View larger
3RV1011-1FA15 SIEMENS Circuit breaker size S00 for motor protection, CLASS 10 A-release 3.5...5 A N release ..
3RV1011-1FA15
10111
SIEMENS
1 Pcs.
Automation > Motor protection circuit-breaker
Motor protection switches
Product condition, packaging, certifications and applicable manufacturer warranty terms are confirmed with the quotation.
Request a Quote
Pricing and availability are confirmed for each enquiry. Send this part and we will reply with price and lead time.
Request QuoteProduct Overview
Engineered for reliable performance, the Siemens 3RV1011-1FA15 circuit breaker offers essential overcurrent and short-circuit protection for mid-range industrial motor loads. Plant operators use these robust protective switches to maintain system stability and safeguard critical machinery.
Pricing, availability and lead time are confirmed per enquiry through an RFQ.
- product designation: Circuit breaker
- design of the product: For motor protection
- product type designation: 3RV1
- General technical data size of the circuit-breaker: S00
- size of contactor can be combined company-specific: S00
- product extension auxiliary switch: Yes
- ● at AC in hot operating state: 7.25 W
- ● at AC in hot operating state per pole: 2.4 W
- surge voltage resistance rated value: 6 kV
- ● between main and auxiliary circuit: 400 V
- ● between main and auxiliary circuit: 400 V
- ● of the main contacts typical: 100 000
- ● of auxiliary contacts typical: 100 000
- electrical endurance (switching cycles) typical: 100 000
- reference code according to IEC 81346-2: Q
- Substance Prohibitance (Date): 01/01/2013
More info
▲Technical data
Additional data
| Product | ||||||||||||||||||||||||||||||||||||||||
| Article Number (Market Facing Number) | 3RV1011-1FA15 | |||||||||||||||||||||||||||||||||||||||
| Product Description | Circuit breaker size S00 for motor protection, CLASS 10 A-release 3.5...5 A N release 65 A 1 NO+1 NC transverse Screw terminal Standard switching capacity | |||||||||||||||||||||||||||||||||||||||
| Product family | SIRIUS 3RV1 motor starter protectors | |||||||||||||||||||||||||||||||||||||||
| Product Lifecycle (PLM) | PM300:Active Product | |||||||||||||||||||||||||||||||||||||||
| Price data | ||||||||||||||||||||||||||||||||||||||||
| Region Specific PriceGroup / Headquarter Price Group | 41E / 41E | |||||||||||||||||||||||||||||||||||||||
| Surcharge for Raw Materials | None | |||||||||||||||||||||||||||||||||||||||
| Metal Factor | LAP----- | |||||||||||||||||||||||||||||||||||||||
| Delivery information | ||||||||||||||||||||||||||||||||||||||||
| Export Control Regulations | AL : N / ECCN : N | |||||||||||||||||||||||||||||||||||||||
| Standard lead time ex-works | 70 Day/Days | |||||||||||||||||||||||||||||||||||||||
| Net Weight (kg) | 0,295 Kg | |||||||||||||||||||||||||||||||||||||||
| Packaging Dimension | 49,00 x 100,00 x 84,00 | |||||||||||||||||||||||||||||||||||||||
| Package size unit of measure | MM | |||||||||||||||||||||||||||||||||||||||
| Quantity Unit | 1 Piece | |||||||||||||||||||||||||||||||||||||||
| Packaging Quantity | 1 | |||||||||||||||||||||||||||||||||||||||
| Additional Product Information | ||||||||||||||||||||||||||||||||||||||||
| EAN | 4011209381827 | |||||||||||||||||||||||||||||||||||||||
| UPC | 040892547610 | |||||||||||||||||||||||||||||||||||||||
| Commodity Code | 85362010 | |||||||||||||||||||||||||||||||||||||||
| LKZ_FDB/ CatalogID | CC-IC10 | |||||||||||||||||||||||||||||||||||||||
| Product Group | 3715 | |||||||||||||||||||||||||||||||||||||||
| Group Code | R711 | |||||||||||||||||||||||||||||||||||||||
| Country of origin | Germany | |||||||||||||||||||||||||||||||||||||||
| Compliance with the substance restrictions according to RoHS directive | Since: 01.01.2013 | |||||||||||||||||||||||||||||||||||||||
| Product class | A: Standard product which is a stock item could be returned within the returns guidelines/period. | |||||||||||||||||||||||||||||||||||||||
| WEEE (2012/19/EU) Take-Back Obligation | Yes | |||||||||||||||||||||||||||||||||||||||
| REACH Art. 33 Duty to inform according to the current list of candidates |
| |||||||||||||||||||||||||||||||||||||||
| Classifications | ||||||||||||||||||||||||||||||||||||||||
| ||||||||||||||||||||||||||||||||||||||||
ETIM data
ETIM: EC000074 - Motor protection circuit-breaker
| Value | Unit | |
|---|---|---|
| Overload release current setting (EF002336) | ['3.5', '5'] | A |
| Adjustment range undelayed short-circuit release (EF007131) | ['65', '65'] | A |
| With thermal protection (EF006233) | thermal | |
| Phase failure sensitive (EF007400) | true | |
| Switch off technique (EF007007) | Magnetic | |
| Rated operating voltage (EF001435) | ['690', '690'] | V |
| Rated permanent current Iu (EF001389) | 5.0 | A |
| Rated operation power at AC-3, 230 V (EF007025) | 1.1 | kW |
| Rated operation power at AC-3, 400 V (EF001364) | 1.5 | kW |
| Type of electrical connection of main circuit (EF006819) | Screw connection | |
| Type of control element (EF006976) | Rocker lever | |
| Device construction (EF008240) | Built-in device fixed built-in technique | |
| With integrated auxiliary switch (EF001387) | true | |
| With integrated under voltage release (EF001390) | false | |
| Number of poles (EF001391) | 3 | |
| Rated short-circuit breaking capacity lcu at 400 V, AC (EF007049) | 100.0 | kA |
| Degree of protection (IP) (EF005474) | IP20 | |
| Height (EF000040) | 90.0 | mm |
| Width (EF000008) | 45.0 | mm |
| Depth (EF000049) | 75.0 | mm |