This Siemens 3RV2021-4NA15 is a circuit breaker sized for size S0 motor protection applications, offering reliable thermal and magnetic tripping performance. SIRIUS series protectors guard against phase losses, overloads, and short circuits in commercial and industrial drive installations. Specific pricing, availability and lead time are confirmed per enquiry through an RFQ.
- product designation: Circuit breaker
- design of the product: For motor protection
- product type designation: 3RV2
- size of the circuit-breaker: S0
- product extension auxiliary switch: Yes
- surge voltage resistance rated value: 6 kV
- shock resistance according to IEC 60068-2-27: 25g / 11 ms
- type of protection according to ATEX directive 2014/34/EU: Ex II (2) GD
More info
▲Technical data
Additional data
| Product | ||||||||||||||||||||||||||||||||||||||||
| Article Number (Market Facing Number) | 3RV2021-4NA15 | |||||||||||||||||||||||||||||||||||||||
| Product Description | Circuit breaker size S0 for motor protection, CLASS 10 A-release 23...28 A N-release 364 A screw terminal Standard switching capacity with transverse auxiliary switches 1 NO+1 NC | |||||||||||||||||||||||||||||||||||||||
| Product family | SIRIUS 3RV2 motor starter protectors | |||||||||||||||||||||||||||||||||||||||
| Product Lifecycle (PLM) | PM300:Active Product | |||||||||||||||||||||||||||||||||||||||
| Price data | ||||||||||||||||||||||||||||||||||||||||
| Region Specific PriceGroup / Headquarter Price Group | 41E / 41E | |||||||||||||||||||||||||||||||||||||||
| Surcharge for Raw Materials | None | |||||||||||||||||||||||||||||||||||||||
| Metal Factor | LBP----- | |||||||||||||||||||||||||||||||||||||||
| Delivery information | ||||||||||||||||||||||||||||||||||||||||
| Export Control Regulations | AL : N / ECCN : N | |||||||||||||||||||||||||||||||||||||||
| Standard lead time ex-works | 70 Day/Days | |||||||||||||||||||||||||||||||||||||||
| Net Weight (kg) | 0,395 Kg | |||||||||||||||||||||||||||||||||||||||
| Packaging Dimension | 49,00 x 102,00 x 102,00 | |||||||||||||||||||||||||||||||||||||||
| Package size unit of measure | MM | |||||||||||||||||||||||||||||||||||||||
| Quantity Unit | 1 Piece | |||||||||||||||||||||||||||||||||||||||
| Packaging Quantity | 1 | |||||||||||||||||||||||||||||||||||||||
| Additional Product Information | ||||||||||||||||||||||||||||||||||||||||
| EAN | 4011209841352 | |||||||||||||||||||||||||||||||||||||||
| UPC | 662643924565 | |||||||||||||||||||||||||||||||||||||||
| Commodity Code | 85362090 | |||||||||||||||||||||||||||||||||||||||
| LKZ_FDB/ CatalogID | CC-IC10 | |||||||||||||||||||||||||||||||||||||||
| Product Group | 5333 | |||||||||||||||||||||||||||||||||||||||
| Group Code | R711 | |||||||||||||||||||||||||||||||||||||||
| Country of origin | Germany | |||||||||||||||||||||||||||||||||||||||
| Compliance with the substance restrictions according to RoHS directive | Since: 01.10.2009 | |||||||||||||||||||||||||||||||||||||||
| Product class | A: Standard product which is a stock item could be returned within the returns guidelines/period. | |||||||||||||||||||||||||||||||||||||||
| WEEE (2012/19/EU) Take-Back Obligation | Yes | |||||||||||||||||||||||||||||||||||||||
| REACH Art. 33 Duty to inform according to the current list of candidates |
| |||||||||||||||||||||||||||||||||||||||
| Classifications | ||||||||||||||||||||||||||||||||||||||||
| ||||||||||||||||||||||||||||||||||||||||
ETIM data
ETIM: EC000074 - Motor protection circuit-breaker
| Value | Unit | |
|---|---|---|
| Overload release current setting (EF002336) | ['23', '28'] | A |
| Adjustment range undelayed short-circuit release (EF007131) | ['364', '364'] | A |
| With thermal protection (EF006233) | thermal | |
| Phase failure sensitive (EF007400) | true | |
| Switch off technique (EF007007) | Magnetic | |
| Rated operating voltage (EF001435) | ['690', '690'] | V |
| Rated permanent current Iu (EF001389) | 28.0 | A |
| Rated operation power at AC-3, 230 V (EF007025) | 7.5 | kW |
| Rated operation power at AC-3, 400 V (EF001364) | 15.0 | kW |
| Type of electrical connection of main circuit (EF006819) | Screw connection | |
| Type of control element (EF006976) | Turn button | |
| Device construction (EF008240) | Built-in device fixed built-in technique | |
| With integrated auxiliary switch (EF001387) | true | |
| With integrated under voltage release (EF001390) | false | |
| Number of poles (EF001391) | 3 | |
| Rated short-circuit breaking capacity lcu at 400 V, AC (EF007049) | 55.0 | kA |
| Degree of protection (IP) (EF005474) | IP20 | |
| Height (EF000040) | 97.0 | mm |
| Width (EF000008) | 45.0 | mm |
| Depth (EF000049) | 97.0 | mm |