Designed as a Siemens 3UG4641-2CS20 digital monitoring relay, this device provides active power, cos phi, and current monitoring to protect industrial motor loads from overcurrent and undercurrent conditions. Monitoring relays are essential safety devices that disconnect loads promptly when electrical parameters deviate from safe operating thresholds. Pricing, availability and lead time are confirmed per enquiry through an RFQ.
- product designation: Cos phi monitoring relay with digital setting
- product type designation: 3UG4
- General technical data product function: Active power monitoring relay
- design of the display: LCD
- ● with degree of pollution 3 rated value: 690 V
- degree of pollution: 3
- surge voltage resistance rated value: 6 kV
- protection class IP: IP20
- shock resistance according to IEC 60068-2-27: sinusoidal half-wave 15g / 11 ms
- vibration resistance according to IEC 60068-2-6: 1 ... 6 Hz: 15 mm, 6 ... 500 Hz: 2g
- mechanical service life (switching cycles) typical: 10 000 000
- reference code according to IEC 81346-2: K
- relative repeat accuracy: 1 %
- Substance Prohibitance (Date): 05/01/2012
- ● overcurrent detection 1 phase: Yes
- ● undercurrent detection 1 phase: Yes
More info
▲Technical data
Additional data
| Product | ||||||||||||||||||||||||||||||||||||||||
| Article Number (Market Facing Number) | 3UG4641-2CS20 | |||||||||||||||||||||||||||||||||||||||
| Product Description | Digital monitoring relay cos phi and current monitoring from 90-690 V AC 0vershoot and undershoot self-supplied 50 to 60 Hz AC Noise pulses delay 0.1 to 20 s Hysteresis for (I) 0.1 to 2 A 2 change-over contacts with or without fault buffer spring-type connection system | |||||||||||||||||||||||||||||||||||||||
| Product family | Power factor and active current monitoring | |||||||||||||||||||||||||||||||||||||||
| Product Lifecycle (PLM) | PM300:Active Product | |||||||||||||||||||||||||||||||||||||||
| Price data | ||||||||||||||||||||||||||||||||||||||||
| Region Specific PriceGroup / Headquarter Price Group | 41H / 41H | |||||||||||||||||||||||||||||||||||||||
| Surcharge for Raw Materials | None | |||||||||||||||||||||||||||||||||||||||
| Metal Factor | LAO----- | |||||||||||||||||||||||||||||||||||||||
| Delivery information | ||||||||||||||||||||||||||||||||||||||||
| Export Control Regulations | AL : N / ECCN : N | |||||||||||||||||||||||||||||||||||||||
| Standard lead time ex-works | 20 Day/Days | |||||||||||||||||||||||||||||||||||||||
| Net Weight (kg) | 0,153 Kg | |||||||||||||||||||||||||||||||||||||||
| Packaging Dimension | 29,00 x 99,00 x 107,00 | |||||||||||||||||||||||||||||||||||||||
| Package size unit of measure | MM | |||||||||||||||||||||||||||||||||||||||
| Quantity Unit | 1 Piece | |||||||||||||||||||||||||||||||||||||||
| Packaging Quantity | 1 | |||||||||||||||||||||||||||||||||||||||
| Additional Product Information | ||||||||||||||||||||||||||||||||||||||||
| EAN | 4011209665163 | |||||||||||||||||||||||||||||||||||||||
| UPC | 804766346309 | |||||||||||||||||||||||||||||||||||||||
| Commodity Code | 85364900 | |||||||||||||||||||||||||||||||||||||||
| LKZ_FDB/ CatalogID | CC-IC10 | |||||||||||||||||||||||||||||||||||||||
| Product Group | 5885 | |||||||||||||||||||||||||||||||||||||||
| Group Code | R711 | |||||||||||||||||||||||||||||||||||||||
| Country of origin | Germany | |||||||||||||||||||||||||||||||||||||||
| Compliance with the substance restrictions according to RoHS directive | Since: 01.05.2012 | |||||||||||||||||||||||||||||||||||||||
| Product class | A: Standard product which is a stock item could be returned within the returns guidelines/period. | |||||||||||||||||||||||||||||||||||||||
| WEEE (2012/19/EU) Take-Back Obligation | Yes | |||||||||||||||||||||||||||||||||||||||
| REACH Art. 33 Duty to inform according to the current list of candidates |
| |||||||||||||||||||||||||||||||||||||||
| Classifications | ||||||||||||||||||||||||||||||||||||||||
| ||||||||||||||||||||||||||||||||||||||||
ETIM data
ETIM: EC001443 - Effective power (cos phi) monitoring relay
| Value | Unit | |
|---|---|---|
| Type of electric connection (EF003961) | Spring clamp connection | |
| Rated control supply voltage Us at AC 50HZ (EF003978) | ['90.0', '690.0'] | V |
| Rated control supply voltage Us at AC 60HZ (EF003979) | ['90.0', '690.0'] | V |
| Rated control supply voltage Us at DC (EF003980) | ['-', '-'] | V |
| Voltage type for actuating (EF008242) | AC | |
| With detachable clamps (EF003340) | true | |
| Rated voltage (EF003977) | ['90', '690'] | V |
| Measurement current (EF008522) | ['0.2', '10.0'] | A |
| Rated operation frequency (EF007024) | ['50', '60'] | Hz |
| Number of phases (EF000351) | 1 | |
| Adjustable setting value for Cos-Phi (EF003418) | ['0.1', '0.99'] | |
| Min. adjustable delay-on energization time (EF008190) | 0 | s |
| Max. permitted delay-on energization time (EF008189) | 99 | s |
| Min. adjustable off-delay time (EF008192) | 0.1 | s |
| Max. permitted off-delay time (EF008191) | 20 | s |
| Number of contacts as normally closed contact (EF008255) | 0 | |
| Number of contacts as normally open contact (EF008256) | 0 | |
| Number of contacts as change-over contact (EF008257) | 2 | |
| Width (EF000008) | 22.5 | mm |
| Height (EF000040) | 103.0 | mm |
| Depth (EF000049) | 91.0 | mm |