View larger
3RV2742-5BD10 SIEMENS Circuit breaker size S3 for system protection with approval circuit breaker UL 489, CS..
3RV2742-5BD10
27425
SIEMENS
1 Pcs.
Automation > Power circuit-breaker for trafo/generator/installation protection
Motor protection switches
Product condition, packaging, certifications and applicable manufacturer warranty terms are confirmed with the quotation.
Request a Quote
Pricing and availability are confirmed for each enquiry. Send this part and we will reply with price and lead time.
Request QuoteProduct Overview
Designed for rigorous system protection, the 3RV2742-5BD10 SIEMENS circuit breaker safeguards industrial machinery and electrical distribution lines against overloads and short circuits. This S3-sized device is engineered to meet strict North American and international safety standards for motor and system protection.
Pricing, availability and lead time are confirmed per enquiry through an RFQ.
- product designation: Circuit breaker
- design of the product: For system protection according to UL 489/CSA C22.2 No. 5
- product type designation: 3RV2
- General technical data size of the circuit-breaker: S3
- size of contactor can be combined company-specific: S3
- product extension auxiliary switch: Yes
- ● at AC in hot operating state: 14 W
- ● at AC in hot operating state per pole: 4.7 W
- surge voltage resistance rated value: 8 kV
- ● between main and auxiliary circuit: 400 V
- ● between main and auxiliary circuit: 400 V
- shock resistance according to IEC 60068-2-27: 25g / 11 ms Sinus
- ● of the main contacts typical: 25 000
- ● of auxiliary contacts typical: 25 000
- electrical endurance (switching cycles) typical: 25 000
- reference code according to IEC 81346-2: Q
More info
▲Technical data
Additional data
| Product | |||||||||||||||||||||||||||||||||||||
| Article Number (Market Facing Number) | 3RV2742-5BD10 | ||||||||||||||||||||||||||||||||||||
| Product Description | Circuit breaker size S3 for system protection with approval circuit breaker UL 489, CSA C22.2 No.5-02 A-release 15 A N-release 225 A screw terminal | ||||||||||||||||||||||||||||||||||||
| Product family | SIRIUS 3RV2 motor starter protectors | ||||||||||||||||||||||||||||||||||||
| Product Lifecycle (PLM) | PM300:Active Product | ||||||||||||||||||||||||||||||||||||
| Price data | |||||||||||||||||||||||||||||||||||||
| Region Specific PriceGroup / Headquarter Price Group | 41E / 41E | ||||||||||||||||||||||||||||||||||||
| Surcharge for Raw Materials | None | ||||||||||||||||||||||||||||||||||||
| Metal Factor | LDP----- | ||||||||||||||||||||||||||||||||||||
| Delivery information | |||||||||||||||||||||||||||||||||||||
| Export Control Regulations | AL : N / ECCN : N | ||||||||||||||||||||||||||||||||||||
| Standard lead time ex-works | 40 Day/Days | ||||||||||||||||||||||||||||||||||||
| Net Weight (kg) | 2,206 Kg | ||||||||||||||||||||||||||||||||||||
| Packaging Dimension | 78,00 x 176,00 x 190,00 | ||||||||||||||||||||||||||||||||||||
| Package size unit of measure | MM | ||||||||||||||||||||||||||||||||||||
| Quantity Unit | 1 Piece | ||||||||||||||||||||||||||||||||||||
| Packaging Quantity | 1 | ||||||||||||||||||||||||||||||||||||
| Additional Product Information | |||||||||||||||||||||||||||||||||||||
| EAN | 4047621014456 | ||||||||||||||||||||||||||||||||||||
| UPC | 804766504365 | ||||||||||||||||||||||||||||||||||||
| Commodity Code | 85362090 | ||||||||||||||||||||||||||||||||||||
| LKZ_FDB/ CatalogID | CC-IC10 | ||||||||||||||||||||||||||||||||||||
| Product Group | 3673 | ||||||||||||||||||||||||||||||||||||
| Group Code | R711 | ||||||||||||||||||||||||||||||||||||
| Country of origin | Germany | ||||||||||||||||||||||||||||||||||||
| Compliance with the substance restrictions according to RoHS directive | Since: 01.03.2017 | ||||||||||||||||||||||||||||||||||||
| Product class | A: Standard product which is a stock item could be returned within the returns guidelines/period. | ||||||||||||||||||||||||||||||||||||
| WEEE (2012/19/EU) Take-Back Obligation | Yes | ||||||||||||||||||||||||||||||||||||
| REACH Art. 33 Duty to inform according to the current list of candidates |
| ||||||||||||||||||||||||||||||||||||
| Classifications | |||||||||||||||||||||||||||||||||||||
| |||||||||||||||||||||||||||||||||||||
ETIM data
ETIM: EC000228 - Power circuit-breaker for trafo/generator/installation protection
| Value | Unit | |
|---|---|---|
| Rated voltage (EF003977) | - | V |
| Complete device with protection unit (EF008906) | - | |
| DIN rail (top hat rail) mounting optional (EF008904) | - | |
| Rated permanent current Iu (EF001389) | 15.0 | A |
| Rated short-circuit breaking capacity lcu at 400 V, 50 Hz (EF007048) | 100.0 | kA |
| Overload release current setting (EF002336) | ['-', '-'] | A |
| Adjustment range short-term delayed short-circuit release (EF007129) | ['-', '-'] | A |
| Adjustment range undelayed short-circuit release (EF007131) | ['225', '225'] | A |
| Integrated earth fault protection (EF007296) | false | |
| Type of electrical connection of main circuit (EF006819) | Screw connection | |
| Device construction (EF008240) | Built-in device fixed built-in technique | |
| Suitable for DIN rail (top hat rail) mounting (EF007250) | FALSE | |
| Number of auxiliary contacts as normally closed contact (EF001377) | - | |
| Number of auxiliary contacts as normally open contact (EF001376) | - | |
| Number of auxiliary contacts as change-over contact (EF003531) | - | |
| With switched-off indicator (EF007006) | false | |
| With under voltage release (EF007518) | false | |
| Number of poles (EF001391) | 3 | |
| Position of connection for main current circuit (EF006671) | Other | |
| Type of control element (EF006976) | Toggle | |
| Motor drive integrated (EF006697) | false | |
| Motor drive optional (EF007386) | false | |
| Degree of protection (IP) (EF005474) | IP20 |






