SIEMENS 3RW4037-2BB04 3RW4037-2BB04 SIEMENS SIRIUS soft starter S2 63 A, 30 kW/400 V, 40 °C 200-480 V AC, 24 V AC/DC spring-type t.. View larger
Images are for illustrative purposes only. Please refer to data sheet for details

3RW4037-2BB04 SIEMENS SIRIUS soft starter S2 63 A, 30 kW/400 V, 40 °C 200-480 V AC, 24 V AC/DC spring-type t..

3RW4037-2BB04

40372

SIEMENS

1 Pcs.

SIRIUS soft starter S2 63 A, 30 kW/400 V, 40 °C 200-480 V AC, 24 V AC/DC spring-type terminals SIRIUS Electronic starter, soft start and stop, S2 motor protection 200-480 V AC/400V, 40ºC, CLASS10: 63A, 30KW; Vm:24V AC/DC, spring connection.

Automation > Soft starter
SIRIUS soft starter

Product condition, packaging, certifications and applicable manufacturer warranty terms are confirmed with the quotation.

Request a Quote

Pricing and availability are confirmed for each enquiry. Add your required quantity to begin.

No account, online checkout or payment is required.

More info

Technical data

SIRIUS soft starter S2 63 A, 30 kW/400 V, 40 °C 200-480 V AC, 24 V AC/DC spring-type terminals
General technical data
product brand nameSIRIUS
product feature
● integrated bypass contact systemYes
● thyristorsYes
product function
● intrinsic device protectionYes
● motor overload protectionYes
● evaluation of thermistor motor protectionNo
● external resetYes
● adjustable current limitationYes
● inside-delta circuitNo
product component motor brake outputNo
insulation voltage rated valueV600
degree of pollution3, acc. to IEC 60947-4-2
reference code according to EN 61346-2Q
reference code according to DIN 40719 extended according to IEC 204-2 according to IEC 750G
Power Electronics
product designationSoft starter
operational current
● at 40 °C rated valueA63
● at 50 °C rated valueA58
● at 60 °C rated valueA53
yielded mechanical performance for 3-phase motors
● at 230 V
— at standard circuit at 40 °C rated valuekW18.5
● at 400 V
— at standard circuit at 40 °C rated valuekW30
yielded mechanical performance [hp] for 3-phase AC motor at 200/208 V at standard circuit at 50 °C rated valuehp15
operating frequency rated valueHz50 ... 60
relative negative tolerance of the operating frequency%-10
relative positive tolerance of the operating frequency%10
operating voltage at standard circuit rated valueV200 ... 480
relative negative tolerance of the operating voltage at standard circuit%-15
relative positive tolerance of the operating voltage at standard circuit%10
minimum load [%]%20
adjustable motor current for motor overload protection minimum rated valueA26
continuous operating current [% of Ie] at 40 °C%115
power loss [W] at operational current at 40 °C during operation typicalW12
Control circuit/ Control
type of voltage of the control supply voltageAC/DC
control supply voltage frequency 1 rated valueHz50
control supply voltage frequency 2 rated valueHz60
relative negative tolerance of the control supply voltage frequency%-10
relative positive tolerance of the control supply voltage frequency%10
control supply voltage 1 at AC
● at 50 Hz rated valueV24
● at 60 Hz rated valueV24
relative negative tolerance of the control supply voltage at AC at 50 Hz%-20
relative positive tolerance of the control supply voltage at AC at 50 Hz%20
relative negative tolerance of the control supply voltage at AC at 60 Hz%-20
relative positive tolerance of the control supply voltage at AC at 60 Hz%20
control supply voltage 1 at DC rated valueV24
relative negative tolerance of the control supply voltage at DC%-20
relative positive tolerance of the control supply voltage at DC%20
display version for fault signalred
Mechanical data
size of engine control deviceS2
widthmm55
heightmm160
depthmm170
fastening methodscrew and snap-on mounting
mounting positionWith additional fan: With vertical mounting surface +/-90° rotatable, with vertical mounting surface +/- 22.5° tiltable to the front and back Without additional fan: With vertical mounting surface +/-10° rotatable, with vertical mounting surface +/- 10° t
required spacing with side-by-side mounting
● upwardsmm60
● at the sidemm30
● downwardsmm40
wire length maximumm300
number of poles for main current circuit3
Connections/ Terminals
type of electrical connection
● for main current circuitscrew-type terminals
● for auxiliary and control circuitspring-loaded terminals
number of NC contacts for auxiliary contacts0
number of NO contacts for auxiliary contacts2
number of CO contacts for auxiliary contacts1
type of connectable conductor cross-sections for main contacts for box terminal using the front clamping point
● solid2x (1.5 ... 16 mm²)
● finely stranded with core end processing0.75 ... 25 mm²
● stranded0.75 ... 35 mm²
type of connectable conductor cross-sections for main contacts for box terminal using the back clamping point
● solid2x (1.5 ... 16 mm²)
● finely stranded with core end processing1.5 ... 25 mm²
● stranded1.5 ... 35 mm²
type of connectable conductor cross-sections for main contacts for box terminal using both clamping points
● solid2x (1.5 ... 16 mm²)
● finely stranded with core end processing2x (1.5 ... 16 mm²)
● stranded2x (1.5 ... 25 mm²)
type of connectable conductor cross-sections at AWG cables for main contacts for box terminal
● using the back clamping point16 ... 2
● using the front clamping point18 ... 2
● using both clamping points2x (16 ... 2)
type of connectable conductor cross-sections for auxiliary contacts
● solid2x (0.25 ... 2.5 mm²)
● finely stranded with core end processing2x (0.25 ... 1.5 mm²)
type of connectable conductor cross-sections at AWG cables
● for auxiliary contacts2x (24 ... 14)
Ambient conditions
installation altitude at height above sea levelm5 000
environmental category
● during transport according to IEC 607212K2, 2C1, 2S1, 2M2 (max. fall height 0.3 m)
● during storage according to IEC 607211K6 (only occasional condensation), 1C2 (no salt mist), 1S2 (sand must not get inside the devices), 1M4
● during operation according to IEC 607213K6 (no formation of ice, no condensation), 3C3 (no salt mist), 3S2 (sand must not get into the devices), 3M6
ambient temperature
● during operation°C-25 ... +60
● during storage°C-40 ... +80
derating temperature°C40
protection class IP on the front according to IEC 60529IP20
touch protection on the front according to IEC 60529finger-safe, for vertical contact from the front
Certificates/ approvals
General Product ApprovalEMC

CSA

Confirmation

CCC

UL

EAC

RCM

For use in hazardous locationsDeclaration of ConformityTest CertificatesMarine / Shipping

ATEX-EC-Type-Examination-Certificate

EC/EU-Declaration of Conformity

Special Test Certificate

Type Test Certificates/Test Report

LR (Lloyds Register)

PRS / Polski Rejestr Statkow

Marine / ShippingotherRailway

DNV-GL

Confirmation

Confirmation

Vibration and Shock

UL/CSA ratings
yielded mechanical performance [hp] for 3-phase AC motor
● at 220/230 V
— at standard circuit at 50 °C rated valuehp20
● at 460/480 V
— at standard circuit at 50 °C rated valuehp40

Downloads and manuals

contact rating of auxiliary contacts according to ULB300 / R300
Further information
Simulation Tool for Soft Starters (STS)
Information- and Downloadcenter (Catalogs, Brochures,…)
Industry Mall (Online ordering system)
Cax online generator
Service&Support (Manuals, Certificates, Characteristics, FAQs,...)
Image database (product images, 2D dimension drawings, 3D models, device circuit diagrams, EPLAN macros, ...)
last modified:1/16/2022
Date
5/14/2022
Subject to change without notice
© Copyright Siemens 2022


Additional data

Product
Article Number (Market Facing Number)3RW4037-2BB04
Product DescriptionSIRIUS soft starter S2 63 A, 30 kW/400 V, 40 °C 200-480 V AC, 24 V AC/DC spring-type terminals
Product family3RW40 soft starters
Product Lifecycle (PLM)PM300:Active Product
Price data
Region Specific PriceGroup / Headquarter Price Group42G / 42G
Surcharge for Raw MaterialsNone
Metal FactorLAO-----
Delivery information
Export Control RegulationsAL : N / ECCN : EAR99
Standard lead time ex-works50 Day/Days
Net Weight (kg)1,210 Kg
Packaging Dimension169,00 x 197,00 x 68,00
Package size unit of measureMM
Quantity Unit1 Piece
Packaging Quantity1
Additional Product Information
EAN4011209696341
UPC754554958705
Commodity Code85371098
LKZ_FDB/ CatalogIDCC-IC10
Product Group3727
Group CodeR711
Country of originCzech Republic
Compliance with the substance restrictions according to RoHS directiveSince: 01.05.2012
Product classA: Standard product which is a stock item could be returned within the returns guidelines/period.
WEEE (2012/19/EU) Take-Back ObligationYes
REACH Art. 33 Duty to inform according to the current list of candidates

Information obligation imposed by Article 33, REACH Regulation: This product includes one or several articles in which the following substance of the candidate list is contained in concentrations higher than 0,1% weight by weight (w/w):

Lead

Based on the information currently available, we assume that these substances do not pose any risk if the articles are used as intended (including disposal). Please also refer to product documentation.

Information obligation imposed by Article 33, REACH Regulation: This product includes one or several articles in which the following substance of the candidate list is contained in concentrations higher than 0,1% weight by weight (w/w):

Lead monoxide (lead oxide)

Based on the information currently available, we assume that these substances do not pose any risk if the articles are used as intended (including disposal). Please also refer to product documentation.

Information obligation imposed by Article 33, REACH Regulation: This product includes one or several articles in which the following substance of the candidate list is contained in concentrations higher than 0,1% weight by weight (w/w):

Lead titanium zirconium oxide

Based on the information currently available, we assume that these substances do not pose any risk if the articles are used as intended (including disposal). Please also refer to product documentation.

Information obligation imposed by Article 33, REACH Regulation: This product includes one or several articles in which the following substance of the candidate list is contained in concentrations higher than 0,1% weight by weight (w/w):

Perfluorobutane sulfonic acid (PFBS) and its salts

Based on the information currently available, we assume that these substances do not pose any risk if the articles are used as intended (including disposal). Please also refer to product documentation.

Classifications
VersionClassification
eClass627-37-09-07
eClass7.127-37-09-07
eClass827-37-09-07
eClass927-37-09-07
eClass9.127-37-09-07
ETIM5EC000640
ETIM6EC000640
ETIM7EC000640
ETIM8EC000640
IDEA44740
UNSPSC1439-12-15-21
UNSPSC1539-12-15-21

ETIM data

ETIM: EC000640 - Soft starter

Value Unit
Torque control (EF009215) -
Internal bypass (EF009214) -
Degree of protection (NEMA) (EF011959) -
Release class (EF006668) -
With display (EF000458) -
Rated operation current Ie at 40 °C Tu (EF007039) 63A
Rated operating voltage Ue (EF002418) ['200', '480']V
Rated power three-phase motor, inline, at 230 V (EF007053) 18.5kW
Rated power three-phase motor, inline, at 400 V (EF007054) 30.0kW
Function (EF000030) Single direction
Rated surrounding temperature without derating (EF007074) 40°C
Rated control supply voltage Us at AC 50HZ (EF003978) ['-', '24']V
Rated control supply voltage Us at AC 60HZ (EF003979) ['-', '24']V
Rated control supply voltage Us at DC (EF003980) ['-', '24']V
Voltage type for actuating (EF008242) AC/DC
Integrated motor overload protection (EF007297) true
Degree of protection (IP) (EF005474) IP00
Rated power three-phase motor, inside delta, at 230 V (EF007055) -kW
Rated power three-phase motor, inside delta, at 400 V (EF007056) -kW



Product Datasheet

Electrica Online Product Datasheet Prepared from the current product description, catalog data and structured technical attributes.