View larger
3SE5115-0KA00-1AD1 SIEMENS Basic switch for position switch 3SE51 Metal enclosure 40 mm according to EN 5004..
3SE5115-0KA00-1AD1
51150
SIEMENS
1 Pcs.
Automation > End switch
Limit Switches and safety relays
Product condition, packaging, certifications and applicable manufacturer warranty terms are confirmed with the quotation.
Request a Quote
Pricing and availability are confirmed for each enquiry. Send this part and we will reply with price and lead time.
Request QuoteProduct Overview
Siemens 3SE5115-0KA00-1AD1 SIEMENS Basic switch for position switch 3SE51 Metal enclosure 40 mm according to EN 5004.. serves as a core mechanical safety switch component for industrial monitoring systems. These basic switches provide dependable contact switching for safety interlocks, position verification, and emergency stop mechanisms in demanding factory environments. Pricing, availability and lead time are confirmed per enquiry through an RFQ.
- product designation: Mechanical safety switches
- product type designation: 3SE5
- ● of the supplied switching contacts: 3SE5000-0KA00
- suitability for use safety switch: Yes
- General technical data product function positive opening: Yes
- insulation voltage rated value: 250 V
- degree of pollution: class 3
- surge voltage resistance rated value: 2.5 kV
- protection class IP: IP65
- ● according to IEC 60068-2-27: 30g / 11 ms
- vibration resistance according to IEC 60068-2-6: 0.35 mm/5g
- mechanical service life (switching cycles) typical: 15 000 000
- thermal current: 10 A
- reference code according to IEC 81346-2: B
- continuous current of the C characteristic MCB: 1 A
- for a short-circuit current smaller than: 400 A
- continuous current of the quick DIAZED fuse link: 10 A
More info
▲Technical data
| Basic switch for position switch 3SE51 Metal enclosure 40 mm according to EN 50041 1 NO/2 NC slow-action contacts with connector 6+PE according to EN 43651 plastic, max. 250 V, 6 A without actuator head Pin assignment: Pin1=21, Pin2=22 Pin3=13, Pin4=14, Pin5=31 Pin6=32 and PE connected | ||||||||||||||||||||||||||
| product brand name | SIRIUS | |||||||||||||||||||||||||
| product designation | Mechanical safety switches | |||||||||||||||||||||||||
| product type designation | 3SE5 | |||||||||||||||||||||||||
| manufacturer's article number | ||||||||||||||||||||||||||
| ● of the supplied switching contacts | 3SE5000-0KA00 | |||||||||||||||||||||||||
| suitability for use safety switch | Yes | |||||||||||||||||||||||||
| General technical data | ||||||||||||||||||||||||||
| product function positive opening | Yes | |||||||||||||||||||||||||
| insulation voltage rated value | 250 V | |||||||||||||||||||||||||
| degree of pollution | class 3 | |||||||||||||||||||||||||
| surge voltage resistance rated value | 2.5 kV | |||||||||||||||||||||||||
| protection class IP | IP65 | |||||||||||||||||||||||||
| shock resistance | ||||||||||||||||||||||||||
| ● according to IEC 60068-2-27 | 30g / 11 ms | |||||||||||||||||||||||||
| vibration resistance according to IEC 60068-2-6 | 0.35 mm/5g | |||||||||||||||||||||||||
| mechanical service life (switching cycles) typical | 15 000 000 | |||||||||||||||||||||||||
| electrical endurance (switching cycles) at AC-15 at 230 V typical | 100 000 | |||||||||||||||||||||||||
| electrical endurance (switching cycles) with contactor 3RH11, 3RT1016, 3RT1017, 3RT1024, 3RT1025, 3RT1026 typical | 10 000 000 | |||||||||||||||||||||||||
| Electrical operating cycles in one hour with contactor 3RH11, 3RT1016, 3RT1017, 3RT1024, 3RT1025, 3RT1026 | 6 000 | |||||||||||||||||||||||||
| thermal current | 10 A | |||||||||||||||||||||||||
| reference code according to IEC 81346-2 | B | |||||||||||||||||||||||||
| continuous current of the C characteristic MCB | 1 A; for a short-circuit current smaller than 400 A | |||||||||||||||||||||||||
| continuous current of the quick DIAZED fuse link | 10 A; for a short-circuit current smaller than 400 A | |||||||||||||||||||||||||
| continuous current of the DIAZED fuse link gG | 6 A | |||||||||||||||||||||||||
| active principle | mechanical | |||||||||||||||||||||||||
| repeat accuracy | 0.05 mm | |||||||||||||||||||||||||
| Substance Prohibitance (Date) | 07/01/2006 | |||||||||||||||||||||||||
| minimum actuating force in directions of actuation | 20 N | |||||||||||||||||||||||||
| length of the sensor | 111.7 mm | |||||||||||||||||||||||||
| width of the sensor | 40 mm | |||||||||||||||||||||||||
| design of the switching contact | mechanical | |||||||||||||||||||||||||
| operating frequency rated value | 50 ... 60 Hz | |||||||||||||||||||||||||
| number of NC contacts for auxiliary contacts | 2 | |||||||||||||||||||||||||
| number of NO contacts for auxiliary contacts | 1 | |||||||||||||||||||||||||
| operational current at AC-15 | ||||||||||||||||||||||||||
| ● at 24 V rated value | 6 A | |||||||||||||||||||||||||
| ● at 125 V rated value | 6 A | |||||||||||||||||||||||||
| ● at 240 V rated value | 6 A | |||||||||||||||||||||||||
| operational current at DC-13 | ||||||||||||||||||||||||||
| ● at 24 V rated value | 3 A | |||||||||||||||||||||||||
| ● at 125 V rated value | 0.55 A | |||||||||||||||||||||||||
| ● at 250 V rated value | 0.27 A | |||||||||||||||||||||||||
| design of the interface for safety-related communication | without | |||||||||||||||||||||||||
| Enclosure | ||||||||||||||||||||||||||
| design of the housing | block, narrow | |||||||||||||||||||||||||
| material of the enclosure | metal | |||||||||||||||||||||||||
| coating of the enclosure | cathodic dip coating | |||||||||||||||||||||||||
| design of the housing according to standard | Yes | |||||||||||||||||||||||||
| Drive Head | ||||||||||||||||||||||||||
| design of the actuating element | Other, without, basic switch with plug | |||||||||||||||||||||||||
| design of the switching function | Positive opening with appropriate positive opening actuator head | |||||||||||||||||||||||||
| circuit principle | slow-action contacts | |||||||||||||||||||||||||
| number of switching contacts safety-related | 2 | |||||||||||||||||||||||||
| Connections/ Terminals | ||||||||||||||||||||||||||
| type of electrical connection | plug, 6-pole + PU, according to EN 43651 | |||||||||||||||||||||||||
| cable entry type | plug, 6-pole + PU, according to EN 43651 | |||||||||||||||||||||||||
| design of plug-in connection | plug, 6-pole + PU: Pin 1 = terminal 21, Pin 2 = 22, Pin 3 = 13, Pin 4 = 14, Pin 5 = not assigned, Pin 6 = not assigned, PU connected | |||||||||||||||||||||||||
| Communication/ Protocol | ||||||||||||||||||||||||||
| design of the interface | without | |||||||||||||||||||||||||
| Ambient conditions | ||||||||||||||||||||||||||
| ambient temperature | ||||||||||||||||||||||||||
| ● during operation | -25 ... +85 °C | |||||||||||||||||||||||||
| ● during storage | -40 ... +90 °C | |||||||||||||||||||||||||
| explosion protection category for dust | none | |||||||||||||||||||||||||
| Installation/ mounting/ dimensions | ||||||||||||||||||||||||||
| mounting position | any | |||||||||||||||||||||||||
| fastening method | screw fixing | |||||||||||||||||||||||||
| Certificates/ approvals | ||||||||||||||||||||||||||
Downloads and manuals | ||||||||||||||||||||||||||
| ||||||||||||||||||||||||||
| Further information | ||||||||||||||||||||||||||
Information- and Downloadcenter (Catalogs, Brochures,…) | ||||||||||||||||||||||||||
Industry Mall (Online ordering system) | ||||||||||||||||||||||||||
Cax online generator | ||||||||||||||||||||||||||
Service&Support (Manuals, Certificates, Characteristics, FAQs,...) | ||||||||||||||||||||||||||
Image database (product images, 2D dimension drawings, 3D models, device circuit diagrams, EPLAN macros, ...) | ||||||||||||||||||||||||||
| last modified: | 3/23/2022 | |||||||||||||||||||||||||
| Date 5/4/2022 | Subject to change without notice © Copyright Siemens 2022 | |||||||||||||||||||||||||
Additional data
| Product | ||||||||||||||||||||||||||||||||||||||||
| Article Number (Market Facing Number) | 3SE5115-0KA00-1AD1 | |||||||||||||||||||||||||||||||||||||||
| Product Description | Basic switch for position switch 3SE51 Metal enclosure 40 mm according to EN 50041 1 NO/2 NC slow-action contacts with connector 6+PE according to EN 43651 plastic, max. 250 V, 6 A without actuator head Pin assignment: Pin1=21, Pin2=22 Pin3=13, Pin4=14, Pin5=31 Pin6=32 and PE connected | |||||||||||||||||||||||||||||||||||||||
| Product family | Enclosure width 40 mm acc. to EN 50041 | |||||||||||||||||||||||||||||||||||||||
| Product Lifecycle (PLM) | PM300:Active Product | |||||||||||||||||||||||||||||||||||||||
| Price data | ||||||||||||||||||||||||||||||||||||||||
| Region Specific PriceGroup / Headquarter Price Group | 41K / 41K | |||||||||||||||||||||||||||||||||||||||
| Surcharge for Raw Materials | None | |||||||||||||||||||||||||||||||||||||||
| Metal Factor | LA------ | |||||||||||||||||||||||||||||||||||||||
| Delivery information | ||||||||||||||||||||||||||||||||||||||||
| Export Control Regulations | AL : N / ECCN : N | |||||||||||||||||||||||||||||||||||||||
| Standard lead time ex-works | 10 Day/Days | |||||||||||||||||||||||||||||||||||||||
| Net Weight (kg) | 0,334 Kg | |||||||||||||||||||||||||||||||||||||||
| Packaging Dimension | 50,00 x 58,00 x 109,00 | |||||||||||||||||||||||||||||||||||||||
| Package size unit of measure | MM | |||||||||||||||||||||||||||||||||||||||
| Quantity Unit | 1 Piece | |||||||||||||||||||||||||||||||||||||||
| Packaging Quantity | 1 | |||||||||||||||||||||||||||||||||||||||
| Additional Product Information | ||||||||||||||||||||||||||||||||||||||||
| EAN | 4011209774896 | |||||||||||||||||||||||||||||||||||||||
| UPC | 754554954448 | |||||||||||||||||||||||||||||||||||||||
| Commodity Code | 85365080 | |||||||||||||||||||||||||||||||||||||||
| LKZ_FDB/ CatalogID | CC-IC10 | |||||||||||||||||||||||||||||||||||||||
| Product Group | 5317 | |||||||||||||||||||||||||||||||||||||||
| Group Code | R711 | |||||||||||||||||||||||||||||||||||||||
| Country of origin | Germany | |||||||||||||||||||||||||||||||||||||||
| Compliance with the substance restrictions according to RoHS directive | Since: 01.07.2006 | |||||||||||||||||||||||||||||||||||||||
| Product class | C: products manufactured / produced to order, which cannot be reused or re-utilised or be returned against credit. | |||||||||||||||||||||||||||||||||||||||
| WEEE (2012/19/EU) Take-Back Obligation | Yes | |||||||||||||||||||||||||||||||||||||||
| REACH Art. 33 Duty to inform according to the current list of candidates |
| |||||||||||||||||||||||||||||||||||||||
| Classifications | ||||||||||||||||||||||||||||||||||||||||
| ||||||||||||||||||||||||||||||||||||||||
ETIM data
ETIM: EC000030 - End switch
| Value | Unit | |
|---|---|---|
| Degree of protection (NEMA) (EF011959) | - | |
| Width sensor (EF007094) | 40.0 | mm |
| Height of sensor (EF007283) | 37.3 | mm |
| Length of sensor (EF007334) | 111.7 | mm |
| Rated operation current Ie at AC-15, 24 V (EF007084) | 6 | A |
| Rated operation current Ie at AC-15, 125 V (EF007082) | 6 | A |
| Rated operation current Ie at AC-15, 230 V (EF001385) | - | A |
| Rated operation current Ie at DC-13, 24 V (EF007087) | 3 | A |
| Rated operation current Ie at DC-13, 125 V (EF007085) | 0.55 | A |
| Rated operation current Ie at DC-13, 230 V (EF001386) | - | A |
| Switching function (EF000189) | Slow-action switch | |
| Switching function latching (EF007447) | false | |
| Output electronic (EF006987) | FALSE | |
| Forced opening (EF006694) | true | |
| Number of safety auxiliary contacts (EF006940) | 2 | |
| Number of contacts as normally closed contact (EF008255) | 2 | |
| Number of contacts as normally open contact (EF008256) | 1 | |
| Number of contacts as change-over contact (EF008257) | 1 | |
| Type of interface (EF006977) | None | |
| Type of interface for safety communication (EF003956) | None | |
| Construction type housing (EF004008) | Cuboid | |
| Material housing (EF001596) | Metal | |
| Coating housing (EF001601) | Lacquered | |
| Type of control element (EF006976) | None | |
| Alignment of the control element (EF008793) | Roller cam straight | |
| Type of electric connection (EF003961) | Plug-in connection others | |
| With status indication (EF001602) | false | |
| Suitable for safety functions (EF001597) | true | |
| Explosion safety category for gas (EF003997) | None | |
| Explosion safety category for dust (EF003998) | None | |
| Ambient temperature during operating (EF007515) | ['-25', '85'] | °C |
| Degree of protection (IP) (EF005474) | IP65 | |
| Diameter sensor (EF007111) | - | mm |