Pricing, availability and lead time are confirmed per enquiry through an RFQ.
- product designation: Molded-case circuit breaker
- product designation / according to UL file: HFAS
- Product version: System protection
- design of the overcurrent release: TM210
- protection function of the overcurrent release: LI
- number of poles: 3
- General technical data rated insulation voltage Ui: 800 V
- Max. rated operational voltage Ue with DC: 750 V
- power loss [W] / maximum: 23 W
- mechanical service life (switching cycles) / typical: 20 000
- electrical endurance (switching cycles) / at 480 V: 8 000
- electrical endurance (switching cycles) / at 600 V: 4 000
- Neutral conductors / upgradeable/retrofittable: No
- ● communication function: No
- ● other measurement function: No
- Net Weight: 2 kg
More info
▲Technical data
Additional data
| Product | |||||||||||||||||||||||||||||||||||||
| Article Number (Market Facing Number) | 3VA5212-6ED31-0AA0 | ||||||||||||||||||||||||||||||||||||
| Product Description | circuit breaker 3VA5 UL frame 250 breaking capacity class H 65kA @ 480V 3-pole, line protection TM210, FTFM, In=125A overload protection Ir=125A fixed short-circuit protection Ii=10 x In without connection | ||||||||||||||||||||||||||||||||||||
| Product family | 3VA Molded Case Circuit Breakers up to 1000 A, UL / IEC | ||||||||||||||||||||||||||||||||||||
| Product Lifecycle (PLM) | PM300:Active Product | ||||||||||||||||||||||||||||||||||||
| Price data | |||||||||||||||||||||||||||||||||||||
| Region Specific PriceGroup / Headquarter Price Group | 12P / 1CB | ||||||||||||||||||||||||||||||||||||
| Surcharge for Raw Materials | None | ||||||||||||||||||||||||||||||||||||
| Metal Factor | LOA----- | ||||||||||||||||||||||||||||||||||||
| Delivery information | |||||||||||||||||||||||||||||||||||||
| Export Control Regulations | AL : N / ECCN : EAR99 | ||||||||||||||||||||||||||||||||||||
| Standard lead time ex-works | 40 Day/Days | ||||||||||||||||||||||||||||||||||||
| Net Weight (kg) | 2,000 Kg | ||||||||||||||||||||||||||||||||||||
| Packaging Dimension | 150,00 x 245,00 x 160,00 | ||||||||||||||||||||||||||||||||||||
| Package size unit of measure | MM | ||||||||||||||||||||||||||||||||||||
| Quantity Unit | 1 Piece | ||||||||||||||||||||||||||||||||||||
| Packaging Quantity | 1 | ||||||||||||||||||||||||||||||||||||
| Additional Product Information | |||||||||||||||||||||||||||||||||||||
| EAN | 4042948854365 | ||||||||||||||||||||||||||||||||||||
| UPC | 804766308543 | ||||||||||||||||||||||||||||||||||||
| Commodity Code | 85362090 | ||||||||||||||||||||||||||||||||||||
| LKZ_FDB/ CatalogID | LV10 | ||||||||||||||||||||||||||||||||||||
| Product Group | 5385 | ||||||||||||||||||||||||||||||||||||
| Group Code | P360 | ||||||||||||||||||||||||||||||||||||
| Country of origin | Czech Republic | ||||||||||||||||||||||||||||||||||||
| Compliance with the substance restrictions according to RoHS directive | Since: 01.01.2016 | ||||||||||||||||||||||||||||||||||||
| Product class | C: products manufactured / produced to order, which cannot be reused or re-utilised or be returned against credit. | ||||||||||||||||||||||||||||||||||||
| WEEE (2012/19/EU) Take-Back Obligation | Yes | ||||||||||||||||||||||||||||||||||||
| REACH Art. 33 Duty to inform according to the current list of candidates |
| ||||||||||||||||||||||||||||||||||||
| Classifications | |||||||||||||||||||||||||||||||||||||
| |||||||||||||||||||||||||||||||||||||
ETIM data
ETIM: EC000228 - Power circuit-breaker for trafo/generator/installation protection
| Value | Unit | |
|---|---|---|
| Rated permanent current Iu (EF001389) | 125.0 | A |
| Rated voltage (EF003977) | ['690', '690'] | V |
| Rated short-circuit breaking capacity lcu at 400 V, 50 Hz (EF007048) | 70.0 | kA |
| Overload release current setting (EF002336) | ['-', '-'] | A |
| Adjustment range short-term delayed short-circuit release (EF007129) | ['-', '-'] | A |
| Adjustment range undelayed short-circuit release (EF007131) | ['-', '-'] | A |
| Integrated earth fault protection (EF007296) | false | |
| Type of electrical connection of main circuit (EF006819) | Other | |
| Device construction (EF008240) | Built-in device fixed built-in technique | |
| Suitable for DIN rail (top hat rail) mounting (EF007250) | true | |
| DIN rail (top hat rail) mounting optional (EF008904) | true | |
| Number of auxiliary contacts as normally closed contact (EF001377) | 0 | |
| Number of auxiliary contacts as normally open contact (EF001376) | 0 | |
| Number of auxiliary contacts as change-over contact (EF003531) | 0 | |
| With switched-off indicator (EF007006) | - | |
| With under voltage release (EF007518) | - | |
| Number of poles (EF001391) | 3 | |
| Position of connection for main current circuit (EF006671) | Other | |
| Type of control element (EF006976) | Rocker lever | |
| Complete device with protection unit (EF008906) | true | |
| Motor drive integrated (EF006697) | false | |
| Motor drive optional (EF007386) | true | |
| Degree of protection (IP) (EF005474) | IP40 |