3RU2116-4AB1 SIEMENS Overload relay 11...16 A Thermal For motor protection Size S00, Class 10 Stand-alone in..
3RU2116-4AB1
21164
SIEMENS
1 Pcs.
Automation > Thermal overload relay
Thermal relays
Product condition, packaging, certifications and applicable manufacturer warranty terms are confirmed with the quotation.
Request a Quote
Pricing and availability are confirmed for each enquiry. Send this part and we will reply with price and lead time.
Request QuoteProduct Overview
Built for reliable thermal management, the Siemens 3RU2116-4AB1 thermal overload relay protects industrial motor applications from harmful overcurrents and phase imbalances. Stand-alone installation flexibility allows technicians to position the relay securely away from the main contactor when panel space requires alternative layouts. Pricing, availability and lead time are confirmed per enquiry through an RFQ.
- product designation: thermal overload relay
- product type designation: 3RU2
- General technical data size of overload relay: S00
- size of contactor can be combined company-specific: S00
- ● per pole: 2.7 W
- surge voltage resistance rated value: 6 kV
- ● between auxiliary and auxiliary circuit: 440 V
- ● between auxiliary and auxiliary circuit: 440 V
- ● between main and auxiliary circuit: 440 V
- ● between main and auxiliary circuit: 440 V
- shock resistance according to IEC 60068-2-27: 8g / 11 ms
- type of protection according to ATEX directive 2014/34/EU: Ex II (2) GD
- reference code according to IEC 81346-2: F
- Substance Prohibitance (Date): 10/01/2009
- ● during operation: -40 ... +70 °C
- ● during storage: -55 ... +80 °C
More info
▲Technical data
Additional data
| Product | ||||||||||||||||||||||||||||||||||||||||
| Article Number (Market Facing Number) | 3RU2116-4AB1 | |||||||||||||||||||||||||||||||||||||||
| Product Description | Overload relay 11...16 A Thermal For motor protection Size S00, Class 10 Stand-alone installation Main circuit: Screw Auxiliary circuit: Screw Manual-Automatic-Reset | |||||||||||||||||||||||||||||||||||||||
| Product family | 3RU2 for standard applications | |||||||||||||||||||||||||||||||||||||||
| Product Lifecycle (PLM) | PM300:Active Product | |||||||||||||||||||||||||||||||||||||||
| Price data | ||||||||||||||||||||||||||||||||||||||||
| Region Specific PriceGroup / Headquarter Price Group | 41F / 41F | |||||||||||||||||||||||||||||||||||||||
| Surcharge for Raw Materials | None | |||||||||||||||||||||||||||||||||||||||
| Metal Factor | L-O----- | |||||||||||||||||||||||||||||||||||||||
| Delivery information | ||||||||||||||||||||||||||||||||||||||||
| Export Control Regulations | AL : N / ECCN : N | |||||||||||||||||||||||||||||||||||||||
| Standard lead time ex-works | 1 Day/Days | |||||||||||||||||||||||||||||||||||||||
| Net Weight (kg) | 0,191 Kg | |||||||||||||||||||||||||||||||||||||||
| Packaging Dimension | 49,00 x 104,00 x 91,00 | |||||||||||||||||||||||||||||||||||||||
| Package size unit of measure | MM | |||||||||||||||||||||||||||||||||||||||
| Quantity Unit | 1 Piece | |||||||||||||||||||||||||||||||||||||||
| Packaging Quantity | 1 | |||||||||||||||||||||||||||||||||||||||
| Additional Product Information | ||||||||||||||||||||||||||||||||||||||||
| EAN | 4011209781900 | |||||||||||||||||||||||||||||||||||||||
| UPC | 662643918915 | |||||||||||||||||||||||||||||||||||||||
| Commodity Code | 85364900 | |||||||||||||||||||||||||||||||||||||||
| LKZ_FDB/ CatalogID | CC-IC10 | |||||||||||||||||||||||||||||||||||||||
| Product Group | 5346 | |||||||||||||||||||||||||||||||||||||||
| Group Code | R711 | |||||||||||||||||||||||||||||||||||||||
| Country of origin | Germany | |||||||||||||||||||||||||||||||||||||||
| Compliance with the substance restrictions according to RoHS directive | Since: 01.10.2009 | |||||||||||||||||||||||||||||||||||||||
| Product class | A: Standard product which is a stock item could be returned within the returns guidelines/period. | |||||||||||||||||||||||||||||||||||||||
| WEEE (2012/19/EU) Take-Back Obligation | Yes | |||||||||||||||||||||||||||||||||||||||
| REACH Art. 33 Duty to inform according to the current list of candidates |
| |||||||||||||||||||||||||||||||||||||||
| Classifications | ||||||||||||||||||||||||||||||||||||||||
| ||||||||||||||||||||||||||||||||||||||||
ETIM data
ETIM: EC000106 - Thermal overload relay
| Value | Unit | |
|---|---|---|
| Reset function input (EF011940) | - | |
| Reset function automatic (EF011941) | - | |
| Reset function push-button (EF011942) | - | |
| Adjustable current range (EF008211) | ['11', '16'] | A |
| Max. rated operation voltage Ue (EF007357) | 690 | V |
| Mounting method (EF000003) | Separate positioning | |
| Type of electrical connection of main circuit (EF006819) | Screw connection | |
| Number of auxiliary contacts as normally closed contact (EF001377) | 1 | |
| Number of auxiliary contacts as normally open contact (EF001376) | 1 | |
| Number of auxiliary contacts as change-over contact (EF003531) | 0 | |
| Release class (EF006668) | CLASS 10 |