3UG4501-2AA30 SIEMENS Analog monitoring relay Fill level monitoring Resistance monitoring from 2 to 200 kohm..
3UG4501-2AA30
45012
SIEMENS
1 Pcs.
Automation > (Fill) level monitoring relay
Function relays
Product condition, packaging, certifications and applicable manufacturer warranty terms are confirmed with the quotation.
Request a Quote
Pricing and availability are confirmed for each enquiry. Send this part and we will reply with price and lead time.
Request QuoteProduct Overview
3UG4501-2AA30 Siemens analog monitoring relay provides reliable protection by tracking resistance thresholds for liquid levels or material presence within industrial bins and reservoirs. These relays safeguard mechanical assets by initiating shutdown protocols or alerts when critical operating boundaries are breached. Pricing, availability and lead time are confirmed per enquiry through an RFQ.
- product designation: Level monitoring relay with analog setting
- product type designation: 3UG4
- manufacturer's article number of the optional sensor: 2-pole and 3-pole sensors 3UG3207
- General technical data product function: Monitoring relay for level monitoring
- display version LED: Yes
- — at 24 V maximum: 2 VA
- degree of pollution: 3
- ● of the control supply voltage: AC/DC
- surge voltage resistance rated value: 4 kV
- protection class IP: IP20
- shock resistance according to IEC 60068-2-27: sinusoidal half-wave 15g / 11 ms
- vibration resistance according to IEC 60068-2-6: 1 ... 6 Hz: 15 mm, 6 ... 500 Hz: 2g
- mechanical service life (switching cycles) typical: 10 000 000
- reference code according to IEC 81346-2: K
- relative repeat accuracy: 1 %
More info
▲Technical data
Additional data
| Product | |||||||||||||||||||||||||||||||||||||
| Article Number (Market Facing Number) | 3UG4501-2AA30 | ||||||||||||||||||||||||||||||||||||
| Product Description | Analog monitoring relay Fill level monitoring Resistance monitoring from 2 to 200 kohm 0vershoot and undershoot Supply voltage 24 V AC/DC 50 to 60 Hz DC and AC without galvanic isolation to measuring circuit 2-step or 1-step control Tripping delay 0.5 to 10 s 1 change-over contact spring-type connection system | ||||||||||||||||||||||||||||||||||||
| Product family | Level monitoring | ||||||||||||||||||||||||||||||||||||
| Product Lifecycle (PLM) | PM300:Active Product | ||||||||||||||||||||||||||||||||||||
| Price data | |||||||||||||||||||||||||||||||||||||
| Region Specific PriceGroup / Headquarter Price Group | 41H / 41H | ||||||||||||||||||||||||||||||||||||
| Surcharge for Raw Materials | None | ||||||||||||||||||||||||||||||||||||
| Metal Factor | LAO----- | ||||||||||||||||||||||||||||||||||||
| Delivery information | |||||||||||||||||||||||||||||||||||||
| Export Control Regulations | AL : N / ECCN : N | ||||||||||||||||||||||||||||||||||||
| Standard lead time ex-works | 2 Day/Days | ||||||||||||||||||||||||||||||||||||
| Net Weight (kg) | 0,123 Kg | ||||||||||||||||||||||||||||||||||||
| Packaging Dimension | 99,00 x 108,00 x 30,00 | ||||||||||||||||||||||||||||||||||||
| Package size unit of measure | MM | ||||||||||||||||||||||||||||||||||||
| Quantity Unit | 1 Piece | ||||||||||||||||||||||||||||||||||||
| Packaging Quantity | 1 | ||||||||||||||||||||||||||||||||||||
| Additional Product Information | |||||||||||||||||||||||||||||||||||||
| EAN | 4011209665316 | ||||||||||||||||||||||||||||||||||||
| UPC | Not available | ||||||||||||||||||||||||||||||||||||
| Commodity Code | 85364190 | ||||||||||||||||||||||||||||||||||||
| LKZ_FDB/ CatalogID | CC-IC10 | ||||||||||||||||||||||||||||||||||||
| Product Group | 5885 | ||||||||||||||||||||||||||||||||||||
| Group Code | R711 | ||||||||||||||||||||||||||||||||||||
| Country of origin | Czech Republic | ||||||||||||||||||||||||||||||||||||
| Compliance with the substance restrictions according to RoHS directive | Since: 01.05.2012 | ||||||||||||||||||||||||||||||||||||
| Product class | A: Standard product which is a stock item could be returned within the returns guidelines/period. | ||||||||||||||||||||||||||||||||||||
| WEEE (2012/19/EU) Take-Back Obligation | Yes | ||||||||||||||||||||||||||||||||||||
| REACH Art. 33 Duty to inform according to the current list of candidates |
| ||||||||||||||||||||||||||||||||||||
| Classifications | |||||||||||||||||||||||||||||||||||||
| |||||||||||||||||||||||||||||||||||||
ETIM data
ETIM: EC001447 - (Fill) level monitoring relay
| Value | Unit | |
|---|---|---|
| Cascadable (EF000507) | - | |
| Type of electric connection (EF003961) | Spring clamp connection | |
| Rated control supply voltage Us at AC 50HZ (EF003978) | ['24.0', '24.0'] | V |
| Rated control supply voltage Us at AC 60HZ (EF003979) | ['24.0', '24.0'] | V |
| Rated control supply voltage Us at DC (EF003980) | ['24', '24'] | V |
| Voltage type for actuating (EF008242) | AC/DC | |
| With detachable clamps (EF003340) | true | |
| Number of inputs for electrodes (EF003427) | 1 | |
| Min. adjustable operate delay time (EF008195) | 0.5 | s |
| Max. permitted operate delay time (EF008194) | 10 | s |
| Min. adjustable off-delay time (EF008192) | 0.5 | s |
| Max. permitted off-delay time (EF008191) | 10 | s |
| Response value sensitivity adjustable (EF003429) | true | |
| Number of contacts as normally closed contact (EF008255) | 0 | |
| Number of contacts as normally open contact (EF008256) | 0 | |
| Number of contacts as change-over contact (EF008257) | 1 | |
| Physical measurement principle (EF008238) | Other | |
| Width (EF000008) | 22.5 | mm |
| Height (EF000040) | 94.0 | mm |
| Depth (EF000049) | 91.0 | mm |