View larger
3RV2021-0AA10 SIEMENS Circuit breaker size S0 for motor protection, Class 10 A-release 0.11...0.16 A Short-c..
3RV2021-0AA10
011016
SIEMENS
1 Pcs.
Automation > Motor protection circuit-breaker
Motor protection switches
Product condition, packaging, certifications and applicable manufacturer warranty terms are confirmed with the quotation.
Request a Quote
Pricing and availability are confirmed for each enquiry. Send this part and we will reply with price and lead time.
Request QuoteProduct Overview
Siemens circuit breaker part number 3RV2021-0AA10 provides specialized motor protection with precise Class 10 trip characteristics for industrial drives. These robust devices are deployed inside control cabinets to prevent thermal overload and electrical fault damage.
Pricing, availability and lead time are confirmed per enquiry through an RFQ.
- product designation: Circuit breaker
- design of the product: For motor protection
- product type designation: 3RV2
- General technical data size of the circuit-breaker: S0
- size of contactor can be combined company-specific: S00, S0
- product extension auxiliary switch: Yes
- ● at AC in hot operating state: 5.5 W
- ● at AC in hot operating state per pole: 1.8 W
- surge voltage resistance rated value: 6 kV
- ● between main and auxiliary circuit: 400 V
- ● between main and auxiliary circuit: 400 V
- shock resistance according to IEC 60068-2-27: 25g / 11 ms
- ● of the main contacts typical: 100 000
- ● of auxiliary contacts typical: 100 000
- electrical endurance (switching cycles) typical: 100 000
- type of protection according to ATEX directive 2014/34/EU: Ex II (2) GD
More info
▲Technical data
Additional data
| Product | |||||||||||||||||||||||||||||||||||||
| Article Number (Market Facing Number) | 3RV2021-0AA10 | ||||||||||||||||||||||||||||||||||||
| Product Description | Circuit breaker size S0 for motor protection, Class 10 A-release 0.11...0.16 A Short-circuit release 2.1 A Screw terminal Standard switching capacity | ||||||||||||||||||||||||||||||||||||
| Product family | SIRIUS 3RV2 motor starter protectors | ||||||||||||||||||||||||||||||||||||
| Product Lifecycle (PLM) | PM300:Active Product | ||||||||||||||||||||||||||||||||||||
| Price data | |||||||||||||||||||||||||||||||||||||
| Region Specific PriceGroup / Headquarter Price Group | 41E / 41E | ||||||||||||||||||||||||||||||||||||
| Surcharge for Raw Materials | None | ||||||||||||||||||||||||||||||||||||
| Metal Factor | LBP----- | ||||||||||||||||||||||||||||||||||||
| Delivery information | |||||||||||||||||||||||||||||||||||||
| Export Control Regulations | AL : N / ECCN : N | ||||||||||||||||||||||||||||||||||||
| Standard lead time ex-works | 70 Day/Days | ||||||||||||||||||||||||||||||||||||
| Net Weight (kg) | 0,280 Kg | ||||||||||||||||||||||||||||||||||||
| Packaging Dimension | 57,00 x 102,00 x 104,00 | ||||||||||||||||||||||||||||||||||||
| Package size unit of measure | MM | ||||||||||||||||||||||||||||||||||||
| Quantity Unit | 1 Piece | ||||||||||||||||||||||||||||||||||||
| Packaging Quantity | 1 | ||||||||||||||||||||||||||||||||||||
| Additional Product Information | |||||||||||||||||||||||||||||||||||||
| EAN | 4047621062723 | ||||||||||||||||||||||||||||||||||||
| UPC | 804766806575 | ||||||||||||||||||||||||||||||||||||
| Commodity Code | 85362010 | ||||||||||||||||||||||||||||||||||||
| LKZ_FDB/ CatalogID | CC-IC10 | ||||||||||||||||||||||||||||||||||||
| Product Group | 5333 | ||||||||||||||||||||||||||||||||||||
| Group Code | R711 | ||||||||||||||||||||||||||||||||||||
| Country of origin | Germany | ||||||||||||||||||||||||||||||||||||
| Compliance with the substance restrictions according to RoHS directive | Since: 01.10.2009 | ||||||||||||||||||||||||||||||||||||
| Product class | A: Standard product which is a stock item could be returned within the returns guidelines/period. | ||||||||||||||||||||||||||||||||||||
| WEEE (2012/19/EU) Take-Back Obligation | Yes | ||||||||||||||||||||||||||||||||||||
| REACH Art. 33 Duty to inform according to the current list of candidates |
| ||||||||||||||||||||||||||||||||||||
| Classifications | |||||||||||||||||||||||||||||||||||||
| |||||||||||||||||||||||||||||||||||||
ETIM data
ETIM: EC000074 - Motor protection circuit-breaker
| Value | Unit | |
|---|---|---|
| Type of control element (EF006976) | - | |
| Degree of protection (IP) (EF005474) | - | |
| Type of electrical connection of main circuit (EF006819) | - | |
| Switch off technique (EF007007) | - | |
| Overload release current setting (EF002336) | ['0.11', '0.16'] | A |
| Adjustment range undelayed short-circuit release (EF007131) | ['2.1', '2.1'] | A |
| With thermal protection (EF006233) | thermal | |
| Phase failure sensitive (EF007400) | true | |
| Rated operating voltage (EF001435) | ['690', '690'] | V |
| Rated permanent current Iu (EF001389) | 0.16 | A |
| Rated operation power at AC-3, 230 V (EF007025) | 0.02 | kW |
| Rated operation power at AC-3, 400 V (EF001364) | 0.04 | kW |
| Device construction (EF008240) | Built-in device fixed built-in technique | |
| With integrated auxiliary switch (EF001387) | false | |
| With integrated under voltage release (EF001390) | false | |
| Number of poles (EF001391) | 3 | |
| Rated short-circuit breaking capacity lcu at 400 V, AC (EF007049) | 100.0 | kA |
| Height (EF000040) | 97.0 | mm |
| Width (EF000008) | 45.0 | mm |
| Depth (EF000049) | 97.0 | mm |