View larger
3RV2011-1KA25 SIEMENS Circuit breaker size S00 for motor protection, CLASS 10 A-release 9...12 A N-release 1..
3RV2011-1KA25
20111
SIEMENS
1 Pcs.
Automation > Motor protection circuit-breaker
Motor protection switches
Product condition, packaging, certifications and applicable manufacturer warranty terms are confirmed with the quotation.
Request a Quote
Pricing and availability are confirmed for each enquiry. Send this part and we will reply with price and lead time.
Request QuoteProduct Overview
3RV2011-1KA25 SIEMENS Circuit breaker size S00 for motor protection, CLASS 10 A-release 9...12 A N-release 1.. functions as a motor protection circuit breaker engineered to guard industrial drives against thermal overloads and short circuits.
Pricing, availability and lead time are confirmed per enquiry through an RFQ.
- product designation: Circuit breaker
- design of the product: For motor protection
- product type designation: 3RV2
- General technical data size of the circuit-breaker: S00
- size of contactor can be combined company-specific: S00, S0
- product extension auxiliary switch: Yes
- ● at AC in hot operating state: 9.25 W
- ● at AC in hot operating state per pole: 3.1 W
- surge voltage resistance rated value: 6 kV
- ● between main and auxiliary circuit: 400 V
- ● between main and auxiliary circuit: 400 V
- shock resistance according to IEC 60068-2-27: 25g / 11 ms
- ● of the main contacts typical: 100 000
- ● of auxiliary contacts typical: 100 000
- electrical endurance (switching cycles) typical: 100 000
- type of protection according to ATEX directive 2014/34/EU: Ex II (2) GD
More info
▲Technical data
Additional data
| Product | ||||||||||||||||||||||||||||||||||||||||
| Article Number (Market Facing Number) | 3RV2011-1KA25 | |||||||||||||||||||||||||||||||||||||||
| Product Description | Circuit breaker size S00 for motor protection, CLASS 10 A-release 9...12 A N-release 163 A Spring-type terminal Standard switching capacity with transverse auxiliary switches 1 NO+1 NC | |||||||||||||||||||||||||||||||||||||||
| Product family | SIRIUS 3RV2 motor starter protectors | |||||||||||||||||||||||||||||||||||||||
| Product Lifecycle (PLM) | PM300:Active Product | |||||||||||||||||||||||||||||||||||||||
| Price data | ||||||||||||||||||||||||||||||||||||||||
| Region Specific PriceGroup / Headquarter Price Group | 41E / 41E | |||||||||||||||||||||||||||||||||||||||
| Surcharge for Raw Materials | None | |||||||||||||||||||||||||||||||||||||||
| Metal Factor | LAP----- | |||||||||||||||||||||||||||||||||||||||
| Delivery information | ||||||||||||||||||||||||||||||||||||||||
| Export Control Regulations | AL : N / ECCN : N | |||||||||||||||||||||||||||||||||||||||
| Standard lead time ex-works | 70 Day/Days | |||||||||||||||||||||||||||||||||||||||
| Net Weight (kg) | 0,388 Kg | |||||||||||||||||||||||||||||||||||||||
| Packaging Dimension | 52,50 x 120,00 x 106,50 | |||||||||||||||||||||||||||||||||||||||
| Package size unit of measure | MM | |||||||||||||||||||||||||||||||||||||||
| Quantity Unit | 1 Piece | |||||||||||||||||||||||||||||||||||||||
| Packaging Quantity | 1 | |||||||||||||||||||||||||||||||||||||||
| Additional Product Information | ||||||||||||||||||||||||||||||||||||||||
| EAN | 4011209841215 | |||||||||||||||||||||||||||||||||||||||
| UPC | 662643924206 | |||||||||||||||||||||||||||||||||||||||
| Commodity Code | 85362090 | |||||||||||||||||||||||||||||||||||||||
| LKZ_FDB/ CatalogID | CC-IC10 | |||||||||||||||||||||||||||||||||||||||
| Product Group | 5332 | |||||||||||||||||||||||||||||||||||||||
| Group Code | R711 | |||||||||||||||||||||||||||||||||||||||
| Country of origin | Germany | |||||||||||||||||||||||||||||||||||||||
| Compliance with the substance restrictions according to RoHS directive | Since: 01.10.2009 | |||||||||||||||||||||||||||||||||||||||
| Product class | A: Standard product which is a stock item could be returned within the returns guidelines/period. | |||||||||||||||||||||||||||||||||||||||
| WEEE (2012/19/EU) Take-Back Obligation | Yes | |||||||||||||||||||||||||||||||||||||||
| REACH Art. 33 Duty to inform according to the current list of candidates |
| |||||||||||||||||||||||||||||||||||||||
| Classifications | ||||||||||||||||||||||||||||||||||||||||
| ||||||||||||||||||||||||||||||||||||||||
ETIM data
ETIM: EC000074 - Motor protection circuit-breaker
| Value | Unit | |
|---|---|---|
| Overload release current setting (EF002336) | ['9', '12.5'] | A |
| Adjustment range undelayed short-circuit release (EF007131) | ['163', '163'] | A |
| With thermal protection (EF006233) | thermal | |
| Phase failure sensitive (EF007400) | true | |
| Switch off technique (EF007007) | Magnetic | |
| Rated operating voltage (EF001435) | ['690', '690'] | V |
| Rated permanent current Iu (EF001389) | 12.5 | A |
| Rated operation power at AC-3, 230 V (EF007025) | 3.0 | kW |
| Rated operation power at AC-3, 400 V (EF001364) | 5.5 | kW |
| Type of electrical connection of main circuit (EF006819) | Spring clamp connection | |
| Type of control element (EF006976) | Turn button | |
| Device construction (EF008240) | Built-in device fixed built-in technique | |
| With integrated auxiliary switch (EF001387) | true | |
| With integrated under voltage release (EF001390) | false | |
| Number of poles (EF001391) | 3 | |
| Rated short-circuit breaking capacity lcu at 400 V, AC (EF007049) | 100.0 | kA |
| Degree of protection (IP) (EF005474) | IP20 | |
| Height (EF000040) | 106.0 | mm |
| Width (EF000008) | 45.0 | mm |
| Depth (EF000049) | 97.0 | mm |