SIEMENS 3UG4583-1CW30 3UG4583-1CW30 SIEMENS Insulation monitoring relay for ungrounded (IT) supply systems up to 400 V AC, 15-400 .. View larger
Images are for illustrative purposes only. Please refer to data sheet for details

3UG4583-1CW30 SIEMENS Insulation monitoring relay for ungrounded (IT) supply systems up to 400 V AC, 15-400 ..

3UG4583-1CW30

45831

SIEMENS

1 Pcs.

Insulation monitoring relay for ungrounded (IT) supply systems up to 400 V AC, 15-400 Hz and up to 600 V DC Measuring range 1-100 / 2-200 kohm Supply voltage 24-240 V AC/DC Width 45 mm 1 + 1 or 2 change-over contacts screw terminal

Automation > Insulation and earth fault monitoring relay
Function relays

Product condition, packaging, certifications and applicable manufacturer warranty terms are confirmed with the quotation.

Request a Quote

Pricing and availability are confirmed for each enquiry. Add your required quantity to begin.

No account, online checkout or payment is required.

More info

Technical data

Insulation monitoring relay for ungrounded (IT) supply systems up to 400 V AC, 15-400 Hz and up to 600 V DC Measuring range 1-100 / 2-200 kohm Supply voltage 24-240 V AC/DC Width 45 mm 1 + 1 or 2 change-over contacts screw terminal
product brand nameSIRIUS
product designationInsulation monitoring relay with analog setting
product type designation3UG4
General technical data
product functionInsulation monitor
type of voltage
● for monitoringAC/DC
● of the operating voltage for actuationAC/DC
● of the control supply voltageAC/DC
surge voltage resistance rated value4 000 V
protection class IPIP20
thermal current of the switching element with contacts maximum4 A
reference code according to IEC 81346-2K
Substance Prohibitance (Date)05/01/2012
Product Function
product function
● error memoryYes
Control circuit/ Control
control supply voltage at AC
● at 50 Hz rated value24 ... 240 V
● at 60 Hz rated value24 ... 240 V
control supply voltage at DC rated value24 ... 240 V
operating range factor control supply voltage rated value at DC
● initial value0.85
● full-scale value1.1
operating range factor control supply voltage rated value at AC at 50 Hz
● initial value0.85
● full-scale value1.1
operating range factor control supply voltage rated value at AC at 60 Hz
● initial value0.85
● full-scale value1.1
Measuring circuit
measurable line frequency15 ... 400 Hz
measurable voltage at AC400 ... 0 V
Auxiliary circuit
number of NC contacts for auxiliary contacts0
number of NC contacts delayed switching0
number of NO contacts for auxiliary contacts0
number of NO contacts delayed switching0
number of CO contacts
● delayed switching2
Main circuit
operating frequency rated value15 ... 400 Hz
Connections/ Terminals
product component removable terminal for auxiliary and control circuitNo
type of electrical connectionscrew-type terminals
type of connectable conductor cross-sections
● solid2x (0.75 ... 2.5 mm²)
● finely stranded with core end processing2x (0.75 ... 2.5 mm²)
connectable conductor cross-section
● solid0.75 ... 2.5 mm²
● finely stranded with core end processing0.75 ... 2.5 mm²
AWG number as coded connectable conductor cross section
● solid20 ... 12
● stranded18 ... 14
tightening torque with screw-type terminals0.6 ... 0.8 N·m
Installation/ mounting/ dimensions
mounting positionany
fastening methodsnap-on fastening on 35 mm standard rail
height78 mm
width45 mm
depth100 mm
required spacing
● with side-by-side mounting
— forwards0 mm
— backwards0 mm
— upwards0 mm
— downwards0 mm
— at the side0 mm
● for grounded parts
— forwards0 mm
— backwards0 mm
— upwards0 mm
— at the side0 mm
— downwards0 mm
● for live parts
— forwards0 mm
— backwards0 mm
— upwards0 mm
— downwards0 mm
— at the side0 mm
Ambient conditions
ambient temperature during operation-25 ... +60 °C
Certificates/ approvals

Downloads and manuals

General Product ApprovalEMCDeclaration of Conformity

CCC

Confirmation

UL

EAC

RCM

EC/EU-Declaration of Conformity

Declaration of ConformityTest CertificatesMarine / ShippingotherRailway

UK Declaration of Conformity

Special Test Certificate

RMRS / Russian Maritime Register

DNV-GL

Confirmation

Vibration and Shock

Further information
Information- and Downloadcenter (Catalogs, Brochures,…)
Industry Mall (Online ordering system)
Cax online generator
Service&Support (Manuals, Certificates, Characteristics, FAQs,...)
Image database (product images, 2D dimension drawings, 3D models, device circuit diagrams, EPLAN macros, ...)
Characteristic: Derating
last modified:8/26/2021
Date
5/4/2022
Subject to change without notice
© Copyright Siemens 2022


Additional data

Product
Article Number (Market Facing Number)3UG4583-1CW30
Product DescriptionInsulation monitoring relay for ungrounded (IT) supply systems up to 400 V AC, 15-400 Hz and up to 600 V DC Measuring range 1-100 / 2-200 kohm Supply voltage 24-240 V AC/DC Width 45 mm 1 + 1 or 2 change-over contacts screw terminal
Product familyOrdering Data Overview
Product Lifecycle (PLM)PM400:Phase Out Started
PLM Effective DateProduct phase-out since: 01.10.2021
Notes
Sucessor:successor product: 3UG4583-1CW31
Price data
Region Specific PriceGroup / Headquarter Price Group41H / 41H
Surcharge for Raw MaterialsNone
Metal FactorLAO-----
Delivery information
Export Control RegulationsAL : N / ECCN : EAR99
Standard lead time ex-works5 Day/Days
Net Weight (kg)0,270 Kg
Packaging Dimension50,00 x 80,00 x 105,00
Package size unit of measureMM
Quantity Unit1 Piece
Packaging Quantity1
Additional Product Information
EAN4011209901193
UPC040892923100
Commodity Code85364900
LKZ_FDB/ CatalogIDCC-IC10
Product Group5885
Group CodeR711
Country of originGermany
Compliance with the substance restrictions according to RoHS directiveSince: 01.05.2012
Product classA: Standard product which is a stock item could be returned within the returns guidelines/period.
WEEE (2012/19/EU) Take-Back ObligationYes
REACH Art. 33 Duty to inform according to the current list of candidates

Information obligation imposed by Article 33, REACH Regulation: This product includes one or several articles in which the following substance of the candidate list is contained in concentrations higher than 0,1% weight by weight (w/w):

Lead

Based on the information currently available, we assume that these substances do not pose any risk if the articles are used as intended (including disposal). Please also refer to product documentation.

Information obligation imposed by Article 33, REACH Regulation: This product includes one or several articles in which the following substance of the candidate list is contained in concentrations higher than 0,1% weight by weight (w/w):

Lead monoxide (lead oxide)

Based on the information currently available, we assume that these substances do not pose any risk if the articles are used as intended (including disposal). Please also refer to product documentation.

Classifications
VersionClassification
eClass627-37-18-07
eClass7.127-37-18-07
eClass827-37-18-07
eClass927-37-18-07
eClass9.127-37-18-07
ETIM5EC001444
ETIM6EC001444
ETIM7EC001444
ETIM8EC001444
UNSPSC1439-12-15-21
UNSPSC1539-12-15-21

ETIM data

ETIM: EC001444 - Insulation and earth fault monitoring relay

Value Unit
Function (EF000030) -
Type of electric connection (EF003961) Screw connection
Rated control supply voltage Us at AC 50HZ (EF003978) ['24.0', '240.0']V
Rated control supply voltage Us at AC 60HZ (EF003979) ['24.0', '240.0']V
Rated control supply voltage Us at DC (EF003980) ['24', '240']V
Voltage type for actuating (EF008242) AC/DC
With detachable clamps (EF003340) false
Rated voltage (EF003977) ['-', '-']V
Rated frequency (EF001663) ['15', '400']Hz
Line capacity (EF003419) 20.0µF
Response value impedance 1 (EF008202) ['1.0', '100.0']kOhm
Response value impedance 2 (EF008203) ['2.0', '200.0']kOhm
Indication of insulation value (EF003422) false
Error registration possible (EF003423) true
Number of contacts as normally closed contact (EF008255) 0
Number of contacts as normally open contact (EF008256) 0
Number of contacts as change-over contact (EF008257) 2
Width (EF000008) 45.0mm
Height (EF000040) 78.0mm
Depth (EF000049) 100.0mm



Product Datasheet

Electrica Online Product Datasheet Prepared from the current product description, catalog data and structured technical attributes.