View larger
3UG4832-2AA40 SIEMENS Digital monitoring relay Voltage monitoring, 22.5 mm for IO-Link 10...600 V AC/DC Over..
3UG4832-2AA40
48322
SIEMENS
1 Pcs.
Automation > Voltage monitoring relay
Function relays
Product condition, packaging, certifications and applicable manufacturer warranty terms are confirmed with the quotation.
Request a Quote
Pricing and availability are confirmed for each enquiry. Send this part and we will reply with price and lead time.
Request QuoteProduct Overview
The Siemens 3UG4832-2AA40 is a digital monitoring relay designed to continuously check voltage levels in industrial control panels and protect sensitive equipment from abnormal operating conditions. Voltage monitoring relays are widely used across electrical distribution systems to trigger protective shutdowns or alarms whenever supply parameters drift outside predefined safe thresholds.
Pricing, availability, and lead time are confirmed per enquiry through an RFQ.
- product designation: Voltage monitoring relay with digital setting
- product type designation: 3UG4
- General technical data product function: Voltage monitoring relay
- design of the display: LCD
- ● with degree of pollution 2 rated value: 690 V
- degree of pollution: 2
- ● for monitoring: AC/DC
- ● of the control supply voltage: DC
- surge voltage resistance rated value: 6 kV
- ● between control and auxiliary circuit: 690 V
- protection class IP: IP20
- shock resistance according to IEC 60068-2-27: sinusoidal half-wave 15g / 11 ms
- vibration resistance according to IEC 60068-2-6: 1 ... 6 Hz: 15 mm, 6 ... 500 Hz: 2g
- mechanical service life (switching cycles) typical: 10 000 002
- reference code according to IEC 81346-2: K
- relative repeat accuracy: 1 %
More info
▲Technical data
Additional data
| Product | ||||||||||||||||||||||||||||||||||||||||
| Article Number (Market Facing Number) | 3UG4832-2AA40 | |||||||||||||||||||||||||||||||||||||||
| Product Description | Digital monitoring relay Voltage monitoring, 22.5 mm for IO-Link 10...600 V AC/DC Overvoltage and undervoltage Hysteresis 0.1 to 300 V ON-delay time Tripping delay time 1 change-over contact, spring-type connection system | |||||||||||||||||||||||||||||||||||||||
| Product family | Voltage monitoring | |||||||||||||||||||||||||||||||||||||||
| Product Lifecycle (PLM) | PM300:Active Product | |||||||||||||||||||||||||||||||||||||||
| Price data | ||||||||||||||||||||||||||||||||||||||||
| Region Specific PriceGroup / Headquarter Price Group | 41H / 41H | |||||||||||||||||||||||||||||||||||||||
| Surcharge for Raw Materials | None | |||||||||||||||||||||||||||||||||||||||
| Metal Factor | LAO----- | |||||||||||||||||||||||||||||||||||||||
| Delivery information | ||||||||||||||||||||||||||||||||||||||||
| Export Control Regulations | AL : N / ECCN : N | |||||||||||||||||||||||||||||||||||||||
| Standard lead time ex-works | 2 Day/Days | |||||||||||||||||||||||||||||||||||||||
| Net Weight (kg) | 0,147 Kg | |||||||||||||||||||||||||||||||||||||||
| Packaging Dimension | 34,00 x 99,00 x 111,00 | |||||||||||||||||||||||||||||||||||||||
| Package size unit of measure | MM | |||||||||||||||||||||||||||||||||||||||
| Quantity Unit | 1 Piece | |||||||||||||||||||||||||||||||||||||||
| Packaging Quantity | 1 | |||||||||||||||||||||||||||||||||||||||
| Additional Product Information | ||||||||||||||||||||||||||||||||||||||||
| EAN | 4011209895867 | |||||||||||||||||||||||||||||||||||||||
| UPC | 040892871838 | |||||||||||||||||||||||||||||||||||||||
| Commodity Code | 85364900 | |||||||||||||||||||||||||||||||||||||||
| LKZ_FDB/ CatalogID | CC-IC10 | |||||||||||||||||||||||||||||||||||||||
| Product Group | 5885 | |||||||||||||||||||||||||||||||||||||||
| Group Code | R711 | |||||||||||||||||||||||||||||||||||||||
| Country of origin | Czech Republic | |||||||||||||||||||||||||||||||||||||||
| Compliance with the substance restrictions according to RoHS directive | Since: 01.05.2012 | |||||||||||||||||||||||||||||||||||||||
| Product class | A: Standard product which is a stock item could be returned within the returns guidelines/period. | |||||||||||||||||||||||||||||||||||||||
| WEEE (2012/19/EU) Take-Back Obligation | Yes | |||||||||||||||||||||||||||||||||||||||
| REACH Art. 33 Duty to inform according to the current list of candidates |
| |||||||||||||||||||||||||||||||||||||||
| Classifications | ||||||||||||||||||||||||||||||||||||||||
| ||||||||||||||||||||||||||||||||||||||||
ETIM data
ETIM: EC001438 - Voltage monitoring relay
| Value | Unit | |
|---|---|---|
| Type of electric connection (EF003961) | Spring clamp connection | |
| With detachable clamps (EF003340) | true | |
| Single-phase under voltage possible (EF003390) | true | |
| Three-phase under voltage possible (EF003391) | false | |
| Single-phase over voltage possible (EF003392) | true | |
| Three-phase over voltage possible (EF003393) | false | |
| Single-phase hysteresis possible (EF003394) | true | |
| Three-phase hysteresis possible (EF003395) | false | |
| Contains function DC-under voltage (EF003396) | true | |
| Contains function DC-over voltage (EF003397) | true | |
| Contains function DC-voltage hysteresis (EF003398) | true | |
| Voltage measurement range 1 (EF006134) | ['10', '600'] | V |
| Voltage measurement range 2 (EF006135) | ['-', '-'] | V |
| Type of voltage measurement range (EF003399) | AC/DC | |
| Rated control supply voltage Us at DC (EF003980) | ['18', '30'] | V |
| Voltage type for actuating (EF008242) | DC | |
| Response value voltage (EF008193) | ['10', '600'] | V |
| Min. adjustable delay-on energization time (EF008190) | 0 | s |
| Max. permitted delay-on energization time (EF008189) | 999.9 | s |
| Min. adjustable off-delay time (EF008192) | 0 | s |
| Max. permitted off-delay time (EF008191) | 999.9 | s |
| Number of contacts as normally closed contact (EF008255) | 0 | |
| Number of contacts as normally open contact (EF008256) | 0 | |
| Number of contacts as change-over contact (EF008257) | 1 | |
| Width (EF000008) | 22.5 | mm |
| Height (EF000040) | 94.0 | mm |
| Depth (EF000049) | 91.0 | mm |
| Rated control supply voltage Us at AC 50HZ (EF003978) | - | V |
| Rated control supply voltage Us at AC 60HZ (EF003979) | - | V |