View larger
3SE5115-1BA00-1AF2 SIEMENS Basic switch for position switch 3SE51 Metal enclosure 40 mm according to EN 5004..
3SE5115-1BA00-1AF2
51151
SIEMENS
1 Pcs.
Automation > End switch
Limit Switches and safety relays
Product condition, packaging, certifications and applicable manufacturer warranty terms are confirmed with the quotation.
Request a Quote
Pricing and availability are confirmed for each enquiry. Send this part and we will reply with price and lead time.
Request QuoteProduct Overview
A 3SE5115-1BA00-1AF2 SIEMENS basic switch for position switch serves as a critical electromechanical component for tracking physical movement and part placement in automated systems. These devices provide reliable circuit interruption or activation when triggered by machine components. Pricing, availability and lead time are confirmed per enquiry through an RFQ.
- Width sensor (EF007094): 40.0
- Height of sensor (EF007283): 37.3
- Length of sensor (EF007334): 111.7
- Rated operation current Ie at DC-13, 24 V (EF007087): 3
- Switching function (EF000189): Slow-action switch
- Switching function latching (EF007447): false
- Output electronic (EF006987): FALSE
- Forced opening (EF006694): true
- Number of safety auxiliary contacts (EF006940): 1
- Number of contacts as normally closed contact (EF008255): 1
- Number of contacts as normally open contact (EF008256): 1
- Number of contacts as change-over contact (EF008257): 1
- Construction type housing (EF004008): Cuboid
- Material housing (EF001596): Metal
- Coating housing (EF001601): Lacquered
- Alignment of the control element (EF008793): Roller cam straight
More info
▲ETIM: EC000030 - End switch
| Value | Unit | |
|---|---|---|
| Degree of protection (NEMA) (EF011959) | - | |
| Width sensor (EF007094) | 40.0 | mm |
| Height of sensor (EF007283) | 37.3 | mm |
| Length of sensor (EF007334) | 111.7 | mm |
| Rated operation current Ie at AC-15, 24 V (EF007084) | - | A |
| Rated operation current Ie at AC-15, 125 V (EF007082) | - | A |
| Rated operation current Ie at AC-15, 230 V (EF001385) | - | A |
| Rated operation current Ie at DC-13, 24 V (EF007087) | 3 | A |
| Rated operation current Ie at DC-13, 125 V (EF007085) | - | A |
| Rated operation current Ie at DC-13, 230 V (EF001386) | - | A |
| Switching function (EF000189) | Slow-action switch | |
| Switching function latching (EF007447) | false | |
| Output electronic (EF006987) | FALSE | |
| Forced opening (EF006694) | true | |
| Number of safety auxiliary contacts (EF006940) | 1 | |
| Number of contacts as normally closed contact (EF008255) | 1 | |
| Number of contacts as normally open contact (EF008256) | 1 | |
| Number of contacts as change-over contact (EF008257) | 1 | |
| Type of interface (EF006977) | None | |
| Type of interface for safety communication (EF003956) | None | |
| Construction type housing (EF004008) | Cuboid | |
| Material housing (EF001596) | Metal | |
| Coating housing (EF001601) | Lacquered | |
| Type of control element (EF006976) | None | |
| Alignment of the control element (EF008793) | Roller cam straight | |
| Type of electric connection (EF003961) | Plug-in connection others | |
| With status indication (EF001602) | true | |
| Suitable for safety functions (EF001597) | true | |
| Explosion safety category for gas (EF003997) | None | |
| Explosion safety category for dust (EF003998) | None | |
| Ambient temperature during operating (EF007515) | ['-25', '60'] | °C |
| Degree of protection (IP) (EF005474) | IP65 | |
| Diameter sensor (EF007111) | - | mm |
| Basic switch for position switch 3SE51 Metal enclosure 40 mm according to EN 50041 with connector 6+PE according to EN 43651 with 2 LEDs, yellow/green 24 V DC 1 NO/1 NC slow-action contacts without actuator head Pin assignment: Pin1=21, Pin2=22 Pin3=14 and LED green, Pin4=13 and LED yellow, Pin5=not connected, Pin6=ground LED | ||||||||||||||||||||||||||
| Product brand name | SIRIUS | |||||||||||||||||||||||||
| Product designation | Mechanical position switches | |||||||||||||||||||||||||
| Product type designation | 3SE5 | |||||||||||||||||||||||||
| Manufacturer's article number | ||||||||||||||||||||||||||
| ● of the supplied basic switch | 3SE5115-1BA00-1AF2 | |||||||||||||||||||||||||
| ● of the supplied switching contacts | 3SE5000-0BA00 | |||||||||||||||||||||||||
| Suitability for use safety switch | Yes | |||||||||||||||||||||||||
| General technical data | ||||||||||||||||||||||||||
| Product function | ||||||||||||||||||||||||||
| ● positive opening | Yes | |||||||||||||||||||||||||
| Insulation voltage | ||||||||||||||||||||||||||
| ● rated value | 250 V | |||||||||||||||||||||||||
| Degree of pollution | class 3 | |||||||||||||||||||||||||
| Surge voltage resistance rated value | 0.8 kV | |||||||||||||||||||||||||
| Protection class IP | IP65 | |||||||||||||||||||||||||
| Shock resistance | ||||||||||||||||||||||||||
| ● acc. to IEC 60068-2-27 | 30 g / 11 ms | |||||||||||||||||||||||||
| Vibration resistance | ||||||||||||||||||||||||||
| ● acc. to IEC 60068-2-6 | 0.35 mm/5g | |||||||||||||||||||||||||
| Mechanical service life (switching cycles) | ||||||||||||||||||||||||||
| ● typical | 15 000 000 | |||||||||||||||||||||||||
| Electrical endurance (switching cycles) with contactor 3RH11, 3RT1016, 3RT1017, 3RT1024, 3RT1025, 3RT1026 typical | 10 000 000 | |||||||||||||||||||||||||
| Electrical operating cycles in one hour with contactor 3RH11, 3RT1016, 3RT1017, 3RT1024, 3RT1025, 3RT1026 | 6 000 | |||||||||||||||||||||||||
| Thermal current | 10 A | |||||||||||||||||||||||||
| Reference code acc. to DIN EN 81346-2 | B | |||||||||||||||||||||||||
| Reference code acc. to DIN EN 61346-2 | B | |||||||||||||||||||||||||
| Continuous current of the C characteristic MCB | 1 A; for a short-circuit current smaller than 400 A | |||||||||||||||||||||||||
| Continuous current of the quick DIAZED fuse link | 10 A; for a short-circuit current smaller than 400 A | |||||||||||||||||||||||||
| Continuous current of the DIAZED fuse link gG | 6 A | |||||||||||||||||||||||||
| Active principle | mechanical | |||||||||||||||||||||||||
| Repeat accuracy | 0.05 mm | |||||||||||||||||||||||||
| Minimum actuating force in activation direction | 20 N | |||||||||||||||||||||||||
| Length of the sensor | 111.7 mm | |||||||||||||||||||||||||
| Width of the sensor | 40 mm | |||||||||||||||||||||||||
| Design of the switching contact | mechanical | |||||||||||||||||||||||||
| Number of NC contacts for auxiliary contacts | 1 | |||||||||||||||||||||||||
| Number of NO contacts for auxiliary contacts | 1 | |||||||||||||||||||||||||
| Operating current at DC-13 | ||||||||||||||||||||||||||
| ● at 24 V rated value | 3 A | |||||||||||||||||||||||||
| Design of the interface for safety-related communication | without | |||||||||||||||||||||||||
| Enclosure | ||||||||||||||||||||||||||
| Design of the housing | block, narrow | |||||||||||||||||||||||||
| Material of the enclosure | metal | |||||||||||||||||||||||||
| Coating of the enclosure | cathodic immersion coating | |||||||||||||||||||||||||
| Design of the housing acc. to standard | Yes | |||||||||||||||||||||||||
| Drive Head | ||||||||||||||||||||||||||
| Design of the operating mechanism | Other, without, basic switch with LED and plug | |||||||||||||||||||||||||
| Design of the switching function | Positive opening with appropriate positive opening actuator head | |||||||||||||||||||||||||
| Circuit principle | slow-action contacts | |||||||||||||||||||||||||
| Number of switching contacts safety-related | 1 | |||||||||||||||||||||||||
| Connections/ Terminals | ||||||||||||||||||||||||||
| Type of electrical connection | plug, 6-pole + PU, according to EN 43651 | |||||||||||||||||||||||||
| Cable entry type | plug, 6-pole + PU, according to EN 43651 | |||||||||||||||||||||||||
| Design of plug-in connection | plug, 6-pole + PU: Pin 1 = terminal 21, Pin 2 = 22, Pin 3 = 13/LED green, Pin 4 = 14/LED yellow, Pin 5 = not assigned, Pin 6 = ground LED, PU connected | |||||||||||||||||||||||||
| Communication/ Protocol | ||||||||||||||||||||||||||
| Design of the interface | without | |||||||||||||||||||||||||
| Ambient conditions | ||||||||||||||||||||||||||
| Ambient temperature | ||||||||||||||||||||||||||
| ● during operation | -25 ... +60 °C | |||||||||||||||||||||||||
| ● during storage | -40 ... +90 °C | |||||||||||||||||||||||||
| Explosion protection category for dust | none | |||||||||||||||||||||||||
| Supply voltage | ||||||||||||||||||||||||||
| Type of voltage of the supply voltage | ||||||||||||||||||||||||||
| ● of the optional LED indicator | DC | |||||||||||||||||||||||||
| Supply voltage | ||||||||||||||||||||||||||
| ● of LED | 24 V | |||||||||||||||||||||||||
| Installation/ mounting/ dimensions | ||||||||||||||||||||||||||
| Mounting position | any | |||||||||||||||||||||||||
| Mounting type | screw fixing | |||||||||||||||||||||||||
| Certificates/ approvals | ||||||||||||||||||||||||||
| ||||||||||||||||||||||||||
| Further information | ||||||||||||||||||||||||||
Information- and Downloadcenter (Catalogs, Brochures,…) | ||||||||||||||||||||||||||
Industry Mall (Online ordering system) | ||||||||||||||||||||||||||
Cax online generator | ||||||||||||||||||||||||||
Service&Support (Manuals, Certificates, Characteristics, FAQs,...) | ||||||||||||||||||||||||||
Image database (product images, 2D dimension drawings, 3D models, device circuit diagrams, EPLAN macros, ...) | ||||||||||||||||||||||||||
| last modified: | 08/05/2020 | |||||||||||||||||||||||||
| Product | ||
| Article Number (Market Facing Number) | 3SE5115-1BA00-1AF2 | |
| Product Description | Basic switch for position switch 3SE51 Metal enclosure 40 mm according to EN 50041 with connector 6+PE according to EN 43651 with 2 LEDs, yellow/green 24 V DC 1 NO/1 NC slow-action contacts without actuator head Pin assignment: Pin1=21, Pin2=22 Pin3=14 and LED green, Pin4=13 and LED yellow, Pin5=not connected, Pin6=ground LED | |
| Product family | Not available | |
| Product Lifecycle (PLM) | PM410:Product cancellation | |
| PLM Effective Date | Product is cancelled since: 28.02.2020 | |
| Price data | ||
| Price Group | 41K | |
| Surcharge for Raw Materials | None | |
| Metal Factor | LA------ | |
| Delivery information | ||
| Export Control Regulations | ECCN : N / AL : N | |
| Standard lead time ex-works | 5 Day/Days | |
| Net Weight (kg) | 0,333 Kg | |
| Product Dimensions (W x L x H) | Not available | |
| Packaging Dimension | 50,00 x 58,00 x 109,00 | |
| Package size unit of measure | MM | |
| Quantity Unit | 1 Piece | |
| Packaging Quantity | 1 | |
| Additional Product Information | ||
| EAN | 4011209692909 | |
| UPC | 754554954462 | |
| Commodity Code | 85365080 | |
| LKZ_FDB/ CatalogID | CC-IC10 | |
| Product Group | 5317 | |
| Group Code | R711 | |
| Country of origin | Germany | |
| Compliance with the substance restrictions according to RoHS directive | Since: 01.07.2006 | |
| Product class | C: products manufactured / produced to order, which cannot be reused or re-utilised or be returned against credit. | |
| WEEE (2012/19/EU) Take-Back Obligation | Yes | |
| REACH Art. 33 Duty to inform according to the current list of candidates |
| |
| Classifications | ||
| Not available | ||