A Siemens SIRIUS soft starter regulates the voltage supplied to heavy industrial motors during startup sequences, minimizing mechanical stress and protecting power infrastructure from excessive inrush currents. Pricing, availability and lead time are confirmed per enquiry through an RFQ.
- insulation voltage rated value: V
- ● at 40 °C rated value: A
- ● at 50 °C rated value: A
- ● at 60 °C rated value: A
- ● at 40 °C rated value: A
- ● at 50 °C rated value: A
- ● at 60 °C rated value: A
- — at standard circuit at 40 °C rated value: kW
- — at inside-delta circuit at 40 °C rated value: kW
- — at standard circuit at 40 °C rated value: kW
- — at inside-delta circuit at 40 °C rated value: kW
- ● at 690 V at standard circuit at 40 °C rated value: kW
- operating frequency rated value: Hz
- relative negative tolerance of the operating frequency: %
- relative positive tolerance of the operating frequency: %
- operating voltage at standard circuit rated value: V
More info
▲Technical data
Additional data
| Product | |||||||||||||||||||||||||||||||||||||
| Article Number (Market Facing Number) | 3RW4427-1BC46 | ||||||||||||||||||||||||||||||||||||
| Product Description | SIRIUS soft starter Values at 690 V, 40 °C standard: 93 A, 90 kW Inside-delta: only up to 600 V 400-690 V AC, 230 V AC Screw terminals !!! Phased-out product !!! Successor is SIRIUS 3RW5, Preferred successor type is >>3RW5527-1HA16<< | ||||||||||||||||||||||||||||||||||||
| Product family | 3RW44 soft starters | ||||||||||||||||||||||||||||||||||||
| Product Lifecycle (PLM) | PM400:Phase Out Started | ||||||||||||||||||||||||||||||||||||
| PLM Effective Date | Product phase-out since: 01.10.2019 | ||||||||||||||||||||||||||||||||||||
| Notes | Sucessor:Nachfolger ist SIRIUS 3RW5, Präferierte Nachfolgertype ist >>3RW5527-1HA16<< | ||||||||||||||||||||||||||||||||||||
| Price data | |||||||||||||||||||||||||||||||||||||
| Region Specific PriceGroup / Headquarter Price Group | 42H / 42H | ||||||||||||||||||||||||||||||||||||
| Surcharge for Raw Materials | None | ||||||||||||||||||||||||||||||||||||
| Metal Factor | LAO----- | ||||||||||||||||||||||||||||||||||||
| Delivery information | |||||||||||||||||||||||||||||||||||||
| Export Control Regulations | AL : N / ECCN : EAR99 | ||||||||||||||||||||||||||||||||||||
| Standard lead time ex-works | 50 Day/Days | ||||||||||||||||||||||||||||||||||||
| Net Weight (kg) | 6,427 Kg | ||||||||||||||||||||||||||||||||||||
| Packaging Dimension | 310,00 x 392,00 x 314,00 | ||||||||||||||||||||||||||||||||||||
| Package size unit of measure | MM | ||||||||||||||||||||||||||||||||||||
| Quantity Unit | 1 Piece | ||||||||||||||||||||||||||||||||||||
| Packaging Quantity | 1 | ||||||||||||||||||||||||||||||||||||
| Additional Product Information | |||||||||||||||||||||||||||||||||||||
| EAN | 4011209625594 | ||||||||||||||||||||||||||||||||||||
| UPC | Not available | ||||||||||||||||||||||||||||||||||||
| Commodity Code | 85371098 | ||||||||||||||||||||||||||||||||||||
| LKZ_FDB/ CatalogID | CC-IC10 | ||||||||||||||||||||||||||||||||||||
| Product Group | 3728 | ||||||||||||||||||||||||||||||||||||
| Group Code | R711 | ||||||||||||||||||||||||||||||||||||
| Country of origin | Germany | ||||||||||||||||||||||||||||||||||||
| Compliance with the substance restrictions according to RoHS directive | Since: 28.05.2009 | ||||||||||||||||||||||||||||||||||||
| Product class | A: Standard product which is a stock item could be returned within the returns guidelines/period. | ||||||||||||||||||||||||||||||||||||
| WEEE (2012/19/EU) Take-Back Obligation | Yes | ||||||||||||||||||||||||||||||||||||
| REACH Art. 33 Duty to inform according to the current list of candidates |
| ||||||||||||||||||||||||||||||||||||
| Classifications | |||||||||||||||||||||||||||||||||||||
| |||||||||||||||||||||||||||||||||||||
ETIM data
ETIM: EC000640 - Soft starter
| Value | Unit | |
|---|---|---|
| Release class (EF006668) | - | |
| Torque control (EF009215) | - | |
| Degree of protection (NEMA) (EF011959) | - | |
| With display (EF000458) | - | |
| Internal bypass (EF009214) | - | |
| Rated operation current Ie at 40 °C Tu (EF007039) | 93 | A |
| Rated operating voltage Ue (EF002418) | ['400', '690'] | V |
| Rated power three-phase motor, inline, at 400 V (EF007054) | 45.0 | kW |
| Rated power three-phase motor, inside delta, at 400 V (EF007056) | 90.0 | kW |
| Function (EF000030) | Single direction | |
| Rated surrounding temperature without derating (EF007074) | 40 | °C |
| Rated control supply voltage Us at AC 50HZ (EF003978) | ['-', '230'] | V |
| Rated control supply voltage Us at AC 60HZ (EF003979) | ['-', '230'] | V |
| Rated control supply voltage Us at DC (EF003980) | ['-', '-'] | V |
| Voltage type for actuating (EF008242) | AC | |
| Integrated motor overload protection (EF007297) | true | |
| Degree of protection (IP) (EF005474) | IP00 | |
| Rated power three-phase motor, inline, at 230 V (EF007053) | - | kW |
| Rated power three-phase motor, inside delta, at 230 V (EF007055) | - | kW |