View larger
3SK2122-2AA10 SIEMENS SIRIUS safety relay Basic unit 3SK2 series 20 F-DI, 4 F-DQ, 2 DQ, 24 V DC Can be param..
3SK2122-2AA10
21222
SIEMENS
1 Pcs.
Automation > Device for monitoring of safety-related circuits
Limit Switches and safety relays
Product condition, packaging, certifications and applicable manufacturer warranty terms are confirmed with the quotation.
Request a Quote
Pricing and availability are confirmed for each enquiry. Send this part and we will reply with price and lead time.
Request QuoteProduct Overview
The Siemens 3SK2122-2AA10 is a SIRIUS safety relay basic unit utilized in automated industrial environments to monitor safety functions such as emergency stops and protective door positions. Central control units of this type process diverse sensor signals to ensure reliable hazard shutdown across complex machinery lines.
Pricing, availability and lead time are confirmed per enquiry through an RFQ.
- product category: Safety relay: Safety relay
- product designation: Base-Unit: Base-Unit
- design of the product: 20 F-DI: 4 F-DQ, 2 DQ
- ● EMERGENCY STOP function: Yes: Yes
- ● protective door monitoring: Yes: Yes
- ● protective door monitoring with tumbler: Yes: Yes
- ● muting: 2 sensor-parallel: Yes
- ● muting: 4 sensor-parallel: Yes
- ● muting: 4 sensor-sequential: Yes
- ● monitoring parameterizable: Yes: Yes
- ● evaluation: electro-sensitive protective equipment: Yes: Yes
- ● evaluation: selector switch: Yes: Yes
- ● pressure-sensitive mat monitoring: Yes: Yes
- ● evaluation: two-hand operator panel: Yes: Yes
- ● evaluation: enabling switch: Yes: Yes
- ● monitored start-up: Yes: Yes
More info
▲Technical data
Additional data
| Product | |||||||||||||||||||||||||||||||||||||
| Article Number (Market Facing Number) | 3SK2122-2AA10 | ||||||||||||||||||||||||||||||||||||
| Product Description | SIRIUS safety relay Basic unit 3SK2 series 20 F-DI, 4 F-DQ, 2 DQ, 24 V DC Can be parameterized via SIRIUS Safety ES 45 mm overall width Spring-type terminal (push-in) up to SILCL 3 (DIN EN 62061) Up to Performance Level E (ISO 13849-1) Output expansions 3SK1 and fail-safe motor starters 3RM1 via device connector connectable | ||||||||||||||||||||||||||||||||||||
| Product family | SIRIUS 3SK2 basic units | ||||||||||||||||||||||||||||||||||||
| Product Lifecycle (PLM) | PM300:Active Product | ||||||||||||||||||||||||||||||||||||
| Price data | |||||||||||||||||||||||||||||||||||||
| Region Specific PriceGroup / Headquarter Price Group | 41L / 41L | ||||||||||||||||||||||||||||||||||||
| Surcharge for Raw Materials | None | ||||||||||||||||||||||||||||||||||||
| Metal Factor | None | ||||||||||||||||||||||||||||||||||||
| Delivery information | |||||||||||||||||||||||||||||||||||||
| Export Control Regulations | AL : N / ECCN : EAR99 | ||||||||||||||||||||||||||||||||||||
| Standard lead time ex-works | 80 Day/Days | ||||||||||||||||||||||||||||||||||||
| Net Weight (kg) | 0,390 Kg | ||||||||||||||||||||||||||||||||||||
| Packaging Dimension | 111,00 x 153,00 x 62,00 | ||||||||||||||||||||||||||||||||||||
| Package size unit of measure | MM | ||||||||||||||||||||||||||||||||||||
| Quantity Unit | 1 Piece | ||||||||||||||||||||||||||||||||||||
| Packaging Quantity | 1 | ||||||||||||||||||||||||||||||||||||
| Additional Product Information | |||||||||||||||||||||||||||||||||||||
| EAN | 4047621004587 | ||||||||||||||||||||||||||||||||||||
| UPC | 804766163906 | ||||||||||||||||||||||||||||||||||||
| Commodity Code | 85371098 | ||||||||||||||||||||||||||||||||||||
| LKZ_FDB/ CatalogID | CC-IC10 | ||||||||||||||||||||||||||||||||||||
| Product Group | 3761 | ||||||||||||||||||||||||||||||||||||
| Group Code | R711 | ||||||||||||||||||||||||||||||||||||
| Country of origin | Germany | ||||||||||||||||||||||||||||||||||||
| Compliance with the substance restrictions according to RoHS directive | Since: 28.05.2009 | ||||||||||||||||||||||||||||||||||||
| Product class | A: Standard product which is a stock item could be returned within the returns guidelines/period. | ||||||||||||||||||||||||||||||||||||
| WEEE (2012/19/EU) Take-Back Obligation | Yes | ||||||||||||||||||||||||||||||||||||
| REACH Art. 33 Duty to inform according to the current list of candidates |
| ||||||||||||||||||||||||||||||||||||
| Classifications | |||||||||||||||||||||||||||||||||||||
| |||||||||||||||||||||||||||||||||||||
ETIM data
ETIM: EC001449 - Device for monitoring of safety-related circuits
| Value | Unit | |
|---|---|---|
| Release-delay (EF001129) | - | s |
| Model (EF000010) | - | |
| Performance level according to EN ISO 13849-1 (EF007399) | - | |
| Evaluation inputs (EF008245) | - | |
| Category according to EN 954-1 (EF006782) | - | |
| Suitable for monitoring of position switches (EF007270) | true | |
| Suitable for monitoring of emergency-stop circuits (EF007268) | true | |
| Suitable for monitoring of valves (EF007272) | true | |
| Suitable for monitoring of optoelectronic protection equipment (EF007269) | true | |
| Suitable for monitoring of tactile sensors (EF007271) | - | |
| Suitable for monitoring of magnetic switches (EF007266) | true | |
| Suitable for monitoring of proximity switches (EF007267) | true | |
| Type of electric connection (EF003961) | Spring clamp connection | |
| Rail mounting possible (EF003972) | FALSE | |
| Rated control supply voltage Us at AC 50HZ (EF003978) | ['-', '-'] | V |
| Rated control supply voltage Us at AC 60HZ (EF003979) | ['-', '-'] | V |
| Rated control supply voltage Us at DC (EF003980) | ['24', '24'] | V |
| Voltage type for actuating (EF008242) | DC | |
| With detachable clamps (EF003340) | true | |
| With start input (EF003342) | - | |
| With muting function (EF004057) | false | |
| With feedback circuit (EF003343) | - | |
| Number of outputs, safety related, undelayed, with contact (EF003344) | 0 | |
| Number of outputs, safety related, delayed, with contact (EF003345) | - | |
| Number of outputs, safety related, undelayed, semiconductors (EF003346) | 4 | |
| Number of outputs, safety related, delayed, semiconductors (EF003347) | - | |
| Number of outputs, signalling function, undelayed, with contact (EF003348) | - | |
| Number of outputs, signalling function, delayed, with contact (EF003349) | - | |
| Number of outputs, signalling function, undelayed, semiconductors (EF003350) | - | |
| Number of outputs, signalling function, delayed, semiconductors (EF003351) | - | |
| Type of safety according to IEC 61496-1 (EF004105) | - | |
| Stop category according to IEC 60204 (EF007498) | 0 + 1 | |
| SIL according to IEC 61508 (EF009889) | 3 | |
| With approval for TÜV (EF004144) | true | |
| With approval for BG BIA (EF004145) | - | |
| With approval according to UL (EF001783) | true | |
| Width (EF000008) | 45.0 | mm |
| Height (EF000040) | 100.0 | mm |
| Depth (EF000049) | 124.5 | mm |