View larger
3SE5132-1QV20 SIEMENS Safety position switch with separate actuator Plastic enclosure 40 mm 1 x (M20 x 1.5) ..
3SE5132-1QV20
51321
SIEMENS
1 Pcs.
Automation > Position switch with separate actuator
Limit Switches and safety relays
Product condition, packaging, certifications and applicable manufacturer warranty terms are confirmed with the quotation.
Request a Quote
Pricing and availability are confirmed for each enquiry. Send this part and we will reply with price and lead time.
Request QuoteProduct Overview
A safety position switch with a separate actuator, the Siemens 3SE5132-1QV20 is utilized across industrial installations to monitor the position of safety guards and doors. Mechanical safety position switches break control circuits positively when protective covers are displaced, preventing machinery accidents.
Pricing, availability and lead time are confirmed per enquiry through an RFQ.
- product designation: Mechanical safety switches
- product type designation: 3SE5
- ● of the supplied empty enclosure with cover: 3SE5132-0AA00
- suitability for use safety switch: Yes
- General technical data product function positive opening: Yes
- insulation voltage rated value: 400 V
- degree of pollution: class 3
- surge voltage resistance rated value: 6 kV
- protection class IP: IP66/IP67
- ● according to IEC 60068-2-27: 30g / 11 ms
- vibration resistance according to IEC 60068-2-6: 0.35 mm/5g
- mechanical service life (switching cycles) typical: 1 000 000
- thermal current: 10 A
- material of the enclosure of the switch head: plastic
- reference code according to IEC 81346-2: B
- continuous current of the C characteristic MCB: 1 A
More info
▲Technical data
| Safety position switch with separate actuator Plastic enclosure 40 mm 1 x (M20 x 1.5) Slow-action contacts 1 NO+2 NC with 2 LEDs yellow/green 24 V DC 5 directions of approaches The matching separate actuator 3SE5000-0AV0. must be ordered separately | ||||||||||||||||||||||||||
| product brand name | SIRIUS | |||||||||||||||||||||||||
| product designation | Mechanical safety switches | |||||||||||||||||||||||||
| product type designation | 3SE5 | |||||||||||||||||||||||||
| manufacturer's article number | ||||||||||||||||||||||||||
| ● of the optional actuators | 3SE5000-0AV01 standard actuator, 3SE5000-0AV02 actuator with vertical mounting, 3SE5000-0AV03 actuator with horizontal mounting, 3SE5000-0AV04 radius actuator left, 3SE5000-0AV05 universal actuator, 3SE5000-0AV06 radius actuator right, 3SE5000-0AV07 heavy-duty actuator, 3SE5000-0AW11 plastic actuator, 3SE5000-0AW21 stainless steel actuator | |||||||||||||||||||||||||
| ● of the supplied empty enclosure with cover | 3SE5132-0AA00 | |||||||||||||||||||||||||
| suitability for use safety switch | Yes | |||||||||||||||||||||||||
| General technical data | ||||||||||||||||||||||||||
| product function positive opening | Yes | |||||||||||||||||||||||||
| insulation voltage rated value | 400 V | |||||||||||||||||||||||||
| degree of pollution | class 3 | |||||||||||||||||||||||||
| surge voltage resistance rated value | 6 kV | |||||||||||||||||||||||||
| protection class IP | IP66/IP67 | |||||||||||||||||||||||||
| shock resistance | ||||||||||||||||||||||||||
| ● according to IEC 60068-2-27 | 30g / 11 ms | |||||||||||||||||||||||||
| vibration resistance according to IEC 60068-2-6 | 0.35 mm/5g | |||||||||||||||||||||||||
| mechanical service life (switching cycles) typical | 1 000 000 | |||||||||||||||||||||||||
| electrical endurance (switching cycles) with contactor 3RH11, 3RT1016, 3RT1017, 3RT1024, 3RT1025, 3RT1026 typical | 1 000 000 | |||||||||||||||||||||||||
| Electrical operating cycles in one hour with contactor 3RH11, 3RT1016, 3RT1017, 3RT1024, 3RT1025, 3RT1026 | 6 000 | |||||||||||||||||||||||||
| thermal current | 10 A | |||||||||||||||||||||||||
| material of the enclosure of the switch head | plastic | |||||||||||||||||||||||||
| reference code according to IEC 81346-2 | B | |||||||||||||||||||||||||
| continuous current of the C characteristic MCB | 1 A; for a short-circuit current smaller than 400 A | |||||||||||||||||||||||||
| continuous current of the quick DIAZED fuse link | 10 A; for a short-circuit current smaller than 400 A | |||||||||||||||||||||||||
| continuous current of the DIAZED fuse link gG | 6 A; for a short-circuit current smaller than 400 A | |||||||||||||||||||||||||
| active principle | mechanical | |||||||||||||||||||||||||
| repeat accuracy | 0.05 mm | |||||||||||||||||||||||||
| Substance Prohibitance (Date) | 07/01/2006 | |||||||||||||||||||||||||
| minimum actuating force in directions of actuation | 20 N | |||||||||||||||||||||||||
| length of the sensor | 110 mm | |||||||||||||||||||||||||
| width of the sensor | 40 mm | |||||||||||||||||||||||||
| design of the switching contact | mechanical | |||||||||||||||||||||||||
| number of NC contacts for auxiliary contacts | 2 | |||||||||||||||||||||||||
| number of NO contacts for auxiliary contacts | 1 | |||||||||||||||||||||||||
| operational current at DC-13 | ||||||||||||||||||||||||||
| ● at 24 V rated value | 3 A | |||||||||||||||||||||||||
| design of the interface for safety-related communication | without | |||||||||||||||||||||||||
| Enclosure | ||||||||||||||||||||||||||
| design of the housing | block, narrow | |||||||||||||||||||||||||
| material of the enclosure | plastic | |||||||||||||||||||||||||
| coating of the enclosure | Other types | |||||||||||||||||||||||||
| design of the housing according to standard | Yes | |||||||||||||||||||||||||
| Drive Head | ||||||||||||||||||||||||||
| design of the actuating element | without | |||||||||||||||||||||||||
| design of the switching function | positive opening | |||||||||||||||||||||||||
| circuit principle | slow-action contacts | |||||||||||||||||||||||||
| number of switching contacts safety-related | 2 | |||||||||||||||||||||||||
| Connections/ Terminals | ||||||||||||||||||||||||||
| type of electrical connection | screw-type terminals | |||||||||||||||||||||||||
| type of connectable conductor cross-sections | ||||||||||||||||||||||||||
| ● solid | 1x (0.5 ... 1.5 mm²), 2x (0.5 ... 0.75 mm²) | |||||||||||||||||||||||||
| ● finely stranded with core end processing | 1x (0.5 ... 1.5 mm²), 2x (0.5 ... 0.75 mm²) | |||||||||||||||||||||||||
| ● at AWG cables solid | 1x (20 ... 16), 2x (20 ... 18) | |||||||||||||||||||||||||
| ● at AWG cables stranded | 1x (20 ... 16), 2x (20 ... 18) | |||||||||||||||||||||||||
| Safety related data | ||||||||||||||||||||||||||
| B10 value with high demand rate according to SN 31920 | 1 000 000 | |||||||||||||||||||||||||
| proportion of dangerous failures with high demand rate according to SN 31920 | 20 % | |||||||||||||||||||||||||
| cable entry type | 1x (M20 x 1.5) | |||||||||||||||||||||||||
| Communication/ Protocol | ||||||||||||||||||||||||||
| design of the interface | without | |||||||||||||||||||||||||
| Ambient conditions | ||||||||||||||||||||||||||
| ambient temperature | ||||||||||||||||||||||||||
| ● during operation | -25 ... +60 °C | |||||||||||||||||||||||||
| ● during storage | -40 ... +90 °C | |||||||||||||||||||||||||
| explosion protection category for dust | none | |||||||||||||||||||||||||
| Supply voltage | ||||||||||||||||||||||||||
| type of voltage of the supply voltage of the optional LED display | DC | |||||||||||||||||||||||||
| supply voltage | ||||||||||||||||||||||||||
| ● of LED | 24 V | |||||||||||||||||||||||||
| Installation/ mounting/ dimensions | ||||||||||||||||||||||||||
| mounting position | any | |||||||||||||||||||||||||
| fastening method | screw fixing | |||||||||||||||||||||||||
| Certificates/ approvals | ||||||||||||||||||||||||||
Downloads and manuals | ||||||||||||||||||||||||||
| ||||||||||||||||||||||||||
| Further information | ||||||||||||||||||||||||||
Information- and Downloadcenter (Catalogs, Brochures,…) | ||||||||||||||||||||||||||
Industry Mall (Online ordering system) | ||||||||||||||||||||||||||
Cax online generator | ||||||||||||||||||||||||||
Service&Support (Manuals, Certificates, Characteristics, FAQs,...) | ||||||||||||||||||||||||||
Image database (product images, 2D dimension drawings, 3D models, device circuit diagrams, EPLAN macros, ...) | ||||||||||||||||||||||||||
| last modified: | 12/21/2020 | |||||||||||||||||||||||||
| Date 5/14/2022 | Subject to change without notice © Copyright Siemens 2022 | |||||||||||||||||||||||||
Additional data
| Product | ||||||||||||||||||||||||||||||||||||||||
| Article Number (Market Facing Number) | 3SE5132-1QV20 | |||||||||||||||||||||||||||||||||||||||
| Product Description | Safety position switch with separate actuator Plastic enclosure 40 mm 1 x (M20 x 1.5) Slow-action contacts 1 NO+2 NC with 2 LEDs yellow/green 24 V DC 5 directions of approaches The matching separate actuator 3SE5000-0AV0. must be ordered separately | |||||||||||||||||||||||||||||||||||||||
| Product family | Enclosure width 40 mm acc. to EN 50041 | |||||||||||||||||||||||||||||||||||||||
| Product Lifecycle (PLM) | PM300:Active Product | |||||||||||||||||||||||||||||||||||||||
| Price data | ||||||||||||||||||||||||||||||||||||||||
| Region Specific PriceGroup / Headquarter Price Group | 41K / 41K | |||||||||||||||||||||||||||||||||||||||
| Surcharge for Raw Materials | None | |||||||||||||||||||||||||||||||||||||||
| Metal Factor | LA------ | |||||||||||||||||||||||||||||||||||||||
| Delivery information | ||||||||||||||||||||||||||||||||||||||||
| Export Control Regulations | AL : N / ECCN : N | |||||||||||||||||||||||||||||||||||||||
| Standard lead time ex-works | 10 Day/Days | |||||||||||||||||||||||||||||||||||||||
| Net Weight (kg) | 0,163 Kg | |||||||||||||||||||||||||||||||||||||||
| Packaging Dimension | 56,00 x 166,50 x 77,50 | |||||||||||||||||||||||||||||||||||||||
| Package size unit of measure | MM | |||||||||||||||||||||||||||||||||||||||
| Quantity Unit | 1 Piece | |||||||||||||||||||||||||||||||||||||||
| Packaging Quantity | 1 | |||||||||||||||||||||||||||||||||||||||
| Additional Product Information | ||||||||||||||||||||||||||||||||||||||||
| EAN | 4011209878129 | |||||||||||||||||||||||||||||||||||||||
| UPC | 804766456824 | |||||||||||||||||||||||||||||||||||||||
| Commodity Code | 85365080 | |||||||||||||||||||||||||||||||||||||||
| LKZ_FDB/ CatalogID | CC-IC10 | |||||||||||||||||||||||||||||||||||||||
| Product Group | 5317 | |||||||||||||||||||||||||||||||||||||||
| Group Code | R711 | |||||||||||||||||||||||||||||||||||||||
| Country of origin | Germany | |||||||||||||||||||||||||||||||||||||||
| Compliance with the substance restrictions according to RoHS directive | Since: 01.07.2006 | |||||||||||||||||||||||||||||||||||||||
| Product class | C: products manufactured / produced to order, which cannot be reused or re-utilised or be returned against credit. | |||||||||||||||||||||||||||||||||||||||
| WEEE (2012/19/EU) Take-Back Obligation | Yes | |||||||||||||||||||||||||||||||||||||||
| REACH Art. 33 Duty to inform according to the current list of candidates |
| |||||||||||||||||||||||||||||||||||||||
| Classifications | ||||||||||||||||||||||||||||||||||||||||
| ||||||||||||||||||||||||||||||||||||||||
ETIM data
ETIM: EC002592 - Position switch with separate actuator
| Value | Unit | |
|---|---|---|
| Degree of protection (NEMA) (EF011959) | - | |
| With status indication (EF001602) | true | |
| Suitable for safety functions (EF001597) | true | |
| Width sensor (EF007094) | 40.0 | mm |
| Height of sensor (EF007283) | 37.8 | mm |
| Length of sensor (EF007334) | 110.0 | mm |
| Forced opening (EF006694) | true | |
| Number of safety auxiliary contacts (EF006940) | 2 | |
| Number of contacts as normally closed contact (EF008255) | 2 | |
| Number of contacts as normally open contact (EF008256) | 1 | |
| Number of contacts as change-over contact (EF008257) | 1 | |
| Type of switching contact (EF003591) | Slow-action switch | |
| Rated operation current Ie at AC-15, 24 V (EF007084) | - | A |
| Rated operation current Ie at AC-15, 125 V (EF007082) | - | A |
| Rated operation current Ie at AC-15, 230 V (EF001385) | - | A |
| Rated operation current Ie at DC-13, 24 V (EF007087) | 3 | A |
| Rated operation current Ie at DC-13, 125 V (EF007085) | - | A |
| Rated operation current Ie at DC-13, 230 V (EF001386) | - | A |
| Construction type housing (EF004008) | Cuboid | |
| Material housing (EF001596) | Plastic | |
| Coating housing (EF001601) | Other | |
| Type of interface (EF006977) | None | |
| Type of interface for safety communication (EF003956) | None | |
| Type of electric connection (EF003961) | Cable entry metrical | |
| Explosion safety category for gas (EF003997) | None | |
| Explosion safety category for dust (EF003998) | None | |
| Ambient temperature during operating (EF007515) | ['-25', '60'] | °C |
| Degree of protection (IP) (EF005474) | IP66/IP67 |