View larger
3RV2031-4DB10 SIEMENS Circuit breaker size S2 for motor protection, Class 20 A-release 18...25 A N-release 3..
3RV2031-4DB10
20314
SIEMENS
1 Pcs.
Automation > Motor protection circuit-breaker
Motor protection switches
Product condition, packaging, certifications and applicable manufacturer warranty terms are confirmed with the quotation.
Request a Quote
Pricing and availability are confirmed for each enquiry. Send this part and we will reply with price and lead time.
Request QuoteProduct Overview
A Siemens Circuit breaker size S2 for motor protection, Class 20 A-release 18...25 A N-release 3.. functions as an essential protective link in electrical distribution setups, disconnecting power automatically during overcurrent events to safeguard downstream machinery. Industrial installations rely on such circuit breakers to ensure operational safety and prevent equipment damage across diverse automation environments.
Pricing, availability and lead time are confirmed per enquiry through an RFQ.
- product designation: Circuit breaker
- design of the product: For motor protection
- product type designation: 3RV2
- General technical data size of the circuit-breaker: S2
- size of contactor can be combined company-specific: S2
- product extension auxiliary switch: Yes
- ● at AC in hot operating state: 14.5 W
- ● at AC in hot operating state per pole: 4.8 W
- surge voltage resistance rated value: 6 kV
- ● between main and auxiliary circuit: 400 V
- ● between main and auxiliary circuit: 400 V
- shock resistance according to IEC 60068-2-27: 25g / 11 ms Sinus
- ● of the main contacts typical: 50 000
- ● of auxiliary contacts typical: 50 000
- electrical endurance (switching cycles) typical: 50 000
- reference code according to IEC 81346-2: Q
More info
▲Technical data
Additional data
| Product | |||||||||||||||||||||||||||||||||||||
| Article Number (Market Facing Number) | 3RV2031-4DB10 | ||||||||||||||||||||||||||||||||||||
| Product Description | Circuit breaker size S2 for motor protection, Class 20 A-release 18...25 A N-release 325 A Screw terminal Standard switching capacity | ||||||||||||||||||||||||||||||||||||
| Product family | SIRIUS 3RV2 motor starter protectors | ||||||||||||||||||||||||||||||||||||
| Product Lifecycle (PLM) | PM300:Active Product | ||||||||||||||||||||||||||||||||||||
| Price data | |||||||||||||||||||||||||||||||||||||
| Region Specific PriceGroup / Headquarter Price Group | 41E / 41E | ||||||||||||||||||||||||||||||||||||
| Surcharge for Raw Materials | None | ||||||||||||||||||||||||||||||||||||
| Metal Factor | LBP----- | ||||||||||||||||||||||||||||||||||||
| Delivery information | |||||||||||||||||||||||||||||||||||||
| Export Control Regulations | AL : N / ECCN : N | ||||||||||||||||||||||||||||||||||||
| Standard lead time ex-works | 40 Day/Days | ||||||||||||||||||||||||||||||||||||
| Net Weight (kg) | 1,080 Kg | ||||||||||||||||||||||||||||||||||||
| Packaging Dimension | 62,00 x 147,00 x 167,00 | ||||||||||||||||||||||||||||||||||||
| Package size unit of measure | MM | ||||||||||||||||||||||||||||||||||||
| Quantity Unit | 1 Piece | ||||||||||||||||||||||||||||||||||||
| Packaging Quantity | 1 | ||||||||||||||||||||||||||||||||||||
| Additional Product Information | |||||||||||||||||||||||||||||||||||||
| EAN | 4011209930445 | ||||||||||||||||||||||||||||||||||||
| UPC | 887621919900 | ||||||||||||||||||||||||||||||||||||
| Commodity Code | 85362010 | ||||||||||||||||||||||||||||||||||||
| LKZ_FDB/ CatalogID | CC-IC10 | ||||||||||||||||||||||||||||||||||||
| Product Group | 5334 | ||||||||||||||||||||||||||||||||||||
| Group Code | R711 | ||||||||||||||||||||||||||||||||||||
| Country of origin | Germany | ||||||||||||||||||||||||||||||||||||
| Compliance with the substance restrictions according to RoHS directive | Since: 15.10.2014 | ||||||||||||||||||||||||||||||||||||
| Product class | A: Standard product which is a stock item could be returned within the returns guidelines/period. | ||||||||||||||||||||||||||||||||||||
| WEEE (2012/19/EU) Take-Back Obligation | Yes | ||||||||||||||||||||||||||||||||||||
| REACH Art. 33 Duty to inform according to the current list of candidates |
| ||||||||||||||||||||||||||||||||||||
| Classifications | |||||||||||||||||||||||||||||||||||||
| |||||||||||||||||||||||||||||||||||||
ETIM data
ETIM: EC000074 - Motor protection circuit-breaker
| Value | Unit | |
|---|---|---|
| Overload release current setting (EF002336) | ['18', '25'] | A |
| Adjustment range undelayed short-circuit release (EF007131) | ['325', '325'] | A |
| With thermal protection (EF006233) | thermal | |
| Phase failure sensitive (EF007400) | true | |
| Switch off technique (EF007007) | Magnetic | |
| Rated operating voltage (EF001435) | ['690', '690'] | V |
| Rated permanent current Iu (EF001389) | 25.0 | A |
| Rated operation power at AC-3, 230 V (EF007025) | 5.5 | kW |
| Rated operation power at AC-3, 400 V (EF001364) | 11.0 | kW |
| Type of electrical connection of main circuit (EF006819) | Screw connection | |
| Type of control element (EF006976) | Turn button | |
| Device construction (EF008240) | Built-in device fixed built-in technique | |
| With integrated auxiliary switch (EF001387) | false | |
| With integrated under voltage release (EF001390) | false | |
| Number of poles (EF001391) | 3 | |
| Rated short-circuit breaking capacity lcu at 400 V, AC (EF007049) | 65.0 | kA |
| Degree of protection (IP) (EF005474) | IP20 | |
| Height (EF000040) | 140.0 | mm |
| Width (EF000008) | 55.0 | mm |
| Depth (EF000049) | 149.0 | mm |