View larger
3RV2332-4BC10 SIEMENS Circuit breaker size S2 for starter combination Rated current 20 A N-release 260 A scr..
3RV2332-4BC10
23324
SIEMENS
1 Pcs.
Automation > Motor protection circuit-breaker
Motor protection switches
Product condition, packaging, certifications and applicable manufacturer warranty terms are confirmed with the quotation.
Request a Quote
Pricing and availability are confirmed for each enquiry. Send this part and we will reply with price and lead time.
Request QuoteProduct Overview
Siemens 3RV2332-4BC10 size S2 circuit breaker is engineered for integration into industrial motor starter combinations to manage switching tasks and protect equipment. S2 frame size units handle demanding electrical loads within automated manufacturing environments safely.
Pricing, availability and lead time are confirmed per enquiry through an RFQ.
- Product Article Number (Market Facing Number): 3RV2332-4BC10
- Product family: SIRIUS 3RV2 motor starter protectors
- Product Lifecycle (PLM): PM300:Active Product
- Metal Factor: LBP-----
- Delivery information Export Control Regulations: AL : N / ECCN : N
- Standard lead time ex-works: 60 Day/Days
- Net Weight (kg): 1,121 Kg
- Packaging Dimension: 62,00 x 147,00 x 167,00
- Package size unit of measure: MM
- Quantity Unit: 1 Piece
- Packaging Quantity: 1
- Additional Product Information EAN: 4011209944633
- UPC: Not available
- Commodity Code: 85362090
- LKZ_FDB/ CatalogID: CC-IC10
- Product Group: 5334
More info
▲Additional data
| Product | |||||||||||||||||||||||||||||||||||||
| Article Number (Market Facing Number) | 3RV2332-4BC10 | ||||||||||||||||||||||||||||||||||||
| Product Description | Circuit breaker size S2 for starter combination Rated current 20 A N-release 260 A screw terminal increased switching capacity | ||||||||||||||||||||||||||||||||||||
| Product family | SIRIUS 3RV2 motor starter protectors | ||||||||||||||||||||||||||||||||||||
| Product Lifecycle (PLM) | PM300:Active Product | ||||||||||||||||||||||||||||||||||||
| Price data | |||||||||||||||||||||||||||||||||||||
| Region Specific PriceGroup / Headquarter Price Group | 41E / 41E | ||||||||||||||||||||||||||||||||||||
| Surcharge for Raw Materials | None | ||||||||||||||||||||||||||||||||||||
| Metal Factor | LBP----- | ||||||||||||||||||||||||||||||||||||
| Delivery information | |||||||||||||||||||||||||||||||||||||
| Export Control Regulations | AL : N / ECCN : N | ||||||||||||||||||||||||||||||||||||
| Standard lead time ex-works | 60 Day/Days | ||||||||||||||||||||||||||||||||||||
| Net Weight (kg) | 1,121 Kg | ||||||||||||||||||||||||||||||||||||
| Packaging Dimension | 62,00 x 147,00 x 167,00 | ||||||||||||||||||||||||||||||||||||
| Package size unit of measure | MM | ||||||||||||||||||||||||||||||||||||
| Quantity Unit | 1 Piece | ||||||||||||||||||||||||||||||||||||
| Packaging Quantity | 1 | ||||||||||||||||||||||||||||||||||||
| Additional Product Information | |||||||||||||||||||||||||||||||||||||
| EAN | 4011209944633 | ||||||||||||||||||||||||||||||||||||
| UPC | Not available | ||||||||||||||||||||||||||||||||||||
| Commodity Code | 85362090 | ||||||||||||||||||||||||||||||||||||
| LKZ_FDB/ CatalogID | CC-IC10 | ||||||||||||||||||||||||||||||||||||
| Product Group | 5334 | ||||||||||||||||||||||||||||||||||||
| Group Code | R711 | ||||||||||||||||||||||||||||||||||||
| Country of origin | Germany | ||||||||||||||||||||||||||||||||||||
| Compliance with the substance restrictions according to RoHS directive | Since: 15.10.2014 | ||||||||||||||||||||||||||||||||||||
| Product class | A: Standard product which is a stock item could be returned within the returns guidelines/period. | ||||||||||||||||||||||||||||||||||||
| WEEE (2012/19/EU) Take-Back Obligation | Yes | ||||||||||||||||||||||||||||||||||||
| REACH Art. 33 Duty to inform according to the current list of candidates |
| ||||||||||||||||||||||||||||||||||||
| Classifications | |||||||||||||||||||||||||||||||||||||
| |||||||||||||||||||||||||||||||||||||
ETIM data
ETIM: EC000074 - Motor protection circuit-breaker
| Value | Unit | |
|---|---|---|
| Overload release current setting (EF002336) | ['-', '-'] | A |
| Adjustment range undelayed short-circuit release (EF007131) | ['260', '260'] | A |
| With thermal protection (EF006233) | - | |
| Phase failure sensitive (EF007400) | false | |
| Switch off technique (EF007007) | Magnetic | |
| Rated operating voltage (EF001435) | ['690', '690'] | V |
| Rated permanent current Iu (EF001389) | 20.0 | A |
| Rated operation power at AC-3, 230 V (EF007025) | 5.5 | kW |
| Rated operation power at AC-3, 400 V (EF001364) | 7.5 | kW |
| Type of electrical connection of main circuit (EF006819) | Screw connection | |
| Type of control element (EF006976) | Turn button | |
| Device construction (EF008240) | Built-in device fixed built-in technique | |
| With integrated auxiliary switch (EF001387) | false | |
| With integrated under voltage release (EF001390) | false | |
| Number of poles (EF001391) | 3 | |
| Rated short-circuit breaking capacity lcu at 400 V, AC (EF007049) | 100.0 | kA |
| Degree of protection (IP) (EF005474) | IP20 | |
| Height (EF000040) | 140.0 | mm |
| Width (EF000008) | 55.0 | mm |
| Depth (EF000049) | 97.0 | mm |