SIEMENS 3RW3003-1CB54 3RW3003-1CB54 SIEMENS SIRIUS soft starter 22.5mm 3 A, 1.1 kW/400 V, 40 °C 200-400 V AC, 24-230 V AC/DC Screw.. View larger
Images are for illustrative purposes only. Please refer to data sheet for details

3RW3003-1CB54 SIEMENS SIRIUS soft starter 22.5mm 3 A, 1.1 kW/400 V, 40 °C 200-400 V AC, 24-230 V AC/DC Screw..

3RW3003-1CB54

30031

SIEMENS

1 Pcs.

SIRIUS soft starter 22.5mm 3 A, 1.1 kW/400 V, 40 °C 200-400 V AC, 24-230 V AC/DC Screw terminals

Automation > Soft starter
SIRIUS soft starter

Product condition, packaging, certifications and applicable manufacturer warranty terms are confirmed with the quotation.

Request a Quote

Pricing and availability are confirmed for each enquiry. Add your required quantity to begin.

No account, online checkout or payment is required.

More info

Technical data

SIRIUS soft starter 22.5mm 3 A, 1.1 kW/400 V, 40 °C 200-400 V AC, 24-230 V AC/DC Screw terminals
General technical data
product brand nameSIRIUS
product feature
● integrated bypass contact systemNo
● thyristorsYes
product function
● intrinsic device protectionNo
● motor overload protectionNo
● evaluation of thermistor motor protectionNo
● external resetNo
● adjustable current limitationNo
● inside-delta circuitNo
product component motor brake outputNo
insulation voltage rated valueV600
degree of pollution3, acc. to IEC 60947-4-2
reference code according to EN 61346-2Q
reference code according to DIN 40719 extended according to IEC 204-2 according to IEC 750G
Power Electronics
product designationSoft starter
operational current
● at 40 °C rated valueA3
● at 50 °C rated valueA2.6
● at 60 °C rated valueA2.2
yielded mechanical performance for 3-phase motors
● at 230 V
— at standard circuit at 40 °C rated valuekW0.55
● at 400 V
— at standard circuit at 40 °C rated valuekW1.1
yielded mechanical performance [hp] for 3-phase AC motor at 200/208 V at standard circuit at 50 °C rated valuehp0.5
operating frequency rated valueHz50 ... 60
relative negative tolerance of the operating frequency%-10
relative positive tolerance of the operating frequency%10
operating voltage at standard circuit rated valueV200 ... 400
relative negative tolerance of the operating voltage at standard circuit%-10
relative positive tolerance of the operating voltage at standard circuit%10
minimum load [%]%9
continuous operating current [% of Ie] at 40 °C%100
power loss [W] at operational current at 40 °C during operation typicalW6.5
Control circuit/ Control
type of voltage of the control supply voltageAC/DC
control supply voltage frequency 1 rated valueHz50
control supply voltage frequency 2 rated valueHz60
control supply voltage 1 at AC at 50 HzV24 ... 230
control supply voltage 1 at AC at 60 HzV24 ... 230
relative negative tolerance of the control supply voltage at AC at 50 Hz%-10
relative positive tolerance of the control supply voltage at AC at 50 Hz%10
relative negative tolerance of the control supply voltage at AC at 60 Hz%-10
relative positive tolerance of the control supply voltage at AC at 60 Hz%10
control supply voltage 1 at DCV24 ... 230
relative negative tolerance of the control supply voltage at DC%-10
relative positive tolerance of the control supply voltage at DC%10
Mechanical data
widthmm22.5
heightmm102
depthmm123
fastening methodscrew and snap-on mounting
mounting positionWith vertical mounting surface +/-10° rotatable, with vertical mounting surface +/- 10° tiltable to the front and back
wire length maximumm100
number of poles for main current circuit3
Connections/ Terminals
type of electrical connection
● for main current circuitscrew-type terminals
● for auxiliary and control circuitscrew-type terminals
number of NC contacts for auxiliary contacts0
number of NO contacts for auxiliary contacts0
number of CO contacts for auxiliary contacts0
type of connectable conductor cross-sections for main contacts
● solid0.5 ... 4 mm², 2x (0.5 ... 2.5 mm²)
● finely stranded with core end processing0.5 ... 2.5 mm², 2x (0.5 ... 1.5 mm²)
type of connectable conductor cross-sections for auxiliary contacts
● solid0.5 ... 4 mm², 2x (0.5 ... 2.5 mm²)
● finely stranded with core end processing0.5 ... 2.5 mm², 2x (0.5 ... 1.5 mm²)
type of connectable conductor cross-sections at AWG cables
● for main contacts2x (20 ... 14)
● for auxiliary contacts2x (20 ... 14)
Ambient conditions
installation altitude at height above sea levelm5 000
environmental category
● during transport according to IEC 607212K2, 2C1, 2S1, 2M2 (max. fall height 0.3 m)
● during storage according to IEC 607211K6 (only occasional condensation), 1C2 (no salt mist), 1S2 (sand must not get inside the devices), 1M4
● during operation according to IEC 607213K6 (no formation of ice, no condensation), 3C3 (no salt mist), 3S2 (sand must not get into the devices), 3M6
ambient temperature
● during operation°C-25 ... +60
● during storage°C-40 ... +80
derating temperature°C40
protection class IP on the front according to IEC 60529IP20
touch protection on the front according to IEC 60529finger-safe, for vertical contact from the front
Certificates/ approvals
General Product ApprovalEMCDeclaration of Conformity

CSA

Confirmation

UL

EAC

RCM

EC/EU-Declaration of Conformity

Test Certificatesother

Type Test Certificates/Test Report

Special Test Certificate

Confirmation

UL/CSA ratings
yielded mechanical performance [hp] for 3-phase AC motor
● at 220/230 V
— at standard circuit at 50 °C rated valuehp0.5

Downloads and manuals

contact rating of auxiliary contacts according to ULB300 / R300
Further information
Simulation Tool for Soft Starters (STS)
Information- and Downloadcenter (Catalogs, Brochures,…)
Industry Mall (Online ordering system)
Cax online generator
Service&Support (Manuals, Certificates, Characteristics, FAQs,...)
Image database (product images, 2D dimension drawings, 3D models, device circuit diagrams, EPLAN macros, ...)
last modified:1/16/2022
Date
5/6/2022
Subject to change without notice
© Copyright Siemens 2022


Additional data

Product
Article Number (Market Facing Number)3RW3003-1CB54
Product DescriptionSIRIUS soft starter 22.5mm 3 A, 1.1 kW/400 V, 40 °C 200-400 V AC, 24-230 V AC/DC Screw terminals
Product familyOrdering Data Overview
Product Lifecycle (PLM)PM300:Active Product
Price data
Region Specific PriceGroup / Headquarter Price Group42G / 42G
Surcharge for Raw MaterialsNone
Metal FactorLBO-----
Delivery information
Export Control RegulationsAL : N / ECCN : N
Standard lead time ex-works50 Day/Days
Net Weight (kg)0,210 Kg
Packaging Dimension28,00 x 106,50 x 124,00
Package size unit of measureMM
Quantity Unit1 Piece
Packaging Quantity1
Additional Product Information
EAN4011209557802
UPC040892584158
Commodity Code85371098
LKZ_FDB/ CatalogIDCC-IC10
Product Group3718
Group CodeR711
Country of originGermany
Compliance with the substance restrictions according to RoHS directiveSince: 01.05.2012
Product classA: Standard product which is a stock item could be returned within the returns guidelines/period.
WEEE (2012/19/EU) Take-Back ObligationYes
REACH Art. 33 Duty to inform according to the current list of candidates

Information obligation imposed by Article 33, REACH Regulation: This product includes one or several articles in which the following substance of the candidate list is contained in concentrations higher than 0,1% weight by weight (w/w):

Lead titanium zirconium oxide

Based on the information currently available, we assume that these substances do not pose any risk if the articles are used as intended (including disposal). Please also refer to product documentation.

Information obligation imposed by Article 33, REACH Regulation: This product includes one or several articles in which the following substance of the candidate list is contained in concentrations higher than 0,1% weight by weight (w/w):

Lead

Based on the information currently available, we assume that these substances do not pose any risk if the articles are used as intended (including disposal). Please also refer to product documentation.

Information obligation imposed by Article 33, REACH Regulation: This product includes one or several articles in which the following substance of the candidate list is contained in concentrations higher than 0,1% weight by weight (w/w):

Lead monoxide (lead oxide)

Based on the information currently available, we assume that these substances do not pose any risk if the articles are used as intended (including disposal). Please also refer to product documentation.

Classifications
VersionClassification
eClass627-37-09-07
eClass7.127-37-09-07
eClass827-37-09-07
eClass927-37-09-07
eClass9.127-37-09-07
ETIM5EC000640
ETIM6EC000640
ETIM7EC000640
ETIM8EC000640
IDEA44740
UNSPSC1439-12-15-21
UNSPSC1539-12-15-21

ETIM data

ETIM: EC000640 - Soft starter

Value Unit
Torque control (EF009215) -
With display (EF000458) -
Degree of protection (NEMA) (EF011959) -
Internal bypass (EF009214) -
Release class (EF006668) -
Rated operation current Ie at 40 °C Tu (EF007039) 3A
Rated operating voltage Ue (EF002418) ['200', '400']V
Rated power three-phase motor, inline, at 230 V (EF007053) 0.55kW
Rated power three-phase motor, inline, at 400 V (EF007054) 1.1kW
Function (EF000030) Single direction
Rated surrounding temperature without derating (EF007074) 40°C
Rated control supply voltage Us at AC 50HZ (EF003978) ['24', '230']V
Rated control supply voltage Us at AC 60HZ (EF003979) ['24', '230']V
Rated control supply voltage Us at DC (EF003980) ['24', '230']V
Voltage type for actuating (EF008242) AC/DC
Integrated motor overload protection (EF007297) false
Degree of protection (IP) (EF005474) IP20
Rated power three-phase motor, inside delta, at 230 V (EF007055) -kW
Rated power three-phase motor, inside delta, at 400 V (EF007056) -kW



Product Datasheet

Electrica Online Product Datasheet Prepared from the current product description, catalog data and structured technical attributes.