| SIRIUS soft starter Values at 690 V, 40 °C standard: 1076 A, 1100 kW Inside-delta: only up to 600 V 400-690 V AC, 230 V AC Screw terminals !!! Phased-out product !!! Successor is SIRIUS 3RW5, Preferred successor type is >>3RW5558-6HA16<< |
| General technical data |
| product brand name | | SIRIUS |
| product feature | | |
| ● integrated bypass contact system | | Yes |
| ● thyristors | | Yes |
| product function | | |
| ● intrinsic device protection | | Yes |
| ● motor overload protection | | Yes |
| ● evaluation of thermistor motor protection | | Yes |
| ● external reset | | Yes |
| ● adjustable current limitation | | Yes |
| ● inside-delta circuit | | Yes |
| product component motor brake output | | Yes |
| insulation voltage rated value | V | 690 |
| degree of pollution | | 3, acc. to IEC 60947-4-2 |
| reference code according to EN 61346-2 | | Q |
| reference code according to DIN 40719 extended according to IEC 204-2 according to IEC 750 | | G |
| Power Electronics |
| product designation | | Soft starter |
| operational current | | |
| ● at 40 °C rated value | A | 1 076 |
| ● at 50 °C rated value | A | 970 |
| ● at 60 °C rated value | A | 880 |
| operational current for 3-phase motors at inside-delta circuit | | |
| ● at 40 °C rated value | A | 1 864 |
| ● at 50 °C rated value | A | 1 680 |
| ● at 60 °C rated value | A | 1 524 |
| yielded mechanical performance for 3-phase motors | | |
| ● at 400 V | | |
| — at standard circuit at 40 °C rated value | kW | 630 |
| — at inside-delta circuit at 40 °C rated value | kW | 1 100 |
| ● at 500 V | | |
| — at standard circuit at 40 °C rated value | kW | 800 |
| — at inside-delta circuit at 40 °C rated value | kW | 1 350 |
| ● at 690 V at standard circuit at 40 °C rated value | kW | 1 100 |
| operating frequency rated value | Hz | 50 ... 60 |
| relative negative tolerance of the operating frequency | % | -10 |
| relative positive tolerance of the operating frequency | % | 10 |
| operating voltage at standard circuit rated value | V | 400 ... 690 |
| relative negative tolerance of the operating voltage at standard circuit | % | -15 |
| relative positive tolerance of the operating voltage at standard circuit | % | 10 |
| operating voltage at inside-delta circuit rated value | V | 400 ... 600 |
| relative negative tolerance of the operating voltage at inside-delta circuit | % | -15 |
| relative positive tolerance of the operating voltage at inside-delta circuit | % | 10 |
| minimum load [%] | % | 8 |
| adjustable motor current for motor overload protection minimum rated value | A | 215 |
| continuous operating current [% of Ie] at 40 °C | % | 115 |
| power loss [W] at operational current at 40 °C during operation typical | W | 510 |
| Control circuit/ Control |
| type of voltage of the control supply voltage | | AC |
| control supply voltage frequency 1 rated value | Hz | 50 |
| control supply voltage frequency 2 rated value | Hz | 60 |
| relative negative tolerance of the control supply voltage frequency | % | -10 |
| relative positive tolerance of the control supply voltage frequency | % | 10 |
| control supply voltage 1 at AC | | |
| ● at 50 Hz rated value | V | 230 |
| ● at 60 Hz rated value | V | 230 |
| relative negative tolerance of the control supply voltage at AC at 50 Hz | % | -15 |
| relative positive tolerance of the control supply voltage at AC at 50 Hz | % | 10 |
| relative negative tolerance of the control supply voltage at AC at 60 Hz | % | -15 |
| relative positive tolerance of the control supply voltage at AC at 60 Hz | % | 10 |
| display version for fault signal | | Display |
| Mechanical data |
| width | mm | 575 |
| height | mm | 780 |
| depth | mm | 292 |
| fastening method | | screw fixing |
| mounting position | | with vertical mounting surface +/-90° rotatable, with vertical mounting surface +/- 22.5° tiltable to the front and back |
| required spacing with side-by-side mounting | | |
| ● upwards | mm | 100 |
| ● at the side | mm | 5 |
| ● downwards | mm | 75 |
| wire length maximum | m | 500 |
| number of poles for main current circuit | | 3 |
| Connections/ Terminals |
| type of electrical connection | | |
| ● for main current circuit | | busbar connection |
| ● for auxiliary and control circuit | | screw-type terminals |
| number of NC contacts for auxiliary contacts | | 0 |
| number of NO contacts for auxiliary contacts | | 3 |
| number of CO contacts for auxiliary contacts | | 1 |
| type of connectable conductor cross-sections for DIN cable lug for main contacts | | |
| ● finely stranded | | 50 ... 240 mm² |
| ● stranded | | 70 ... 240 mm² |
| type of connectable conductor cross-sections for auxiliary contacts | | |
| ● solid | | 2x (0.5 ... 2.5 mm²) |
| ● finely stranded with core end processing | | 2x (0.5 ... 1.5 mm²) |
| type of connectable conductor cross-sections at AWG cables | | |
| ● for main contacts | | 2/0 ... 500 kcmil |
| ● for auxiliary contacts | | 2x (20 ... 14) |
| ● for auxiliary contacts finely stranded with core end processing | | 2x (20 ... 16) |
| Ambient conditions |
| installation altitude at height above sea level | m | 5 000 |
| environmental category | | |
| ● during transport according to IEC 60721 | | 2K2, 2C1, 2S1, 2M2 (max. fall height 0.3 m) |
| ● during storage according to IEC 60721 | | 1K6 (only occasional condensation), 1C2 (no salt mist), 1S2 (sand must not get inside the devices), 1M4 |
| ● during operation according to IEC 60721 | | 3K6 (no formation of ice, no condensation), 3C3 (no salt mist), 3S2 (sand must not get into the devices), 3M6 |
| ambient temperature | | |
| ● during operation | °C | 60 |
| ● during storage | °C | -25 ... +80 |
| derating temperature | °C | 40 |
| protection class IP on the front according to IEC 60529 | | IP00 |
| Certificates/ approvals |
|
| UL/CSA ratings |
| yielded mechanical performance [hp] for 3-phase AC motor | | |
| ● at 460/480 V | | |
| — at standard circuit at 50 °C rated value | hp | 850 |
| — at inside-delta circuit at 50 °C rated value | hp | 1 500 |
| ● at 575/600 V | | |
| — at standard circuit at 50 °C rated value | hp | 1 100 |
| — at inside-delta circuit at 50 °C rated value | hp | 1 900 |
Downloads and manuals |
| contact rating of auxiliary contacts according to UL | | B300 / R300 |
| Further information |
Simulation Tool for Soft Starters (STS) |
Information- and Downloadcenter (Catalogs, Brochures,…) |
Industry Mall (Online ordering system) |
Cax online generator |
Service&Support (Manuals, Certificates, Characteristics, FAQs,...) |
Image database (product images, 2D dimension drawings, 3D models, device circuit diagrams, EPLAN macros, ...) |
|
|
| last modified: | 1/16/2022 |
Date 5/6/2022 | Subject to change without notice © Copyright Siemens 2022 |