3RT2018-4AP61 SIEMENS Power contactor, AC-3 16 A, 7.5 kW / 400 V 1 NO, 220 V AC, 50 Hz, 240 V 60Hz, 3-pole, ..
3RT2018-4AP61
20184
SIEMENS
1 Pcs.
Automation > Power contactor, AC switching
Contactors for switching motors
Product condition, packaging, certifications and applicable manufacturer warranty terms are confirmed with the quotation.
Request a Quote
Pricing and availability are confirmed for each enquiry. Send this part and we will reply with price and lead time.
Request QuoteProduct Overview
Power contactor, AC-3 16 A, 7.5 kW / 400 V 1 NO, 220 V AC, 50 Hz, 240 V 60Hz, 3-pole 3RT2018-4AP61 from Siemens offers reliable switching performance for mid-range automation tasks. These components are standard fixtures in control panels, providing dependable circuit control for commercial machinery and automated systems.
Pricing, availability and lead time are confirmed per enquiry through an RFQ.
- product brand name: SIRIUS
- Product designation: 3RT2 contactor
- General technical data: Size of contactor: S00
- ● function module for communication: No
- ● Auxiliary switch: Yes
- ● rated value: 690 V
- Degree of pollution: 3
- Surge voltage resistance rated value: 6 kV
- ● between coil and main contacts acc. to EN 60947-1: 400 V
- ● on the front: IP00
- ● of the terminal: IP00
- — at AC: 7,3g / 5 ms, 4,7g / 10 ms
- — at AC: 11,4g / 5 ms, 7,3g / 10 ms
- ● of contactor typical: 30 000 000
- ● of the contactor with added auxiliary switch block typical: 10 000 000
- ● during operation: -25 ... +60 °C
More info
▲| product brand name | SIRIUS | |
| Product designation | 3RT2 contactor | |
| General technical data: | ||
| Size of contactor | S00 | |
| Product extension | ||
| ● function module for communication | No | |
| ● Auxiliary switch | Yes | |
| Insulation voltage | ||
| ● rated value | 690 V | |
| Degree of pollution | 3 | |
| Surge voltage resistance rated value | 6 kV | |
| maximum permissible voltage for safe isolation | ||
| ● between coil and main contacts acc. to EN 60947-1 | 400 V | |
| Protection class IP | ||
| ● on the front | IP00 | |
| ● of the terminal | IP00 | |
| Shock resistance | ||
| ● at rectangular impulse | ||
| — at AC | 7,3g / 5 ms, 4,7g / 10 ms | |
| ● with sine pulse | ||
| — at AC | 11,4g / 5 ms, 7,3g / 10 ms | |
| Mechanical service life (switching cycles) | ||
| ● of contactor typical | 30 000 000 | |
| ● of the contactor with added electronics-compatible auxiliary switch block typical | 5 000 000 | |
| ● of the contactor with added auxiliary switch block typical | 10 000 000 | |
| Ambient conditions: | ||
| Installation altitude at height above sea level maximum | 2 000 m | |
| Ambient temperature | ||
| ● during operation | -25 ... +60 °C | |
| ● during storage | -55 ... +80 °C | |
| Main circuit: | ||
| Number of NO contacts for main contacts | 3 | |
| Number of NC contacts for main contacts | 0 | |
| Operating voltage | ||
| ● at AC-3 rated value maximum | 690 V | |
| Operating current | ||
| ● at AC-1 at 400 V | ||
| — at ambient temperature 40 °C rated value | 22 A | |
| ● at AC-1 | ||
| — up to 690 V at ambient temperature 40 °C rated value | 22 A | |
| — up to 690 V at ambient temperature 60 °C rated value | 20 A | |
| ● at AC-2 at 400 V rated value | 16 A | |
| ● at AC-3 | ||
| — at 400 V rated value | 16 A | |
| — at 500 V rated value | 12.4 A | |
| — at 690 V rated value | 8.9 A | |
| Connectable conductor cross-section in main circuit at AC-1 | ||
| ● at 60 °C minimum permissible | 2.5 mm² | |
| ● at 40 °C minimum permissible | 4 mm² | |
| Operating current for approx. 200000 operating cycles at AC-4 | ||
| ● at 400 V rated value | 5.5 A | |
| ● at 690 V rated value | 4.4 A | |
| Operating current | ||
| ● at 1 current path at DC-1 | ||
| — at 24 V rated value | 20 A | |
| — at 110 V rated value | 2.1 A | |
| — at 220 V rated value | 0.8 A | |
| — at 440 V rated value | 0.6 A | |
| — at 600 V rated value | 0.6 A | |
| ● with 2 current paths in series at DC-1 | ||
| — at 24 V rated value | 20 A | |
| — at 110 V rated value | 12 A | |
| — at 220 V rated value | 1.6 A | |
| — at 440 V rated value | 0.8 A | |
| — at 600 V rated value | 0.7 A | |
| ● with 3 current paths in series at DC-1 | ||
| — at 24 V rated value | 20 A | |
| — at 110 V rated value | 20 A | |
| — at 220 V rated value | 20 A | |
| — at 440 V rated value | 1.3 A | |
| — at 600 V rated value | 1 A | |
| Operating current | ||
| ● at 1 current path at DC-3 at DC-5 | ||
| — at 24 V rated value | 20 A | |
| — at 110 V rated value | 0.1 A | |
| ● with 2 current paths in series at DC-3 at DC-5 | ||
| — at 110 V rated value | 0.35 A | |
| — at 24 V rated value | 20 A | |
| ● with 3 current paths in series at DC-3 at DC-5 | ||
| — at 110 V rated value | 20 A | |
| — at 220 V rated value | 1.5 A | |
| — at 24 V rated value | 20 A | |
| — at 440 V rated value | 0.2 A | |
| — at 600 V rated value | 0.2 A | |
| Operating power | ||
| ● at AC-1 | ||
| — at 230 V rated value | 7.5 kW | |
| — at 230 V at 60 °C rated value | 7.5 kW | |
| — at 400 V rated value | 13 kW | |
| — at 400 V at 60 °C rated value | 13 kW | |
| — at 690 V rated value | 22 kW | |
| — at 690 V at 60 °C rated value | 22 kW | |
| ● at AC-2 at 400 V rated value | 7.5 kW | |
| ● at AC-3 | ||
| — at 230 V rated value | 4 kW | |
| — at 400 V rated value | 7.5 kW | |
| — at 690 V rated value | 7.5 kW | |
| Operating power for approx. 200000 operating cycles at AC-4 | ||
| ● at 400 V rated value | 2.5 kW | |
| ● at 690 V rated value | 3.5 kW | |
| Thermal short-time current limited to 10 s | 128 A | |
| Power loss [W] at AC-3 at 400 V for rated value of the operating current per conductor | 2.2 W | |
| No-load switching frequency | ||
| ● at AC | 10 000 1/h | |
| Operating frequency | ||
| ● at AC-1 maximum | 1 000 1/h | |
| ● at AC-2 maximum | 750 1/h | |
| ● at AC-3 maximum | 750 1/h | |
| ● at AC-4 maximum | 250 1/h | |
| Control circuit/ Control: | ||
| Type of voltage of the control supply voltage | AC | |
| Control supply voltage at AC | ||
| ● at 50 Hz rated value | 220 V | |
| ● at 60 Hz rated value | 240 V | |
| Operating range factor control supply voltage rated value of magnet coil at AC | ||
| ● at 50 Hz | 0.8 ... 1.1 | |
| ● at 60 Hz | 0.85 ... 1.1 | |
| Apparent pick-up power of magnet coil at AC | ||
| ● at 50 Hz | 37 V·A | |
| ● at 60 Hz | 33 V·A | |
| Inductive power factor with closing power of the coil | ||
| ● at 50 Hz | 0.8 | |
| ● at 60 Hz | 0.75 | |
| Apparent holding power of magnet coil at AC | ||
| ● at 50 Hz | 5.7 V·A | |
| ● at 60 Hz | 4.4 V·A | |
| Inductive power factor with the holding power of the coil | ||
| ● at 50 Hz | 0.25 | |
| ● at 60 Hz | 0.25 | |
| Closing delay | ||
| ● at AC | 8 ... 33 ms | |
| Opening delay | ||
| ● at AC | 4 ... 15 ms | |
| Arcing time | 10 ... 15 ms | |
| Residual current of the electronics for control with signal <0> | ||
| ● at AC at 230 V maximum permissible | 4 mA | |
| ● at DC at 24 V maximum permissible | 10 mA | |
| Auxiliary circuit: | ||
| Number of NC contacts | ||
| ● for auxiliary contacts | ||
| — instantaneous contact | 0 | |
| Number of NO contacts | ||
| ● for auxiliary contacts | ||
| — instantaneous contact | 1 | |
| Operating current at AC-12 maximum | 10 A | |
| Operating current at AC-15 | ||
| ● at 230 V rated value | 10 A | |
| ● at 400 V rated value | 3 A | |
| ● at 500 V rated value | 2 A | |
| ● at 690 V rated value | 1 A | |
| Operating current at DC-12 | ||
| ● at 24 V rated value | 10 A | |
| ● at 48 V rated value | 6 A | |
| ● at 60 V rated value | 6 A | |
| ● at 110 V rated value | 3 A | |
| ● at 125 V rated value | 2 A | |
| ● at 220 V rated value | 1 A | |
| ● at 600 V rated value | 0.15 A | |
| Operating current at DC-13 | ||
| ● at 24 V rated value | 10 A | |
| ● at 48 V rated value | 2 A | |
| ● at 60 V rated value | 2 A | |
| ● at 110 V rated value | 1 A | |
| ● at 125 V rated value | 0.9 A | |
| ● at 220 V rated value | 0.3 A | |
| ● at 600 V rated value | 0.1 A | |
| Contact reliability of auxiliary contacts | 1 faulty switching per 100 million (17 V, 1 mA) | |
| UL/CSA ratings: | ||
| Full-load current (FLA) for three-phase AC motor | ||
| ● at 480 V rated value | 14 A | |
| ● at 600 V rated value | 11 A | |
| Yielded mechanical performance [hp] | ||
| ● for single-phase AC motor | ||
| — at 110/120 V rated value | 1 hp | |
| — at 230 V rated value | 2 hp | |
| ● for three-phase AC motor | ||
| — at 200/208 V rated value | 3 hp | |
| — at 220/230 V rated value | 5 hp | |
| — at 460/480 V rated value | 10 hp | |
| — at 575/600 V rated value | 10 hp | |
| Contact rating of auxiliary contacts according to UL | A600 / Q600 | |
| Short-circuit protection | ||
| Design of the fuse link | ||
| ● for short-circuit protection of the main circuit | ||
| — with type of coordination 1 required | gL/gG NH 3NA, DIAZED 5SB, NEOZED 5SE: 50 A | |
| — with type of assignment 2 required | gL/gG LV HRC 3NA, DIAZED 5SB, NEOZED 5SE: 25 A | |
| ● for short-circuit protection of the auxiliary switch required | fuse gL/gG: 10 A | |
| Installation/ mounting/ dimensions: | ||
| Mounting position | +/-180° rotation possible on vertical mounting surface; can be tilted forward and backward by +/- 22.5° on vertical mounting surface | |
| Mounting type | screw and snap-on mounting onto 35 mm standard mounting rail according to DIN EN 50022 | |
| ● Side-by-side mounting | Yes | |
| Height | 58 mm | |
| Width | 45 mm | |
| Depth | 73 mm | |
| Required spacing | ||
| ● with side-by-side mounting | ||
| — forwards | 0 mm | |
| — Backwards | 0 mm | |
| — upwards | 0 mm | |
| — downwards | 0 mm | |
| — at the side | 0 mm | |
| ● for grounded parts | ||
| — forwards | 0 mm | |
| — Backwards | 0 mm | |
| — upwards | 0 mm | |
| — at the side | 6 mm | |
| — downwards | 0 mm | |
| ● for live parts | ||
| — forwards | 0 mm | |
| — Backwards | 0 mm | |
| — upwards | 0 mm | |
| — downwards | 0 mm | |
| — at the side | 6 mm | |
| Connections/Terminals: | ||
| Type of electrical connection | ||
| ● for main current circuit | ring cable connection | |
| ● for auxiliary and control current circuit | ring cable connection | |
| Safety related data: | ||
| B10 value | ||
| ● with high demand rate acc. to SN 31920 | 1 000 000 | |
| Proportion of dangerous failures | ||
| ● with low demand rate acc. to SN 31920 | 40 % | |
| ● with high demand rate acc. to SN 31920 | 73 % | |
| Failure rate [FIT] | ||
| ● with low demand rate acc. to SN 31920 | 100 FIT | |
| Product function | ||
| ● Mirror contact acc. to IEC 60947-4-1 | Yes; with 3RH29 | |
| T1 value for proof test interval or service life acc. to IEC 61508 | 20 y | |