View larger
3UG4822-1AA40 SIEMENS Digital monitoring relay Current monitoring, 22.5 mm for IO-Link 0.05...10.0 A AC/DC O..
3UG4822-1AA40
48221
SIEMENS
1 Pcs.
Automation > Current monitoring relay
Function relays
Product condition, packaging, certifications and applicable manufacturer warranty terms are confirmed with the quotation.
Request a Quote
Pricing and availability are confirmed for each enquiry. Send this part and we will reply with price and lead time.
Request QuoteProduct Overview
Digital monitoring relay current monitoring provides precise observation of electrical parameters in industrial installations, helping prevent unscheduled downtime by detecting out-of-range operating conditions. These relays are commonly integrated into motor control centers and automated power distribution networks to supervise critical thresholds. Pricing, availability and lead time are confirmed per enquiry through an RFQ.
- product designation: Current monitoring relay with digital setting
- product type designation: 3UG4
- General technical data product function: Current monitoring relay
- design of the display: LCD
- ● with degree of pollution 2 rated value: 690 V
- degree of pollution: 2
- surge voltage resistance rated value: 6 kV
- ● between control and auxiliary circuit: 690 V
- protection class IP: IP20
- shock resistance according to IEC 60068-2-27: sinusoidal half-wave 15g / 11 ms
- vibration resistance according to IEC 60068-2-6: 1 ... 6 Hz: 15 mm, 6 ... 500 Hz: 2g
- mechanical service life (switching cycles) typical: 10 000 001
- reference code according to IEC 81346-2: K
- relative repeat accuracy: 1 %
- Substance Prohibitance (Date): 05/01/2012
- ● overcurrent detection 1 phase: Yes
More info
▲Technical data
Additional data
| Product | ||||||||||||||||||||||||||||||||||||||||
| Article Number (Market Facing Number) | 3UG4822-1AA40 | |||||||||||||||||||||||||||||||||||||||
| Product Description | Digital monitoring relay Current monitoring, 22.5 mm for IO-Link 0.05...10.0 A AC/DC Overcurrent and undercurrent Transformer scaling factor Hysteresis 0.01 to 5.0 A ON-delay time Tripping delay time 1 change-over contact, screw terminal | |||||||||||||||||||||||||||||||||||||||
| Product family | Current monitoring | |||||||||||||||||||||||||||||||||||||||
| Product Lifecycle (PLM) | PM300:Active Product | |||||||||||||||||||||||||||||||||||||||
| Price data | ||||||||||||||||||||||||||||||||||||||||
| Region Specific PriceGroup / Headquarter Price Group | 41H / 41H | |||||||||||||||||||||||||||||||||||||||
| Surcharge for Raw Materials | None | |||||||||||||||||||||||||||||||||||||||
| Metal Factor | LAO----- | |||||||||||||||||||||||||||||||||||||||
| Delivery information | ||||||||||||||||||||||||||||||||||||||||
| Export Control Regulations | AL : N / ECCN : N | |||||||||||||||||||||||||||||||||||||||
| Standard lead time ex-works | 2 Day/Days | |||||||||||||||||||||||||||||||||||||||
| Net Weight (kg) | 0,147 Kg | |||||||||||||||||||||||||||||||||||||||
| Packaging Dimension | 37,00 x 100,00 x 111,00 | |||||||||||||||||||||||||||||||||||||||
| Package size unit of measure | MM | |||||||||||||||||||||||||||||||||||||||
| Quantity Unit | 1 Piece | |||||||||||||||||||||||||||||||||||||||
| Packaging Quantity | 1 | |||||||||||||||||||||||||||||||||||||||
| Additional Product Information | ||||||||||||||||||||||||||||||||||||||||
| EAN | 4011209895805 | |||||||||||||||||||||||||||||||||||||||
| UPC | 040892871807 | |||||||||||||||||||||||||||||||||||||||
| Commodity Code | 85364900 | |||||||||||||||||||||||||||||||||||||||
| LKZ_FDB/ CatalogID | CC-IC10 | |||||||||||||||||||||||||||||||||||||||
| Product Group | 5885 | |||||||||||||||||||||||||||||||||||||||
| Group Code | R711 | |||||||||||||||||||||||||||||||||||||||
| Country of origin | Czech Republic | |||||||||||||||||||||||||||||||||||||||
| Compliance with the substance restrictions according to RoHS directive | Since: 01.05.2012 | |||||||||||||||||||||||||||||||||||||||
| Product class | A: Standard product which is a stock item could be returned within the returns guidelines/period. | |||||||||||||||||||||||||||||||||||||||
| WEEE (2012/19/EU) Take-Back Obligation | Yes | |||||||||||||||||||||||||||||||||||||||
| REACH Art. 33 Duty to inform according to the current list of candidates |
| |||||||||||||||||||||||||||||||||||||||
| Classifications | ||||||||||||||||||||||||||||||||||||||||
| ||||||||||||||||||||||||||||||||||||||||
ETIM data
ETIM: EC001440 - Current monitoring relay
| Value | Unit | |
|---|---|---|
| External current transformer (EF001923) | - | |
| Type of electric connection (EF003961) | Screw connection | |
| With detachable clamps (EF003340) | true | |
| Single-phase under current possible (EF003405) | true | |
| Three-phase under current possible (EF003406) | false | |
| Single-phase over current possible (EF003407) | true | |
| Three-phase over current possible (EF003408) | false | |
| Single-phase hysteresis possible (EF003394) | false | |
| Three-phase hysteresis possible (EF003395) | false | |
| Contains function DC-voltage under current (EF003409) | true | |
| Contains function DC-voltage over current (EF003410) | true | |
| Function DC-current hysteresis (EF003411) | true | |
| Rated control supply voltage Us at AC 50HZ (EF003978) | ['-', '-'] | V |
| Rated control supply voltage Us at AC 60HZ (EF003979) | ['-', '-'] | V |
| Rated control supply voltage Us at DC (EF003980) | ['18', '30'] | V |
| Voltage type for actuating (EF008242) | DC | |
| Current measurement range (EF000417) | ['0.05', '750.0'] | A |
| Min. adjustable delay-on energization time (EF008190) | 0 | s |
| Max. permitted delay-on energization time (EF008189) | 999.9 | s |
| Min. adjustable off-delay time (EF008192) | 0 | s |
| Max. permitted off-delay time (EF008191) | 999.9 | s |
| Number of contacts as normally closed contact (EF008255) | 0 | |
| Number of contacts as normally open contact (EF008256) | 0 | |
| Number of contacts as change-over contact (EF008257) | 1 | |
| Width (EF000008) | 22.5 | mm |
| Height (EF000040) | 92.0 | mm |
| Depth (EF000049) | 91.0 | mm |