Capacitor contactor, AC-6b 20 kVAr, / 400 V 1 NO + 2 NC, 50-60 Hz AC 200-280 V DC 3-pole, Size S0 screw terminal CONTACTOR, AC-6B, 20KVAR/400V, 1NA+2NC, AC(50-60HZ)/DC CONTROL AC/DC 200...280V, 3POL, TAM. S0 SCREW TERMINALS. Manufactured to order. Non-Cancelable Non-Returnable.

Automation > Capacitor contactor
Contactors for switching motors

Product condition, packaging, certifications and applicable manufacturer warranty terms are confirmed with the quotation.

Request a Quote

Pricing and availability are confirmed for each enquiry. Add your required quantity to begin.

No account, online checkout or payment is required.

More info

Technical data

Capacitor contactor, AC-6b 20 kVAr, / 400 V 1 NO + 2 NC, 50-60 Hz AC 200-280 V DC 3-pole, Size S0 screw terminal
product brand nameSIRIUS
product designationcapacitor contactors
product type designation3RT26
General technical data
size of contactorS0
product extension auxiliary switchNo
insulation voltage
● of main circuit with degree of pollution 3 rated value690 V
● of auxiliary circuit with degree of pollution 3 rated value690 V
surge voltage resistance
● of main circuit rated value6 kV
● of auxiliary circuit rated value6 kV
maximum permissible voltage for safe isolation between coil and main contacts according to EN 60947-1400 V
shock resistance at rectangular impulse
● at AC8,3g / 5 ms, 5,3g / 10 ms
● at DC10g / 5 ms, 7,5g / 10 ms
shock resistance with sine pulse
● at AC13,5g / 5 ms, 8,3g / 10 ms
● at DC15g / 5 ms, 10g / 10 ms
mechanical service life (switching cycles)
● of the contactor with added auxiliary switch block typical3 000 000
electrical endurance (switching cycles)200 000
reference code according to IEC 81346-2Q
Substance Prohibitance (Date)05/01/2014
Ambient conditions
installation altitude at height above sea level maximum2 000 m
ambient temperature
● during operation-25 ... +60 °C
● during storage-55 ... +80 °C
relative humidity minimum10 %
relative humidity at 55 °C according to IEC 60068-2-30 maximum95 %
Main circuit
number of NO contacts for main contacts3
number of NC contacts for main contacts0
operational current at AC-6b at 690 V at ambient temperature 60 °C rated value29 A
operating reactive power at AC-6b
● at 230 V at 50/60 Hz at ambient temperature 60 °C rated value4 ... 11.5 kvar
● at 400 V at 50/60 Hz at ambient temperature 60 °C rated value7 ... 20 kvar
● at 500 V at 50/60 Hz at ambient temperature 60 °C rated value8 ... 25 kvar
● at 690 V at 50/60 Hz at ambient temperature 60 °C rated value11 ... 34 kvar
no-load switching frequency
● at AC500 1/h
● at DC500 1/h
operating frequency at AC-6b
● at 230 V maximum100 1/h
● at 240 V maximum100 1/h
● at 400 V maximum100 1/h
● at 480 V maximum100 1/h
● at 500 V maximum100 1/h
● at 600 V maximum100 1/h
● at 690 V maximum100 1/h
Control circuit/ Control
type of voltageAC/DC
type of voltage of the control supply voltageAC/DC
control supply voltage at AC
● at 50 Hz rated value200 ... 280 V
● at 60 Hz rated value200 ... 280 V
control supply voltage frequency
● 1 rated value50 Hz
● 2 rated value60 Hz
control supply voltage at DC
● rated value200 ... 280 V
operating range factor control supply voltage rated value of magnet coil at DC
● initial value0.7
● full-scale value1.3
operating range factor control supply voltage rated value of magnet coil at AC
● at 50 Hz0.7 ... 1.3
● at 60 Hz0.7 ... 1.3
inrush current peak25 A
duration of inrush current peak30 µs
locked-rotor current mean value0.1 A
locked-rotor current peak0.13 A
duration of locked-rotor current180 ms
holding current mean value17 mA
apparent pick-up power of magnet coil at AC14.7 VA
inductive power factor with closing power of the coil0.98
apparent holding power of magnet coil at AC4.3 VA
inductive power factor with the holding power of the coil0.56
closing power of magnet coil at DC14.3 W
holding power of magnet coil at DC1.9 W
closing delay
● at AC50 ... 70 ms
● at DC50 ... 70 ms
opening delay
● at AC30 ... 50 ms
● at DC30 ... 50 ms
arcing time10 ... 10 ms
control version of the switch operating mechanismStandard A1 - A2
residual current of the electronics for control with signal <0>
● at AC at 230 V maximum permissible7 mA
Auxiliary circuit
number of NC contacts for auxiliary contacts2
● attachable0
● instantaneous contact2
number of NO contacts for auxiliary contacts1
● attachable0
● instantaneous contact1
operational current of auxiliary contacts at AC-12 maximum10 A
operational current of auxiliary contacts at AC-15
● at 230 V6 A
● at 400 V3 A
operational current of auxiliary contacts at DC-13
● at 24 V6 A
● at 60 V2 A
● at 110 V1 A
● at 125 V0.9 A
● at 220 V0.3 A
contact reliability of auxiliary contacts0.00000001
UL/CSA ratings
contact rating of auxiliary contacts according to ULA600 / Q600
Short-circuit protection
design of the fuse link
● for short-circuit protection of the main circuit with type of coordination 1 requiredgG: 63 A (690 V, 50 kA)
● for short-circuit protection of the auxiliary switch requiredgG: 10 A (500 V, 1 kA)
Installation/ mounting/ dimensions
mounting position+/-180° rotation possible on vertical mounting surface; can be tilted forward and backward by +/- 22.5° on vertical mounting surface
fastening methodscrew and snap-on mounting onto 35 mm standard mounting rail according to DIN EN 50022
height135 mm
width45 mm
depth165 mm
required spacing
● with side-by-side mounting at the side10 mm
● for grounded parts at the side10 mm
Connections/ Terminals
type of electrical connection
● for main current circuitscrew-type terminals
● for auxiliary and control circuitscrew-type terminals
● at contactor for auxiliary contactsScrew-type terminals
● of magnet coilScrew-type terminals
type of connectable conductor cross-sections
● for main contacts
— solid2x (1 ... 2.5 mm²), 2x (2.5 ... 10 mm²)
— stranded2x (1 ... 2.5 mm²), 2x (2.5 ... 10 mm²)
— solid or stranded2x (1 ... 2.5 mm²), 2x (2.5 ... 10 mm²)
— finely stranded with core end processing2x (1 ... 2.5 mm²), 2x (2.5 ... 6 mm²), 1x 10 mm²
● at AWG cables for main contacts2x (16 ... 12), 2x (14 ... 8)
type of connectable conductor cross-sections
● for auxiliary contacts
— solid2x (0.5 ... 1.5 mm²), 2x (0.75 ... 2.5 mm²), 2x 4 mm²
— solid or stranded2x (0.5 ... 1.5 mm²), 2x (0.75 ... 2.5 mm²), 2x 4 mm²
— finely stranded with core end processing2x (0.5 ... 1.5 mm²), 2x (0.75 ... 2.5 mm²)
● at AWG cables for auxiliary contacts2x (20 ... 16), 2x (18 ... 14), 2x 12
type of minimum connectable cross-section for main contacts at AC-6b
● at 40 °C1x 10 mm²
● at 60 °C2x 10 mm²
AWG number as coded connectable conductor cross section for main contacts16 ... 8
Safety related data
product function
● mirror contact according to IEC 60947-4-1No
● positively driven operation according to IEC 60947-5-1No
protection class IP on the front according to IEC 60529IP20
touch protection on the front according to IEC 60529finger-safe, for vertical contact from the front
Certificates/ approvals

Downloads and manuals

General Product ApprovalEMC

CSA

CCC

Confirmation

UL

EAC

RCM

Declaration of ConformityTest CertificatesMarine / Shippingother

EC/EU-Declaration of Conformity

UK Declaration of Conformity

Type Test Certificates/Test Report

BV / Bureau Veritas

RINA / Registro Italiano Navale

Confirmation

otherDangerous Good

Household and similar appliances

Transport Information

Further information
Information- and Downloadcenter (Catalogs, Brochures,…)
Industry Mall (Online ordering system)
Cax online generator
Service&Support (Manuals, Certificates, Characteristics, FAQs,...)
Image database (product images, 2D dimension drawings, 3D models, device circuit diagrams, EPLAN macros, ...)
Characteristic: Tripping characteristics, I²t, Let-through current
Further characteristics (e.g. electrical endurance, switching frequency)
last modified:12/8/2021
Date
5/14/2022
Subject to change without notice
© Copyright Siemens 2022


Additional data

Product
Article Number (Market Facing Number)3RT2626-1NP35
Product DescriptionCapacitor contactor, AC-6b 20 kVAr, / 400 V 1 NO + 2 NC, 50-60 Hz AC 200-280 V DC 3-pole, Size S0 screw terminal
Product familySIRIUS 3RT26 contactors for capacitive loads (AC-6b), 3-pole
Product Lifecycle (PLM)PM300:Active Product
Price data
Region Specific PriceGroup / Headquarter Price Group41B / 41B
Surcharge for Raw MaterialsNone
Metal FactorLAO-----
Delivery information
Export Control RegulationsAL : N / ECCN : N
Standard lead time ex-works80 Day/Days
Net Weight (kg)0,670 Kg
Packaging Dimension150,00 x 190,00 x 60,00
Package size unit of measureMM
Quantity Unit1 Piece
Packaging Quantity1
Additional Product Information
EAN4011209948112
UPC804766160387
Commodity Code85364900
LKZ_FDB/ CatalogIDCC-IC10
Product Group5336
Group CodeR711
Country of originGermany
Compliance with the substance restrictions according to RoHS directiveSince: 01.05.2014
Product classA: Standard product which is a stock item could be returned within the returns guidelines/period.
WEEE (2012/19/EU) Take-Back ObligationYes
REACH Art. 33 Duty to inform according to the current list of candidates

Information obligation imposed by Article 33, REACH Regulation: This product includes one or several articles in which the following substance of the candidate list is contained in concentrations higher than 0,1% weight by weight (w/w):

Lead

Based on the information currently available, we assume that these substances do not pose any risk if the articles are used as intended (including disposal). Please also refer to product documentation.

Information obligation imposed by Article 33, REACH Regulation: This product includes one or several articles in which the following substance of the candidate list is contained in concentrations higher than 0,1% weight by weight (w/w):

Lead monoxide (lead oxide)

Based on the information currently available, we assume that these substances do not pose any risk if the articles are used as intended (including disposal). Please also refer to product documentation.

Classifications
VersionClassification
eClass627-37-10-06
eClass7.127-37-10-06
eClass827-37-10-06
eClass927-37-10-06
eClass9.127-37-10-06
ETIM5EC001079
ETIM6EC001079
ETIM7EC001079
ETIM8EC001079
IDEA44764
UNSPSC1539-12-15-29

ETIM data

ETIM: EC001079 - Capacitor contactor

Value Unit
Rated control supply voltage Us at AC 50HZ (EF003978) ['200.0', '280.0']V
Rated control supply voltage Us at AC 60HZ (EF003979) ['200.0', '280.0']V
Rated control supply voltage Us at DC (EF003980) ['200', '280']V
Voltage type for actuating (EF008242) AC/DC
Number of auxiliary contacts as normally open contact (EF001376) 1
Number of auxiliary contacts as normally closed contact (EF001377) 2
Type of electrical connection of main circuit (EF006819) Screw connection
Number of main contacts as normally open contact (EF001374) 3
Number of normally closed contacts as main contact (EF001375) 0
Rated blind power at 400 V, 50 Hz (EF007044) 20.0kvar



Product Datasheet