View larger
3VA1125-6GF46-0AA0 SIEMENS circuit breaker 3VA1 IEC frame 160 breaking capacity class H Icu 70kA @ 415V 4-po..
3VA1125-6GF46-0AA0
11256
SIEMENS
1 Pcs.
Automation > Power circuit-breaker for trafo/generator/installation protection
Moulded Case Circuit Breakers 3VA SENTRON
Product condition, packaging, certifications and applicable manufacturer warranty terms are confirmed with the quotation.
Request a Quote
Pricing and availability are confirmed for each enquiry. Send this part and we will reply with price and lead time.
Request QuoteProduct Overview
Electrical installations requiring dependable line protection often utilize the 3VA1125-6GF46-0AA0 Siemens circuit breaker to isolate faults and protect distribution wiring. Molded case breakers are installed within control cabinets to prevent thermal overloads and safely disconnect power when anomalies occur. Pricing, availability and lead time are confirmed per enquiry through an RFQ.
- product designation: Molded case circuit breaker
- Product version: Line protection
- design of the overcurrent release: TM240
- protection function of the overcurrent release: LI
- number of poles: 4
- General technical data rated insulation voltage Ui: 800 V
- Max. rated operational voltage Ue with DC: 600 V
- power loss [W] / maximum: 8.5 W
- mechanical service life (switching cycles) / typical: 20 000
- Neutral conductors / upgradeable/retrofittable: No
- ground-fault monitoring version: Without
- ● communication function: No
- ● other measurement function: No
- Net Weight: 1.337 kg
- Current Max. rated operational current of the frame size: 160 A
- Courant permanent assigné Iu: 25 A
More info
▲Technical data
Additional data
| Product | |||||||||||||||||||||||||||||||||||||
| Article Number (Market Facing Number) | 3VA1125-6GF46-0AA0 | ||||||||||||||||||||||||||||||||||||
| Product Description | circuit breaker 3VA1 IEC frame 160 breaking capacity class H Icu=70kA @ 415V 4-pole, line protection TM240, ATAM, In=25A overload protection Ir=18A...25A short-circuit protection Ii=6.4...12.8 x In N conductor protection 100% clamp connection | ||||||||||||||||||||||||||||||||||||
| Product family | 3VA Molded Case Circuit Breakers up to 1600 A, IEC | ||||||||||||||||||||||||||||||||||||
| Product Lifecycle (PLM) | PM300:Active Product | ||||||||||||||||||||||||||||||||||||
| Price data | |||||||||||||||||||||||||||||||||||||
| Region Specific PriceGroup / Headquarter Price Group | 12P / 1CB | ||||||||||||||||||||||||||||||||||||
| Surcharge for Raw Materials | None | ||||||||||||||||||||||||||||||||||||
| Metal Factor | LOA----- | ||||||||||||||||||||||||||||||||||||
| Delivery information | |||||||||||||||||||||||||||||||||||||
| Export Control Regulations | AL : N / ECCN : EAR99 | ||||||||||||||||||||||||||||||||||||
| Standard lead time ex-works | 5 Day/Days | ||||||||||||||||||||||||||||||||||||
| Net Weight (kg) | 1,337 Kg | ||||||||||||||||||||||||||||||||||||
| Packaging Dimension | 119,00 x 150,00 x 116,00 | ||||||||||||||||||||||||||||||||||||
| Package size unit of measure | MM | ||||||||||||||||||||||||||||||||||||
| Quantity Unit | 1 Piece | ||||||||||||||||||||||||||||||||||||
| Packaging Quantity | 1 | ||||||||||||||||||||||||||||||||||||
| Additional Product Information | |||||||||||||||||||||||||||||||||||||
| EAN | 4042948824351 | ||||||||||||||||||||||||||||||||||||
| UPC | 804766426209 | ||||||||||||||||||||||||||||||||||||
| Commodity Code | 85362010 | ||||||||||||||||||||||||||||||||||||
| LKZ_FDB/ CatalogID | LV10.1 | ||||||||||||||||||||||||||||||||||||
| Product Group | 5375 | ||||||||||||||||||||||||||||||||||||
| Group Code | P360 | ||||||||||||||||||||||||||||||||||||
| Country of origin | Czech Republic | ||||||||||||||||||||||||||||||||||||
| Compliance with the substance restrictions according to RoHS directive | Since: 01.04.2014 | ||||||||||||||||||||||||||||||||||||
| Product class | C: products manufactured / produced to order, which cannot be reused or re-utilised or be returned against credit. | ||||||||||||||||||||||||||||||||||||
| WEEE (2012/19/EU) Take-Back Obligation | Yes | ||||||||||||||||||||||||||||||||||||
| REACH Art. 33 Duty to inform according to the current list of candidates |
| ||||||||||||||||||||||||||||||||||||
| Classifications | |||||||||||||||||||||||||||||||||||||
| |||||||||||||||||||||||||||||||||||||
ETIM data
ETIM: EC000228 - Power circuit-breaker for trafo/generator/installation protection
| Value | Unit | |
|---|---|---|
| Rated permanent current Iu (EF001389) | 25.0 | A |
| Rated voltage (EF003977) | ['690', '690'] | V |
| Rated short-circuit breaking capacity lcu at 400 V, 50 Hz (EF007048) | 70.0 | kA |
| Overload release current setting (EF002336) | ['18', '25'] | A |
| Adjustment range short-term delayed short-circuit release (EF007129) | ['-', '-'] | A |
| Adjustment range undelayed short-circuit release (EF007131) | ['160', '320'] | A |
| Integrated earth fault protection (EF007296) | false | |
| Type of electrical connection of main circuit (EF006819) | Frame clamp | |
| Device construction (EF008240) | Built-in device fixed built-in technique | |
| Suitable for DIN rail (top hat rail) mounting (EF007250) | true | |
| DIN rail (top hat rail) mounting optional (EF008904) | true | |
| Number of auxiliary contacts as normally closed contact (EF001377) | 0 | |
| Number of auxiliary contacts as normally open contact (EF001376) | 0 | |
| Number of auxiliary contacts as change-over contact (EF003531) | 0 | |
| With switched-off indicator (EF007006) | - | |
| With under voltage release (EF007518) | - | |
| Number of poles (EF001391) | 4 | |
| Position of connection for main current circuit (EF006671) | Front side | |
| Type of control element (EF006976) | Rocker lever | |
| Complete device with protection unit (EF008906) | true | |
| Motor drive integrated (EF006697) | false | |
| Motor drive optional (EF007386) | true | |
| Degree of protection (IP) (EF005474) | IP40 |