3RT2018-4AP61
20184
SIEMENS
1 Pcs.
Product condition, packaging, certifications and applicable manufacturer warranty terms are confirmed with the quotation.
| product brand name | SIRIUS | |
| Product designation | 3RT2 contactor | |
| General technical data: | ||
| Size of contactor | S00 | |
| Product extension | ||
| ● function module for communication | No | |
| ● Auxiliary switch | Yes | |
| Insulation voltage | ||
| ● rated value | 690 V | |
| Degree of pollution | 3 | |
| Surge voltage resistance rated value | 6 kV | |
| maximum permissible voltage for safe isolation | ||
| ● between coil and main contacts acc. to EN 60947-1 | 400 V | |
| Protection class IP | ||
| ● on the front | IP00 | |
| ● of the terminal | IP00 | |
| Shock resistance | ||
| ● at rectangular impulse | ||
| — at AC | 7,3g / 5 ms, 4,7g / 10 ms | |
| ● with sine pulse | ||
| — at AC | 11,4g / 5 ms, 7,3g / 10 ms | |
| Mechanical service life (switching cycles) | ||
| ● of contactor typical | 30 000 000 | |
| ● of the contactor with added electronics-compatible auxiliary switch block typical | 5 000 000 | |
| ● of the contactor with added auxiliary switch block typical | 10 000 000 | |
| Ambient conditions: | ||
| Installation altitude at height above sea level maximum | 2 000 m | |
| Ambient temperature | ||
| ● during operation | -25 ... +60 °C | |
| ● during storage | -55 ... +80 °C | |
| Main circuit: | ||
| Number of NO contacts for main contacts | 3 | |
| Number of NC contacts for main contacts | 0 | |
| Operating voltage | ||
| ● at AC-3 rated value maximum | 690 V | |
| Operating current | ||
| ● at AC-1 at 400 V | ||
| — at ambient temperature 40 °C rated value | 22 A | |
| ● at AC-1 | ||
| — up to 690 V at ambient temperature 40 °C rated value | 22 A | |
| — up to 690 V at ambient temperature 60 °C rated value | 20 A | |
| ● at AC-2 at 400 V rated value | 16 A | |
| ● at AC-3 | ||
| — at 400 V rated value | 16 A | |
| — at 500 V rated value | 12.4 A | |
| — at 690 V rated value | 8.9 A | |
| Connectable conductor cross-section in main circuit at AC-1 | ||
| ● at 60 °C minimum permissible | 2.5 mm² | |
| ● at 40 °C minimum permissible | 4 mm² | |
| Operating current for approx. 200000 operating cycles at AC-4 | ||
| ● at 400 V rated value | 5.5 A | |
| ● at 690 V rated value | 4.4 A | |
| Operating current | ||
| ● at 1 current path at DC-1 | ||
| — at 24 V rated value | 20 A | |
| — at 110 V rated value | 2.1 A | |
| — at 220 V rated value | 0.8 A | |
| — at 440 V rated value | 0.6 A | |
| — at 600 V rated value | 0.6 A | |
| ● with 2 current paths in series at DC-1 | ||
| — at 24 V rated value | 20 A | |
| — at 110 V rated value | 12 A | |
| — at 220 V rated value | 1.6 A | |
| — at 440 V rated value | 0.8 A | |
| — at 600 V rated value | 0.7 A | |
| ● with 3 current paths in series at DC-1 | ||
| — at 24 V rated value | 20 A | |
| — at 110 V rated value | 20 A | |
| — at 220 V rated value | 20 A | |
| — at 440 V rated value | 1.3 A | |
| — at 600 V rated value | 1 A | |
| Operating current | ||
| ● at 1 current path at DC-3 at DC-5 | ||
| — at 24 V rated value | 20 A | |
| — at 110 V rated value | 0.1 A | |
| ● with 2 current paths in series at DC-3 at DC-5 | ||
| — at 110 V rated value | 0.35 A | |
| — at 24 V rated value | 20 A | |
| ● with 3 current paths in series at DC-3 at DC-5 | ||
| — at 110 V rated value | 20 A | |
| — at 220 V rated value | 1.5 A | |
| — at 24 V rated value | 20 A | |
| — at 440 V rated value | 0.2 A | |
| — at 600 V rated value | 0.2 A | |
| Operating power | ||
| ● at AC-1 | ||
| — at 230 V rated value | 7.5 kW | |
| — at 230 V at 60 °C rated value | 7.5 kW | |
| — at 400 V rated value | 13 kW | |
| — at 400 V at 60 °C rated value | 13 kW | |
| — at 690 V rated value | 22 kW | |
| — at 690 V at 60 °C rated value | 22 kW | |
| ● at AC-2 at 400 V rated value | 7.5 kW | |
| ● at AC-3 | ||
| — at 230 V rated value | 4 kW | |
| — at 400 V rated value | 7.5 kW | |
| — at 690 V rated value | 7.5 kW | |
| Operating power for approx. 200000 operating cycles at AC-4 | ||
| ● at 400 V rated value | 2.5 kW | |
| ● at 690 V rated value | 3.5 kW | |
| Thermal short-time current limited to 10 s | 128 A | |
| Power loss [W] at AC-3 at 400 V for rated value of the operating current per conductor | 2.2 W | |
| No-load switching frequency | ||
| ● at AC | 10 000 1/h | |
| Operating frequency | ||
| ● at AC-1 maximum | 1 000 1/h | |
| ● at AC-2 maximum | 750 1/h | |
| ● at AC-3 maximum | 750 1/h | |
| ● at AC-4 maximum | 250 1/h | |
| Control circuit/ Control: | ||
| Type of voltage of the control supply voltage | AC | |
| Control supply voltage at AC | ||
| ● at 50 Hz rated value | 220 V | |
| ● at 60 Hz rated value | 240 V | |
| Operating range factor control supply voltage rated value of magnet coil at AC | ||
| ● at 50 Hz | 0.8 ... 1.1 | |
| ● at 60 Hz | 0.85 ... 1.1 | |
| Apparent pick-up power of magnet coil at AC | ||
| ● at 50 Hz | 37 V·A | |
| ● at 60 Hz | 33 V·A | |
| Inductive power factor with closing power of the coil | ||
| ● at 50 Hz | 0.8 | |
| ● at 60 Hz | 0.75 | |
| Apparent holding power of magnet coil at AC | ||
| ● at 50 Hz | 5.7 V·A | |
| ● at 60 Hz | 4.4 V·A | |
| Inductive power factor with the holding power of the coil | ||
| ● at 50 Hz | 0.25 | |
| ● at 60 Hz | 0.25 | |
| Closing delay | ||
| ● at AC | 8 ... 33 ms | |
| Opening delay | ||
| ● at AC | 4 ... 15 ms | |
| Arcing time | 10 ... 15 ms | |
| Residual current of the electronics for control with signal <0> | ||
| ● at AC at 230 V maximum permissible | 4 mA | |
| ● at DC at 24 V maximum permissible | 10 mA | |
| Auxiliary circuit: | ||
| Number of NC contacts | ||
| ● for auxiliary contacts | ||
| — instantaneous contact | 0 | |
| Number of NO contacts | ||
| ● for auxiliary contacts | ||
| — instantaneous contact | 1 | |
| Operating current at AC-12 maximum | 10 A | |
| Operating current at AC-15 | ||
| ● at 230 V rated value | 10 A | |
| ● at 400 V rated value | 3 A | |
| ● at 500 V rated value | 2 A | |
| ● at 690 V rated value | 1 A | |
| Operating current at DC-12 | ||
| ● at 24 V rated value | 10 A | |
| ● at 48 V rated value | 6 A | |
| ● at 60 V rated value | 6 A | |
| ● at 110 V rated value | 3 A | |
| ● at 125 V rated value | 2 A | |
| ● at 220 V rated value | 1 A | |
| ● at 600 V rated value | 0.15 A | |
| Operating current at DC-13 | ||
| ● at 24 V rated value | 10 A | |
| ● at 48 V rated value | 2 A | |
| ● at 60 V rated value | 2 A | |
| ● at 110 V rated value | 1 A | |
| ● at 125 V rated value | 0.9 A | |
| ● at 220 V rated value | 0.3 A | |
| ● at 600 V rated value | 0.1 A | |
| Contact reliability of auxiliary contacts | 1 faulty switching per 100 million (17 V, 1 mA) | |
| UL/CSA ratings: | ||
| Full-load current (FLA) for three-phase AC motor | ||
| ● at 480 V rated value | 14 A | |
| ● at 600 V rated value | 11 A | |
| Yielded mechanical performance [hp] | ||
| ● for single-phase AC motor | ||
| — at 110/120 V rated value | 1 hp | |
| — at 230 V rated value | 2 hp | |
| ● for three-phase AC motor | ||
| — at 200/208 V rated value | 3 hp | |
| — at 220/230 V rated value | 5 hp | |
| — at 460/480 V rated value | 10 hp | |
| — at 575/600 V rated value | 10 hp | |
| Contact rating of auxiliary contacts according to UL | A600 / Q600 | |
| Short-circuit protection | ||
| Design of the fuse link | ||
| ● for short-circuit protection of the main circuit | ||
| — with type of coordination 1 required | gL/gG NH 3NA, DIAZED 5SB, NEOZED 5SE: 50 A | |
| — with type of assignment 2 required | gL/gG LV HRC 3NA, DIAZED 5SB, NEOZED 5SE: 25 A | |
| ● for short-circuit protection of the auxiliary switch required | fuse gL/gG: 10 A | |
| Installation/ mounting/ dimensions: | ||
| Mounting position | +/-180° rotation possible on vertical mounting surface; can be tilted forward and backward by +/- 22.5° on vertical mounting surface | |
| Mounting type | screw and snap-on mounting onto 35 mm standard mounting rail according to DIN EN 50022 | |
| ● Side-by-side mounting | Yes | |
| Height | 58 mm | |
| Width | 45 mm | |
| Depth | 73 mm | |
| Required spacing | ||
| ● with side-by-side mounting | ||
| — forwards | 0 mm | |
| — Backwards | 0 mm | |
| — upwards | 0 mm | |
| — downwards | 0 mm | |
| — at the side | 0 mm | |
| ● for grounded parts | ||
| — forwards | 0 mm | |
| — Backwards | 0 mm | |
| — upwards | 0 mm | |
| — at the side | 6 mm | |
| — downwards | 0 mm | |
| ● for live parts | ||
| — forwards | 0 mm | |
| — Backwards | 0 mm | |
| — upwards | 0 mm | |
| — downwards | 0 mm | |
| — at the side | 6 mm | |
| Connections/Terminals: | ||
| Type of electrical connection | ||
| ● for main current circuit | ring cable connection | |
| ● for auxiliary and control current circuit | ring cable connection | |
| Safety related data: | ||
| B10 value | ||
| ● with high demand rate acc. to SN 31920 | 1 000 000 | |
| Proportion of dangerous failures | ||
| ● with low demand rate acc. to SN 31920 | 40 % | |
| ● with high demand rate acc. to SN 31920 | 73 % | |
| Failure rate [FIT] | ||
| ● with low demand rate acc. to SN 31920 | 100 FIT | |
| Product function | ||
| ● Mirror contact acc. to IEC 60947-4-1 | Yes; with 3RH29 | |
| T1 value for proof test interval or service life acc. to IEC 61508 | 20 y | |