SIEMENS 3RV2902-4DP0 3RV2902-4DP0 SIEMENS Shunt release 210-240 V AC, 50/60 Hz, 100% ON period 190-330 V AC, 50/60 Hz, 5 s ON per.. View larger
Images are for illustrative purposes only. Please refer to data sheet for details

3RV2902-4DP0 SIEMENS Shunt release 210-240 V AC, 50/60 Hz, 100% ON period 190-330 V AC, 50/60 Hz, 5 s ON per..

3RV2902-4DP0

29024

SIEMENS

1 Pcs.

Shunt release 210-240 V AC, 50/60 Hz, 100% ON period 190-330 V AC, 50/60 Hz, 5 s ON period 190-330 V AC, 5 s ON period with ring cable lug connection for circuit breaker 3RV2 SIRIUS Innovations Shutter Release, AC 210...240V, 50/60HZ, 100% ED, AC 190...330V, 50/60HZ, 5SEC ED, DC 190...330V, 5SEC ED, Ring Connection, S00/S0 Switches

Automation > Shunt release (for power circuit breaker)
Motor protection switches

Product condition, packaging, certifications and applicable manufacturer warranty terms are confirmed with the quotation.

Request a Quote

Pricing and availability are confirmed for each enquiry. Add your required quantity to begin.

No account, online checkout or payment is required.

More info

Technical data

Shunt release 210-240 V AC, 50/60 Hz, 100% ON period 190-330 V AC, 50/60 Hz, 5 s ON period 190-330 V AC, 5 s ON period with ring cable lug connection for circuit breaker 3RV2
General technical data
product brand nameSIRIUS
product designationshunt release
size of the circuit-breakerS00, S0, S2, S3
suitability for usemotor circuit breaker
protection class IP on the front according to IEC 60529IP00
touch protection on the front according to IEC 60529finger-safe, for vertical contact from the front
design of short-circuit protectionfuse
degree of pollution3
insulation voltage rated value690 V
insulation voltage with degree of pollution 3 at AC rated value690 V
ambient temperature
● during storage-50 ... +80 °C
● during operation-20 ... +60 °C
reference code according to EN 61346-2F
Auxiliary circuit
number of NC contacts for auxiliary contacts instantaneous contact0
number of NO contacts for auxiliary contacts instantaneous contact0
number of NO contacts for auxiliary contacts leading contact0
number of CO contacts of auxiliary contacts instantaneous contact0
Control circuit/ Control
type of voltage of the control supply voltageAC
control supply voltage frequency
● 1
— initial rated value50 Hz
— final rated value60 Hz
control supply voltage
● 1
— at AC
— at 50 Hz initial rated value210 V
— at 50 Hz final rated value240 V
— at 60 Hz final rated value240 V
— at 60 Hz initial rated value210 V
Installation/ mounting/ dimensions
fastening methodsnap-on mounting
width18.5 mm
height90 mm
depth68 mm
Certificates/ approvals
certificate of suitabilityCE / UL / CSA

Downloads and manuals

General Product ApprovalDeclaration of Conformity

CSA

Confirmation

UL

EAC

UK Declaration of Conformity

EC/EU-Declaration of Conformity

Test CertificatesMarine / Shipping

Type Test Certificates/Test Report

Special Test Certificate

ABS (American Bureau of Shipping)

BV / Bureau Veritas

DNV / Det Norske Veritas

LR (Lloyds Register)

Marine / ShippingotherRailway

PRS / Polski Rejestr Statkow

RINA / Registro Italiano Navale

Confirmation

Household and similar appliances

Vibration and Shock

Further information
Information- and Downloadcenter (Catalogs, Brochures,…)
Industry Mall (Online ordering system)
Cax online generator
Service&Support (Manuals, Certificates, Characteristics, FAQs,...)
Image database (product images, 2D dimension drawings, 3D models, device circuit diagrams, EPLAN macros, ...)
last modified:2/3/2022
Date
5/4/2022
Subject to change without notice
© Copyright Siemens 2022


Additional data

Product
Article Number (Market Facing Number)3RV2902-4DP0
Product DescriptionShunt release 210-240 V AC, 50/60 Hz, 100% ON period 190-330 V AC, 50/60 Hz, 5 s ON period 190-330 V AC, 5 s ON period with ring cable lug connection for circuit breaker 3RV2
Product familyMountable accessories
Product Lifecycle (PLM)PM300:Active Product
Price data
Region Specific PriceGroup / Headquarter Price Group41E / 41E
Surcharge for Raw MaterialsNone
Metal FactorL-P-----
Delivery information
Export Control RegulationsAL : N / ECCN : N
Standard lead time ex-works5 Day/Days
Net Weight (kg)0,130 Kg
Packaging Dimension90,00 x 102,00 x 43,00
Package size unit of measureMM
Quantity Unit1 Piece
Packaging Quantity1
Additional Product Information
EAN4011209824645
UPC662643925050
Commodity Code85364900
LKZ_FDB/ CatalogIDCC-IC10
Product Group5335
Group CodeR711
Country of originCzech Republic
Compliance with the substance restrictions according to RoHS directiveSince: 01.05.2012
Product classA: Standard product which is a stock item could be returned within the returns guidelines/period.
WEEE (2012/19/EU) Take-Back ObligationYes
REACH Art. 33 Duty to inform according to the current list of candidates
There is currently no information on SVHC (Substances of Very High Concern http://echa.europa.eu/web/guest/candidate-list-table) from the supply chain and our established procedures for screening our products for Substances of Very High Concern.We compare our products regularly with the information of the upstream users with regard to the substances indicated in the candidate list in accordance with the requirements of the REACH regulation. As soon as we have new findings, our information will be updated accordingly.
Classifications
VersionClassification
eClass627-37-04-18
eClass7.127-37-04-18
eClass827-37-04-18
eClass927-37-04-18
eClass9.127-37-04-18
ETIM5EC001023
ETIM6EC001023
ETIM7EC001023
ETIM8EC001023
UNSPSC1439-12-15-21
UNSPSC1539-12-15-21

ETIM data

ETIM: EC001023 - Shunt release (for power circuit breaker)

Value Unit
Rated control supply voltage Us at AC 50HZ (EF003978) ['210', '240']V
Rated control supply voltage Us at AC 60HZ (EF003979) ['210', '240']V
Rated control supply voltage Us at DC (EF003980) ['-', '-']V
Voltage type for actuating (EF008242) AC
Initial value of the undelayed short-circuit release - setting range (EF008187) -A
End value adjustment range undelayed short-circuit release (EF008188) -A
Type of electric connection (EF003961) Other
Number of contacts as normally closed contact (EF008255) 0
Number of contacts as change-over contact (EF008257) 0
Suitable for power circuit breaker (EF005863) FALSE
Suitable for off-load switch (EF001543) FALSE
Suitable for motor safety switch (EF005826) FALSE
Suitable for overload relay (EF001545) FALSE
Number of contacts as normally open contact (EF008256) -



Product Datasheet

Electrica Online Product Datasheet Prepared from the current product description, catalog data and structured technical attributes.