SIEMENS 3TH4355-0AM0 3TH4355-0AM0 SIEMENS Contactor relay, 55E, EN 50011, 5 NO + 5 NC, screw terminal AC operation 220 V AC 50 Hz.. View larger
Images are for illustrative purposes only. Please refer to data sheet for details

3TH4355-0AM0 SIEMENS Contactor relay, 55E, EN 50011, 5 NO + 5 NC, screw terminal AC operation 220 V AC 50 Hz..

3TH4355-0AM0

43550

SIEMENS

1 Pcs.

Contactor relay, 55E, EN 50011, 5 NO + 5 NC, screw terminal AC operation 220 V AC 50 Hz/264 V AC 60 Hz

Automation > Contactor relay
Contactor relays

Product condition, packaging, certifications and applicable manufacturer warranty terms are confirmed with the quotation.

Request a Quote

Pricing and availability are confirmed for each enquiry. Add your required quantity to begin.

No account, online checkout or payment is required.

More info

ETIM: EC000196 - Contactor relay

Value Unit
Mounting method (EF000003) -
Manual operation possible (EF005881) -
Interface (EF000594) -
With LED indication (EF005950) -
Rated control supply voltage Us at DC (EF003980) ['-', '-']V
Voltage type for actuating (EF008242) AC
Rated operation current Ie, 400 V (EF001378) 6A
Connection type auxiliary circuit (EF006820) Screw connection
Number of auxiliary contacts as normally closed contact (EF001377) 5
Number of auxiliary contacts as normally open contact (EF001376) 5
Number of auxiliary contacts as normally closed contact, delayed switching (EF007281) 0
Number of auxiliary contacts as normally open contact, leading (EF007282) 0
Number of auxiliary contacts as change-over contact (EF003531) 0
Rated control supply voltage Us at AC 50HZ (EF003978) -V
Rated control supply voltage Us at AC 60HZ (EF003979) -V


Contactor relay, 55E, EN 50011, 5 NO + 5 NC, screw terminal AC operation 220 V AC 50 Hz/264 V AC 60 Hz
product designationAuxiliary contactor
product type designation3TH4
Size of contactor0
protection class IP on the frontIP20
reference code acc. to DIN EN 81346-2K
● ambient temperature during operation-25 ... +55 °C
Type of voltage of the control supply voltageAC
● Control supply voltage at AC at 50 Hz rated value220 V
● Control supply voltage at AC at 60 Hz rated value264 V
control supply voltage frequency
● 1 rated value50 Hz
● 2 rated value60 Hz
● number of NC contacts for auxiliary contacts5
● Number of NC contacts for auxiliary contacts delayed switching0
● Number of NC contacts for auxiliary contacts lagging switching0
● Number of NC contacts for auxiliary contacts make-before-break switching0
● number of NO contacts for auxiliary contacts5
● Number of NO contacts for auxiliary contacts delayed switching0
● Number of NO contacts for auxiliary contacts leading contact0
● Number of NO contacts for auxiliary contacts make-before-break switching0
number of CO contacts for auxiliary contacts0
Identification number and letter for switching elements55 E
Operating current at AC-15
● at 230 V rated value10 A
● at 400 V rated value6 A
mounting typescrew and snap-on mounting onto 35 mm standard mounting rail according to DIN EN 50022
height78 mm
width55 mm
depth102 mm
type of electrical connection for auxiliary and control current circuitscrew-type terminals
B10 value with high demand rate acc. to SN 319201 000 000; With 0.3 x Ie
T1 value for proof test interval or service life acc. to IEC 6150820 y
protection against electrical shockfinger-safe
Further information
Information- and Downloadcenter (Catalogs, Brochures,…)
Industry Mall (Online ordering system)
Cax online generator
Service&Support (Manuals, Certificates, Characteristics, FAQs,...)
Image database (product images, 2D dimension drawings, 3D models, device circuit diagrams, EPLAN macros, ...)
Characteristic: Tripping characteristics, I²t, Let-through current
Further characteristics (e.g. electrical endurance, switching frequency)
last modified:08/25/2020


Product
Article Number (Market Facing Number)3TH4355-0AM0
Product DescriptionContactor relay, 55E, EN 50011, 5 NO + 5 NC, screw terminal AC operation 220 V AC 50 Hz/264 V AC 60 Hz
Product familyNot available
Product Lifecycle (PLM)PM490:Start of final year of support
PLM Effective DateProduct discontinued since: 29.02.2020
Notes
Product is no longer available
If you need assistance please contact our local Siemens office
Price data
Price Group41A
Surcharge for Raw MaterialsNone
Metal FactorLDO-----
Delivery information
Export Control RegulationsECCN : N / AL : N
Standard lead time ex-works50 Day/Days
Net Weight (kg)0,452 Kg
Product Dimensions (W x L x H)Not available
Packaging Dimension58,00 x 82,00 x 106,00
Package size unit of measureMM
Quantity Unit1 Piece
Packaging Quantity1
Additional Product Information
EAN4011209049277
UPC754554930558
Commodity Code85364900
LKZ_FDB/ CatalogIDCC-IC10
Product Group5801
Group CodeR711
Country of originTurkey
Compliance with the substance restrictions according to RoHS directiveProduct is not RoHS-compliant
Product classA: Standard product which is a stock item could be returned within the returns guidelines/period.
WEEE (2012/19/EU) Take-Back ObligationYes
REACH Art. 33 Duty to inform according to the current list of candidates
There is currently no information on SVHC (Substances of Very High Concern http://echa.europa.eu/web/guest/candidate-list-table) from the supply chain and our established procedures for screening our products for Substances of Very High Concern.We compare our products regularly with the information of the upstream users with regard to the substances indicated in the candidate list in accordance with the requirements of the REACH regulation. As soon as we have new findings, our information will be updated accordingly.
Classifications
Not available

Product Datasheet