View larger
3SE5162-0BA00-1CA0 SIEMENS Basic switch for position switch 3SE5162 Metal enclosure XL, 56 mm wide Device co..
3SE5162-0BA00-1CA0
51620
SIEMENS
1 Pcs.
Automation > End switch
Limit Switches and safety relays
Product condition, packaging, certifications and applicable manufacturer warranty terms are confirmed with the quotation.
Request a Quote
Pricing and availability are confirmed for each enquiry. Send this part and we will reply with price and lead time.
Request QuoteProduct Overview
A Siemens 3SE5162-0BA00-1CA0 basic switch for position switch 3SE5162 functions as a core electromechanical switching unit integrated into industrial safety and monitoring setups to detect physical limits. Facilities rely on such devices to interrupt control signals when safeguarding moving industrial assets. Pricing, availability and lead time are confirmed per enquiry through an RFQ.
- product designation: Mechanical safety switches
- product type designation: 3SE5
- ● of the supplied switching contacts: 1x 3SE5000-0BA00, 1x 3SE5060-0BA00
- ● of the supplied empty enclosure with cover: 3SE5162-0AA00-1CA0, on request
- suitability for use safety switch: Yes
- General technical data product function positive opening: Yes
- insulation voltage rated value: 400 V
- degree of pollution: class 3
- surge voltage resistance rated value: 6 kV
- protection class IP: IP66/IP67
- ● according to IEC 60068-2-27: 30g / 11 ms
- vibration resistance according to IEC 60068-2-6: 0.35 mm/5g
- mechanical service life (switching cycles) typical: 5 000 000
- thermal current: 10 A
- reference code according to IEC 81346-2: B
- continuous current of the C characteristic MCB: 1 A
- for a short-circuit current smaller than 400 A:
More info
▲Technical data
Additional data
| Product | ||||||||||||||||||||||||||||||||||||||||
| Article Number (Market Facing Number) | 3SE5162-0BA00-1CA0 | |||||||||||||||||||||||||||||||||||||||
| Product Description | Basic switch for position switch 3SE5162 Metal enclosure XL, 56 mm wide Device connection 3x(M20 x 1.5) IP66/IP67 2 x (1 NO/2 NC) Slow-action contacts without actuator head with increased corrosion protection | |||||||||||||||||||||||||||||||||||||||
| Product family | Enclosure width 56 mm, XL | |||||||||||||||||||||||||||||||||||||||
| Product Lifecycle (PLM) | PM300:Active Product | |||||||||||||||||||||||||||||||||||||||
| Price data | ||||||||||||||||||||||||||||||||||||||||
| Region Specific PriceGroup / Headquarter Price Group | 41K / 41K | |||||||||||||||||||||||||||||||||||||||
| Surcharge for Raw Materials | None | |||||||||||||||||||||||||||||||||||||||
| Metal Factor | LA------ | |||||||||||||||||||||||||||||||||||||||
| Delivery information | ||||||||||||||||||||||||||||||||||||||||
| Export Control Regulations | AL : N / ECCN : N | |||||||||||||||||||||||||||||||||||||||
| Standard lead time ex-works | 10 Day/Days | |||||||||||||||||||||||||||||||||||||||
| Net Weight (kg) | 0,480 Kg | |||||||||||||||||||||||||||||||||||||||
| Packaging Dimension | 56,00 x 166,50 x 77,50 | |||||||||||||||||||||||||||||||||||||||
| Package size unit of measure | MM | |||||||||||||||||||||||||||||||||||||||
| Quantity Unit | 1 Piece | |||||||||||||||||||||||||||||||||||||||
| Packaging Quantity | 1 | |||||||||||||||||||||||||||||||||||||||
| Additional Product Information | ||||||||||||||||||||||||||||||||||||||||
| EAN | 4011209862869 | |||||||||||||||||||||||||||||||||||||||
| UPC | 662643852516 | |||||||||||||||||||||||||||||||||||||||
| Commodity Code | 85365080 | |||||||||||||||||||||||||||||||||||||||
| LKZ_FDB/ CatalogID | CC-IC10 | |||||||||||||||||||||||||||||||||||||||
| Product Group | 5317 | |||||||||||||||||||||||||||||||||||||||
| Group Code | R711 | |||||||||||||||||||||||||||||||||||||||
| Country of origin | Germany | |||||||||||||||||||||||||||||||||||||||
| Compliance with the substance restrictions according to RoHS directive | Since: 01.07.2006 | |||||||||||||||||||||||||||||||||||||||
| Product class | C: products manufactured / produced to order, which cannot be reused or re-utilised or be returned against credit. | |||||||||||||||||||||||||||||||||||||||
| WEEE (2012/19/EU) Take-Back Obligation | Yes | |||||||||||||||||||||||||||||||||||||||
| REACH Art. 33 Duty to inform according to the current list of candidates |
| |||||||||||||||||||||||||||||||||||||||
| Classifications | ||||||||||||||||||||||||||||||||||||||||
| ||||||||||||||||||||||||||||||||||||||||
ETIM data
ETIM: EC000030 - End switch
| Value | Unit | |
|---|---|---|
| Degree of protection (NEMA) (EF011959) | - | |
| Width sensor (EF007094) | 56.0 | mm |
| Height of sensor (EF007283) | 37.3 | mm |
| Length of sensor (EF007334) | 107.7 | mm |
| Rated operation current Ie at AC-15, 24 V (EF007084) | 6 | A |
| Rated operation current Ie at AC-15, 125 V (EF007082) | 6 | A |
| Rated operation current Ie at AC-15, 230 V (EF001385) | - | A |
| Rated operation current Ie at DC-13, 24 V (EF007087) | 3 | A |
| Rated operation current Ie at DC-13, 125 V (EF007085) | 0.55 | A |
| Rated operation current Ie at DC-13, 230 V (EF001386) | - | A |
| Switching function (EF000189) | Slow-action switch | |
| Switching function latching (EF007447) | false | |
| Output electronic (EF006987) | FALSE | |
| Forced opening (EF006694) | true | |
| Number of safety auxiliary contacts (EF006940) | 2 | |
| Number of contacts as normally closed contact (EF008255) | 2 | |
| Number of contacts as normally open contact (EF008256) | 2 | |
| Number of contacts as change-over contact (EF008257) | 1 | |
| Type of interface (EF006977) | None | |
| Type of interface for safety communication (EF003956) | None | |
| Construction type housing (EF004008) | Cuboid | |
| Material housing (EF001596) | Metal | |
| Coating housing (EF001601) | Lacquered | |
| Type of control element (EF006976) | None | |
| Alignment of the control element (EF008793) | Roller cam straight | |
| Type of electric connection (EF003961) | Cable entry metrical | |
| With status indication (EF001602) | false | |
| Suitable for safety functions (EF001597) | true | |
| Explosion safety category for gas (EF003997) | None | |
| Explosion safety category for dust (EF003998) | None | |
| Ambient temperature during operating (EF007515) | ['-25', '85'] | °C |
| Degree of protection (IP) (EF005474) | IP66/IP67 | |
| Diameter sensor (EF007111) | - | mm |