SIEMENS 3UG4815-1AA40 3UG4815-1AA40 SIEMENS Digital monitoring relay 3-phase supply voltage for IO-Link 50...60 Hz AC 3 x 160 to 6.. View larger
Images are for illustrative purposes only. Please refer to data sheet for details

3UG4815-1AA40 SIEMENS Digital monitoring relay 3-phase supply voltage for IO-Link 50...60 Hz AC 3 x 160 to 6..

3UG4815-1AA40

48151

SIEMENS

1 Pcs.

Digital monitoring relay 3-phase supply voltage for IO-Link 50...60 Hz AC 3 x 160 to 690 V Phase sequence, Phase failure Phase asymmetry Undervoltage and overvoltage Hysteresis 1-20 V Line stabilization delay Tripping delay time 1 change-over contact, screw terminal

Automation > Phase monitoring relay
Function relays

Product condition, packaging, certifications and applicable manufacturer warranty terms are confirmed with the quotation.

Request a Quote

Pricing and availability are confirmed for each enquiry. Add your required quantity to begin.

No account, online checkout or payment is required.

More info

Technical data

Digital monitoring relay 3-phase supply voltage for IO-Link 50...60 Hz AC 3 x 160 to 690 V Phase sequence, Phase failure Phase asymmetry Undervoltage and overvoltage Hysteresis 1-20 V Line stabilization delay Tripping delay time 1 change-over contact, screw terminal
product brand nameSIRIUS
product designationNetwork monitoring relay with digital setting
design of the product5 functions
product type designation3UG4
General technical data
product functionPhase monitoring relay
display version LEDNo
design of the displayLCD
insulation voltage for overvoltage category III according to IEC 60664
● with degree of pollution 2 rated value690 V
degree of pollution2
type of voltage
● for monitoringAC
● of the control supply voltageDC
surge voltage resistance rated value6 kV
protection class IPIP20
shock resistance according to IEC 60068-2-27sinusoidal half-wave 15g / 11 ms
vibration resistance according to IEC 60068-2-61 ... 6 Hz: 15 mm, 6 ... 500 Hz: 2g
mechanical service life (switching cycles) typical10 000 000
electrical endurance (switching cycles) at AC-15 at 230 V typical100 000
thermal current of the switching element with contacts maximum5 A
reference code according to IEC 81346-2K
relative repeat accuracy1 %
Substance Prohibitance (Date)05/01/2012
Product Function
product function
● undervoltage detectionYes
● overvoltage detectionYes
● phase sequence recognitionYes
● phase failure detectionYes
● asymmetry detectionYes
● overvoltage detection 3 phaseYes
● undervoltage detection 3 phasesYes
● voltage window recognition 3 phaseYes
● adjustable open/closed-circuit current principleYes
● external resetYes
● auto-RESETYes
Control circuit/ Control
control supply voltage at AC
● at 50 Hz rated value0 ... 0 V
● at 60 Hz rated value0 ... 0 V
control supply voltage at DC
● rated value24 ... 24 V
operating range factor control supply voltage rated value at DC
● initial value1
● full-scale value1
Measuring circuit
measurable voltage at AC690 ... 160 V
adjustable response delay time
● when starting0 ... 999.9 s
● with lower or upper limit violation0 ... 999.9 s
accuracy of digital display+/-1 digit
Precision
relative metering precision5 %
Communication/ Protocol
protocol is supported IO-Link protocolYes
IO-Link transfer rateCOM2 (38,4 kBaud)
point-to-point cycle time between master and IO-Link device minimum10 ms
type of voltage supply via input/output link masterYes
data volume
● of the address range of the inputs with cyclical transfer total4 byte
● of the address range of the outputs with cyclical transfer total2 byte
Auxiliary circuit
number of NC contacts delayed switching0
number of NO contacts delayed switching0
number of CO contacts delayed switching1
operating frequency with 3RT2 contactor maximum5 000 1/h
Main circuit
number of poles for main current circuit3
ampacity of the output relay at AC-15
● at 250 V at 50/60 Hz3 A
● at 400 V at 50/60 Hz3 A
ampacity of the output relay at DC-13
● at 24 V1 A
● at 125 V0.2 A
● at 250 V0.1 A
ampacity of the semiconductor output in SIO mode200 mA
operational current at 17 V minimum20 mA
continuous current of the DIAZED fuse link of the output relay4 A
Electromagnetic compatibility
conducted interference
● due to burst according to IEC 61000-4-42 kV
● due to conductor-earth surge according to IEC 61000-4-52 kV
● due to conductor-conductor surge according to IEC 61000-4-51 kV
field-based interference according to IEC 61000-4-310 V/m
electrostatic discharge according to IEC 61000-4-26 kV contact discharge / 8 kV air discharge
Galvanic isolation
galvanic isolation
● between input and outputYes
● between the voltage supply and other circuitsYes
Connections/ Terminals
product component removable terminal for auxiliary and control circuitYes
type of electrical connectionscrew-type terminals
type of connectable conductor cross-sections
● solid1x (0.5 ... 4 mm2), 2x (0.5 ... 2.5 mm2)
● finely stranded with core end processing1x (0.5 ... 2.5 mm2), 2x (0.5 ... 1.5 mm2)
● at AWG cables solid2x (20 ... 14)
● at AWG cables stranded2x (20 ... 14)
connectable conductor cross-section
● solid0.5 ... 4 mm²
● finely stranded with core end processing0.5 ... 2.5 mm²
AWG number as coded connectable conductor cross section
● solid20 ... 14
● stranded20 ... 14
tightening torque with screw-type terminals0.8 ... 1.2 N·m
Installation/ mounting/ dimensions
mounting positionany
fastening methodsnap-on mounting
height102 mm
width22.5 mm
depth91 mm
required spacing
● with side-by-side mounting
— forwards0 mm
— backwards0 mm
— upwards0 mm
— downwards0 mm
— at the side0 mm
● for grounded parts
— forwards0 mm
— backwards0 mm
— upwards0 mm
— at the side0 mm
— downwards0 mm
● for live parts
— forwards0 mm
— backwards0 mm
— upwards0 mm
— downwards0 mm
— at the side0 mm
Ambient conditions
installation altitude at height above sea level maximum2 000 m
ambient temperature
● during operation-25 ... +60 °C
● during storage-40 ... +85 °C
● during transport-40 ... +85 °C
Certificates/ approvals

Downloads and manuals

General Product ApprovalEMC

Confirmation

CCC

Manufacturer Declaration

UL

EAC

RCM

Declaration of ConformityTest CertificatesMarine / ShippingotherRailway

EC/EU-Declaration of Conformity

Special Test Certificate

Type Test Certificates/Test Report

DNV-GL

Confirmation

Vibration and Shock

Further information
Information- and Downloadcenter (Catalogs, Brochures,…)
Industry Mall (Online ordering system)
Cax online generator
Service&Support (Manuals, Certificates, Characteristics, FAQs,...)
Image database (product images, 2D dimension drawings, 3D models, device circuit diagrams, EPLAN macros, ...)
Characteristic: Derating
last modified:1/8/2021
Date
5/12/2022
Subject to change without notice
© Copyright Siemens 2022


Additional data

Product
Article Number (Market Facing Number)3UG4815-1AA40
Product DescriptionDigital monitoring relay 3-phase supply voltage for IO-Link 50...60 Hz AC 3 x 160 to 690 V Phase sequence, Phase failure Phase asymmetry Undervoltage and overvoltage Hysteresis 1-20 V Line stabilization delay Tripping delay time 1 change-over contact, screw terminal
Product familyLine monitoring
Product Lifecycle (PLM)PM300:Active Product
Price data
Region Specific PriceGroup / Headquarter Price Group41H / 41H
Surcharge for Raw MaterialsNone
Metal FactorLAO-----
Delivery information
Export Control RegulationsAL : N / ECCN : N
Standard lead time ex-works2 Day/Days
Net Weight (kg)0,142 Kg
Packaging Dimension32,00 x 99,00 x 111,00
Package size unit of measureMM
Quantity Unit1 Piece
Packaging Quantity1
Additional Product Information
EAN4011209895584
UPC040892870855
Commodity Code85364900
LKZ_FDB/ CatalogIDCC-IC10
Product Group5885
Group CodeR711
Country of originCzech Republic
Compliance with the substance restrictions according to RoHS directiveSince: 01.05.2012
Product classA: Standard product which is a stock item could be returned within the returns guidelines/period.
WEEE (2012/19/EU) Take-Back ObligationYes
REACH Art. 33 Duty to inform according to the current list of candidates

Information obligation imposed by Article 33, REACH Regulation: This product includes one or several articles in which the following substance of the candidate list is contained in concentrations higher than 0,1% weight by weight (w/w):

Lead

Based on the information currently available, we assume that these substances do not pose any risk if the articles are used as intended (including disposal). Please also refer to product documentation.

Information obligation imposed by Article 33, REACH Regulation: This product includes one or several articles in which the following substance of the candidate list is contained in concentrations higher than 0,1% weight by weight (w/w):

Lead monoxide (lead oxide)

Based on the information currently available, we assume that these substances do not pose any risk if the articles are used as intended (including disposal). Please also refer to product documentation.

Information obligation imposed by Article 33, REACH Regulation: This product includes one or several articles in which the following substance of the candidate list is contained in concentrations higher than 0,1% weight by weight (w/w):

Dicyclohexyl phthalate (DCHP)

Based on the information currently available, we assume that these substances do not pose any risk if the articles are used as intended (including disposal). Please also refer to product documentation.

Information obligation imposed by Article 33, REACH Regulation: This product includes one or several articles in which the following substance of the candidate list is contained in concentrations higher than 0,1% weight by weight (w/w):

Tris(2-chloroethyl) phosphate (TCEP)

Based on the information currently available, we assume that these substances do not pose any risk if the articles are used as intended (including disposal). Please also refer to product documentation.

Classifications
VersionClassification
eClass627-37-18-03
eClass7.127-37-18-03
eClass827-37-18-03
eClass927-37-18-03
eClass9.127-37-18-03
ETIM5EC001441
ETIM6EC001441
ETIM7EC001441
ETIM8EC001441
IDEA44727
UNSPSC1439-12-15-21
UNSPSC1539-12-15-21

ETIM data

ETIM: EC001441 - Phase monitoring relay

Value Unit
Type of electric connection (EF003961) Screw connection
With detachable clamps (EF003340) true
Rated control supply voltage Us at AC 50HZ (EF003978) ['0.0', '0.0']V
Rated control supply voltage Us at AC 60HZ (EF003979) ['0.0', '0.0']V
Rated control supply voltage Us at DC (EF003980) ['24', '24']V
Voltage type for actuating (EF008242) DC
Phase sequence monitoring (EF003412) true
Phase failure detection (EF003413) true
Function under voltage detection (EF003414) true
Function over voltage detection (EF003415) true
Phase imbalance monitoring (EF003416) true
Voltage measuring range (EF002486) ['160', '690']V
Min. adjustable delay-on energization time (EF008190) 0s
Max. permitted delay-on energization time (EF008189) 999.9s
Min. adjustable off-delay time (EF008192) 0s
Max. permitted off-delay time (EF008191) 999.9s
Number of contacts as normally closed contact (EF008255) 0
Number of contacts as normally open contact (EF008256) 0
Number of contacts as change-over contact (EF008257) 1
Width (EF000008) 22.5mm
Height (EF000040) 102.0mm
Depth (EF000049) 91.0mm



Product Datasheet

Electrica Online Product Datasheet Prepared from the current product description, catalog data and structured technical attributes.