Siemens 3RS2041-1GW50 temperature monitoring relay protects industrial machinery by continuously tracking thermal values from resistance sensors and tripping auxiliary contacts if pre-set thresholds are exceeded. Such relays safeguard motors, bearings, and liquid media against overheating faults.
Pricing, availability, and lead time are confirmed per enquiry through an RFQ.
- product designation: Temperature monitoring relay
- product type designation: 3RS20
- General technical data product function: temperature monitoring
- reference code according to IEC 81346-2: K
- initial value: -58 °F
- full-scale value: 932 °F
- Substance Prohibitance (Date): 05/01/2012
- error memory: Yes
- external reset: Yes
- design of the sensor connectable: PT100/1000, KTY83/84, NTC (resistance sensors)
- at 50 Hz: 24 ... 240 V
- at 60 Hz: 24 ... 240 V
- at DC: 24 ... 240 V
- supply voltage frequency for auxiliary and control circuit: 50 ... 60 Hz
- number of measuring circuits: 3
- number of NO contacts for auxiliary contacts: 1
More info
▲Technical data
Additional data
| Product | ||||||||||||||||||||||||||||||||||||||||
| Article Number (Market Facing Number) | 3RS2041-1GW50 | |||||||||||||||||||||||||||||||||||||||
| Product Description | temperature monitoring relay Pt100/1000 KTY83/84, NTC 3 sensors, 2 threshold values digitally adjustable -58 °F to 932 °F 24 - 240 V AC/DC 2 x 1 CO + 1 NO, width 45 mm screw terminal !!!phased-out product!!! the preferred successor is 3RS2600-1BW30+3RS2900-1AW30 | |||||||||||||||||||||||||||||||||||||||
| Product family | Relays, digitally adjustable for up to 3 sensors | |||||||||||||||||||||||||||||||||||||||
| Product Lifecycle (PLM) | PM400:Phase Out Started | |||||||||||||||||||||||||||||||||||||||
| PLM Effective Date | Product phase-out since: 01.10.2020 | |||||||||||||||||||||||||||||||||||||||
| Price data | ||||||||||||||||||||||||||||||||||||||||
| Region Specific PriceGroup / Headquarter Price Group | 41H / 41H | |||||||||||||||||||||||||||||||||||||||
| Surcharge for Raw Materials | None | |||||||||||||||||||||||||||||||||||||||
| Metal Factor | LAO----- | |||||||||||||||||||||||||||||||||||||||
| Delivery information | ||||||||||||||||||||||||||||||||||||||||
| Export Control Regulations | AL : N / ECCN : EAR99 | |||||||||||||||||||||||||||||||||||||||
| Standard lead time ex-works | 10 Day/Days | |||||||||||||||||||||||||||||||||||||||
| Net Weight (kg) | 0,315 Kg | |||||||||||||||||||||||||||||||||||||||
| Packaging Dimension | 53,00 x 111,50 x 105,00 | |||||||||||||||||||||||||||||||||||||||
| Package size unit of measure | MM | |||||||||||||||||||||||||||||||||||||||
| Quantity Unit | 1 Piece | |||||||||||||||||||||||||||||||||||||||
| Packaging Quantity | 1 | |||||||||||||||||||||||||||||||||||||||
| Additional Product Information | ||||||||||||||||||||||||||||||||||||||||
| EAN | 4011209565685 | |||||||||||||||||||||||||||||||||||||||
| UPC | 754554871257 | |||||||||||||||||||||||||||||||||||||||
| Commodity Code | 85364900 | |||||||||||||||||||||||||||||||||||||||
| LKZ_FDB/ CatalogID | CC-IC10 | |||||||||||||||||||||||||||||||||||||||
| Product Group | 5882 | |||||||||||||||||||||||||||||||||||||||
| Group Code | R711 | |||||||||||||||||||||||||||||||||||||||
| Country of origin | Germany | |||||||||||||||||||||||||||||||||||||||
| Compliance with the substance restrictions according to RoHS directive | Since: 01.05.2012 | |||||||||||||||||||||||||||||||||||||||
| Product class | C: products manufactured / produced to order, which cannot be reused or re-utilised or be returned against credit. | |||||||||||||||||||||||||||||||||||||||
| WEEE (2012/19/EU) Take-Back Obligation | Yes | |||||||||||||||||||||||||||||||||||||||
| REACH Art. 33 Duty to inform according to the current list of candidates |
| |||||||||||||||||||||||||||||||||||||||
| Classifications | ||||||||||||||||||||||||||||||||||||||||
| ||||||||||||||||||||||||||||||||||||||||
ETIM data
ETIM: EC001446 - Temperature monitoring relay
| Value | Unit | |
|---|---|---|
| Temperature measuring range (EF009788) | - | °C |
| Resistance measuring range (EF011955) | - | Ohm |
| Type of electric connection (EF003961) | Screw connection | |
| Rated control supply voltage Us at AC 50HZ (EF003978) | ['24', '240'] | V |
| Rated control supply voltage Us at AC 60HZ (EF003979) | ['24', '240'] | V |
| Rated control supply voltage Us at DC (EF003980) | ['24', '240'] | V |
| Voltage type for actuating (EF008242) | AC/DC | |
| With detachable clamps (EF003340) | true | |
| Number of measuring circuits (EF003425) | 3 | |
| Error registration possible (EF003423) | true | |
| External reset possible (EF003426) | true | |
| Number of contacts as normally closed contact (EF008255) | 0 | |
| Number of contacts as normally open contact (EF008256) | 1 | |
| Number of contacts as change-over contact (EF008257) | 2 | |
| Width (EF000008) | 45.0 | mm |
| Height (EF000040) | 106.0 | mm |
| Depth (EF000049) | 91.0 | mm |