View larger
3SE6614-4CA01 SIEMENS Magnet switch Contact block 25 x 88 mm, for door hinge on the left Contact elements: S..
3SE6614-4CA01
66144
SIEMENS
1 Pcs.
Automation > Magnetic proximity switch
Limit Switches and safety relays
Product condition, packaging, certifications and applicable manufacturer warranty terms are confirmed with the quotation.
Request a Quote
Pricing and availability are confirmed for each enquiry. Send this part and we will reply with price and lead time.
Request QuoteProduct Overview
This 3SE6614-4CA01 Siemens contact block magnet switch serves as an interlock device for monitoring access points on industrial safety barriers. Magnetic contact blocks are commonly utilized on machine access doors to ensure equipment halts immediately if unauthorized entry is attempted. Pricing, availability and lead time are confirmed per enquiry through an RFQ.
- product designation: Magnetically operated switch
- design of the product: Rectangular sensor unit
- product type designation: 3SE66
- suitability for use safety-related circuits: Yes
- ● positive opening: No
- ● control function for downstream devices: No
- ● cross-circuit/short-circuit recognition: Yes
- type of voltage of the operating voltage: DC
- protection class IP: IP67
- shock resistance according to IEC 60068-2-27: Sinusoidal half-wave 30g / 11 ms
- vibration resistance according to IEC 60068-2-6: 10 ... 55 Hz: 1 mm
- reference code according to IEC 81346-2: S
- Substance Prohibitance (Date): 07/01/2006
- type of voltage: DC
- height of the sensor: 25 mm
- length of the sensor: 13 mm
More info
▲Technical data
Additional data
| Product | ||||||||||||||||||||||||||||||||||
| Article Number (Market Facing Number) | 3SE6614-4CA01 | |||||||||||||||||||||||||||||||||
| Product Description | Magnet switch Contact block 25 x 88 mm, for door hinge on the left Contact elements: Safety contacts 2 NC with M8 connector, 4-pole with combi connection Screw/latching connection with LED, the matching solenoid 3SE6714-2CA or offset by 90° 3SE6724-2CA | |||||||||||||||||||||||||||||||||
| Product family | SIRIUS 3SE66, 3SE67 non-contact safety switches, magnet | |||||||||||||||||||||||||||||||||
| Product Lifecycle (PLM) | PM300:Active Product | |||||||||||||||||||||||||||||||||
| Price data | ||||||||||||||||||||||||||||||||||
| Region Specific PriceGroup / Headquarter Price Group | 41K / 41K | |||||||||||||||||||||||||||||||||
| Surcharge for Raw Materials | None | |||||||||||||||||||||||||||||||||
| Metal Factor | None | |||||||||||||||||||||||||||||||||
| Delivery information | ||||||||||||||||||||||||||||||||||
| Export Control Regulations | AL : N / ECCN : N | |||||||||||||||||||||||||||||||||
| Standard lead time ex-works | 60 Day/Days | |||||||||||||||||||||||||||||||||
| Net Weight (kg) | 0,040 Kg | |||||||||||||||||||||||||||||||||
| Packaging Dimension | 25,00 x 95,00 x 10,00 | |||||||||||||||||||||||||||||||||
| Package size unit of measure | MM | |||||||||||||||||||||||||||||||||
| Quantity Unit | 1 Piece | |||||||||||||||||||||||||||||||||
| Packaging Quantity | 1 | |||||||||||||||||||||||||||||||||
| Additional Product Information | ||||||||||||||||||||||||||||||||||
| EAN | 4047621002613 | |||||||||||||||||||||||||||||||||
| UPC | 804766058561 | |||||||||||||||||||||||||||||||||
| Commodity Code | 85365080 | |||||||||||||||||||||||||||||||||
| LKZ_FDB/ CatalogID | CC-IC10 | |||||||||||||||||||||||||||||||||
| Product Group | 3750 | |||||||||||||||||||||||||||||||||
| Group Code | R711 | |||||||||||||||||||||||||||||||||
| Country of origin | Germany | |||||||||||||||||||||||||||||||||
| Compliance with the substance restrictions according to RoHS directive | Since: 01.07.2006 | |||||||||||||||||||||||||||||||||
| Product class | A: Standard product which is a stock item could be returned within the returns guidelines/period. | |||||||||||||||||||||||||||||||||
| WEEE (2012/19/EU) Take-Back Obligation | Yes | |||||||||||||||||||||||||||||||||
| REACH Art. 33 Duty to inform according to the current list of candidates |
| |||||||||||||||||||||||||||||||||
| Classifications | ||||||||||||||||||||||||||||||||||
| ||||||||||||||||||||||||||||||||||
ETIM data
ETIM: EC002544 - Magnetic proximity switch
| Value | Unit | |
|---|---|---|
| Type of interface for safety communication (EF003956) | - | |
| Construction type housing (EF004008) | - | |
| With status indication (EF001602) | - | |
| Type of switching output (EF003962) | - | |
| Degree of protection (NEMA) (EF011959) | - | |
| Number of semiconductor outputs with signalling function (EF003945) | 0 | |
| Number of contact energized outputs with signalling function (EF003946) | 0 | |
| Number of protected semiconductor outputs (EF003951) | 0 | |
| Number of protected contact energized outputs (EF003952) | 0 | |
| Type of actuation (EF006949) | Magnet | |
| Type of electric connection (EF003961) | Connector M8 | |
| Width sensor (EF007094) | 88.0 | mm |
| Height of sensor (EF007283) | 25.0 | mm |
| Length of sensor (EF007334) | 13.0 | mm |
| Explosion safety category for gas (EF003997) | None | |
| Explosion safety category for dust (EF003998) | None | |
| Material housing (EF001596) | Plastic | |
| Coating housing (EF001601) | - | |
| Protected switch distance OFF (EF004011) | 17.0 | mm |
| Protected switch distance ON (EF004012) | 7.0 | mm |
| Category according to EN 954-1 (EF006782) | 4 | |
| SIL according to IEC 61508 (EF009889) | 3 | |
| Performance level according to EN ISO 13849-1 (EF007399) | Level e | |
| Ambient temperature (EF002386) | ['-25', '70'] | °C |
| Mechanical mounting condition for sensor (EF004041) | Quasi-flat | |
| Rated supply voltage at AC 50 Hz (EF007076) | ['-', 'DC'] | V |
| Rated supply voltage at AC 60 Hz (EF007077) | ['-', 'DC'] | V |
| Rated supply voltage at DC (EF007078) | ['-', 'DC'] | V |
| Voltage type (EF000187) | DC | |
| Cross-/short circuit identification possible (EF004093) | true | |
| With monitoring function downstream switching devices (EF004052) | false | |
| Suitable for safety functions (EF001597) | true | |
| Degree of protection (IP) (EF005474) | IP67 | |
| Min. output current (EF004045) | - | mA |
| Max. output current at protected output (EF004035) | - | mA |
| Diameter sensor (EF007111) | - | mm |
| Switching distance (EF003647) | - | mm |