View larger
3RV2031-4DA10 SIEMENS Circuit breaker size S2 for motor protection, CLASS 10 A-release 18...25 A N-release 3..
3RV2031-4DA10
20314
SIEMENS
1 Pcs.
Automation > Motor protection circuit-breaker
Motor protection switches
Product condition, packaging, certifications and applicable manufacturer warranty terms are confirmed with the quotation.
Request a Quote
Pricing and availability are confirmed for each enquiry. Send this part and we will reply with price and lead time.
Request QuoteProduct Overview
A Siemens circuit breaker size S2 for motor protection, CLASS 10 A-release 18...25 A N-release 3.. (3RV2031-4DA10) is engineered to safeguard industrial machinery against overloads and short circuits. These protective switching devices are commonly installed in motor control panels to automatically interrupt dangerous fault currents and prevent motor burnout. Pricing, availability and lead time are confirmed per enquiry through an RFQ.
- product designation: Circuit breaker
- design of the product: For motor protection
- product type designation: 3RV2
- General technical data size of the circuit-breaker: S2
- size of contactor can be combined company-specific: S2
- product extension auxiliary switch: Yes
- ● at AC in hot operating state: 14.5 W
- ● at AC in hot operating state per pole: 4.8 W
- surge voltage resistance rated value: 6 kV
- ● between main and auxiliary circuit: 400 V
- shock resistance according to IEC 60068-2-27: 25g / 11 ms Sinus
- ● of the main contacts typical: 50 000
- ● of auxiliary contacts typical: 50 000
- electrical endurance (switching cycles) typical: 50 000
- type of protection according to ATEX directive 2014/34/EU: Ex II (2) GD
More info
▲Technical data
Additional data
| Product | |||||||||||||||||||||||||||||||||||||
| Article Number (Market Facing Number) | 3RV2031-4DA10 | ||||||||||||||||||||||||||||||||||||
| Product Description | Circuit breaker size S2 for motor protection, CLASS 10 A-release 18...25 A N-release 325 A Screw terminal Standard switching capacity | ||||||||||||||||||||||||||||||||||||
| Product family | SIRIUS 3RV2 motor starter protectors | ||||||||||||||||||||||||||||||||||||
| Product Lifecycle (PLM) | PM300:Active Product | ||||||||||||||||||||||||||||||||||||
| Price data | |||||||||||||||||||||||||||||||||||||
| Region Specific PriceGroup / Headquarter Price Group | 41E / 41E | ||||||||||||||||||||||||||||||||||||
| Surcharge for Raw Materials | None | ||||||||||||||||||||||||||||||||||||
| Metal Factor | LBP----- | ||||||||||||||||||||||||||||||||||||
| Delivery information | |||||||||||||||||||||||||||||||||||||
| Export Control Regulations | AL : N / ECCN : N | ||||||||||||||||||||||||||||||||||||
| Standard lead time ex-works | 40 Day/Days | ||||||||||||||||||||||||||||||||||||
| Net Weight (kg) | 1,054 Kg | ||||||||||||||||||||||||||||||||||||
| Packaging Dimension | 62,00 x 147,00 x 167,00 | ||||||||||||||||||||||||||||||||||||
| Package size unit of measure | MM | ||||||||||||||||||||||||||||||||||||
| Quantity Unit | 1 Piece | ||||||||||||||||||||||||||||||||||||
| Packaging Quantity | 1 | ||||||||||||||||||||||||||||||||||||
| Additional Product Information | |||||||||||||||||||||||||||||||||||||
| EAN | 4011209930483 | ||||||||||||||||||||||||||||||||||||
| UPC | 887621919887 | ||||||||||||||||||||||||||||||||||||
| Commodity Code | 85362090 | ||||||||||||||||||||||||||||||||||||
| LKZ_FDB/ CatalogID | CC-IC10 | ||||||||||||||||||||||||||||||||||||
| Product Group | 5334 | ||||||||||||||||||||||||||||||||||||
| Group Code | R711 | ||||||||||||||||||||||||||||||||||||
| Country of origin | Germany | ||||||||||||||||||||||||||||||||||||
| Compliance with the substance restrictions according to RoHS directive | Since: 15.10.2014 | ||||||||||||||||||||||||||||||||||||
| Product class | A: Standard product which is a stock item could be returned within the returns guidelines/period. | ||||||||||||||||||||||||||||||||||||
| WEEE (2012/19/EU) Take-Back Obligation | Yes | ||||||||||||||||||||||||||||||||||||
| REACH Art. 33 Duty to inform according to the current list of candidates |
| ||||||||||||||||||||||||||||||||||||
| Classifications | |||||||||||||||||||||||||||||||||||||
| |||||||||||||||||||||||||||||||||||||
ETIM data
ETIM: EC000074 - Motor protection circuit-breaker
| Value | Unit | |
|---|---|---|
| Overload release current setting (EF002336) | ['18', '25'] | A |
| Adjustment range undelayed short-circuit release (EF007131) | ['325', '325'] | A |
| With thermal protection (EF006233) | thermal | |
| Phase failure sensitive (EF007400) | true | |
| Switch off technique (EF007007) | Magnetic | |
| Rated operating voltage (EF001435) | ['690', '690'] | V |
| Rated permanent current Iu (EF001389) | 25.0 | A |
| Rated operation power at AC-3, 230 V (EF007025) | 5.5 | kW |
| Rated operation power at AC-3, 400 V (EF001364) | 11.0 | kW |
| Type of electrical connection of main circuit (EF006819) | Screw connection | |
| Type of control element (EF006976) | Turn button | |
| Device construction (EF008240) | Built-in device fixed built-in technique | |
| With integrated auxiliary switch (EF001387) | false | |
| With integrated under voltage release (EF001390) | false | |
| Number of poles (EF001391) | 3 | |
| Rated short-circuit breaking capacity lcu at 400 V, AC (EF007049) | 65.0 | kA |
| Degree of protection (IP) (EF005474) | IP20 | |
| Height (EF000040) | 140.0 | mm |
| Width (EF000008) | 55.0 | mm |
| Depth (EF000049) | 149.0 | mm |